Abstract.

This article describes the European DIMOND approach to defining reference levels (RLs) for radiation doses delivered to patients during two types of invasive cardiology procedures, namely coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA). Representative centres of six European countries recorded patients' doses in terms of dose-area product (DAP), fluoroscopy time and number of radiographic exposures, using X-ray equipment that has been subject to constancy testing. In addition, a DAP trigger level for cardiac procedures which should alert the operator to possible skin injury, was set to 300 Gy×cm2. The estimation of maximum skin dose was recommended in the event that a DAP trigger level was likely to be exceeded. The proposed RLs for CA and PTCA were for DAP 45 Gy×cm2 and 75 Gy×cm2, for fluoroscopy time 7.5 min and 17 min and for number of frames 1250 and 1300, respectively. The proposed RLs should be considered as a first approach to help in the optimisation of these procedures. More studies are required to establish certain "tolerances" from the proposed levels taking into account the complexity of the procedure and the patient's size.
Literature
1.
go back to reference United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) (2000) Sources and effects of ionising radiation. Report to the General Assembly, with Scientific Annexes. United Nations, New York United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) (2000) Sources and effects of ionising radiation. Report to the General Assembly, with Scientific Annexes. United Nations, New York
2.
go back to reference Padovani R, Rodella CA (2001) Staff dosimetry in interventional cardiology. Radiat Prot Dosim 94:99–103 Padovani R, Rodella CA (2001) Staff dosimetry in interventional cardiology. Radiat Prot Dosim 94:99–103
3.
go back to reference Padovani R, Malisan MR, Bernardi G, Vano E, Neofotistou V (2001) Optimisation of patient and staff exposure in interventional cardiology In: Proc Int Conf on Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–147:338–342 Padovani R, Malisan MR, Bernardi G, Vano E, Neofotistou V (2001) Optimisation of patient and staff exposure in interventional cardiology In: Proc Int Conf on Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–147:338–342
4.
go back to reference Fong RYL, Ryan E, Alonso-Arrizabalaga S (2001) A study on the annual equivalent doses received by cardiologists in a UK hospital. In: Proc Int Conf on Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–72:347–351 Fong RYL, Ryan E, Alonso-Arrizabalaga S (2001) A study on the annual equivalent doses received by cardiologists in a UK hospital. In: Proc Int Conf on Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–72:347–351
5.
go back to reference U.S. Food and Drug Administration (1994) Avoidance of serious X-ray-induced skin injuries to patients during fluoroscopically-guided procedures. Med Bull 24:7–17 U.S. Food and Drug Administration (1994) Avoidance of serious X-ray-induced skin injuries to patients during fluoroscopically-guided procedures. Med Bull 24:7–17
6.
go back to reference Faulkner K, Vano E (2001) Deterministic effects in interventional radiology. Radiat Prot Dosim 94:95–98 Faulkner K, Vano E (2001) Deterministic effects in interventional radiology. Radiat Prot Dosim 94:95–98
7.
go back to reference Vano E, Gonzalez L, Ten JI, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74:48–55PubMed Vano E, Gonzalez L, Ten JI, Fernandez JM, Guibelalde E, Macaya C (2001) Skin dose and dose-area product values for interventional cardiology procedures. Br J Radiol 74:48–55PubMed
8.
go back to reference Vano E, Goicolea J, Galvan C, Gonzalez L, Meiggs L, Ten J, Macaya C (2001) Skin radiation injuries in patients following repeated coronary angioplasty procedures. Br J Radiol 74:1023–1031PubMed Vano E, Goicolea J, Galvan C, Gonzalez L, Meiggs L, Ten J, Macaya C (2001) Skin radiation injuries in patients following repeated coronary angioplasty procedures. Br J Radiol 74:1023–1031PubMed
9.
go back to reference Stone M, Robson K, Le Boit P (1998) Subacute radiation dermatitis from fluoroscopy during coronary artery stenting. Evidence of cytotoxic lymphocyte mediated apoptosis. J Am Acad Dermatol 38:333–336PubMed Stone M, Robson K, Le Boit P (1998) Subacute radiation dermatitis from fluoroscopy during coronary artery stenting. Evidence of cytotoxic lymphocyte mediated apoptosis. J Am Acad Dermatol 38:333–336PubMed
10.
go back to reference Lobotessi H, Karoussou A, Neofotistou V, Louisi A, Tsapaki V (2001) Effective dose to a patient undergoing coronary angiography. Radiat Prot Dosim 94:173–176 Lobotessi H, Karoussou A, Neofotistou V, Louisi A, Tsapaki V (2001) Effective dose to a patient undergoing coronary angiography. Radiat Prot Dosim 94:173–176
11.
go back to reference Broadhead DA, Chapple CL, Faulkner K, Davies ML, McCallum H (1997) The impact of cardiology on the collective effective dose in the north of England. Br J Radiol 70:492–497PubMed Broadhead DA, Chapple CL, Faulkner K, Davies ML, McCallum H (1997) The impact of cardiology on the collective effective dose in the north of England. Br J Radiol 70:492–497PubMed
12.
go back to reference Leung KC, Martin CJ (1996) Effective doses for coronary angiography. Br J Radiol 69:426–431PubMed Leung KC, Martin CJ (1996) Effective doses for coronary angiography. Br J Radiol 69:426–431PubMed
13.
go back to reference Koenig TR, Wolff D, Mattler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures. Part 1. Characteristics of radiation injury. Am J Roentgenol 177:3–11 Koenig TR, Wolff D, Mattler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures. Part 1. Characteristics of radiation injury. Am J Roentgenol 177:3–11
14.
go back to reference Koenig TR, Mattler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures. Part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient. Am J Roentgenol 177:13–20 Koenig TR, Mattler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures. Part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient. Am J Roentgenol 177:13–20
15.
go back to reference Faulkner K (2001) Dose displays and record keeping. Radiat Prot Dosim 94:143–145 Faulkner K (2001) Dose displays and record keeping. Radiat Prot Dosim 94:143–145
16.
go back to reference Sajben FP (1999) Fluoroscopic-induced radiation dermatitis. Cutis 64:57–59PubMed Sajben FP (1999) Fluoroscopic-induced radiation dermatitis. Cutis 64:57–59PubMed
17.
go back to reference Hansson B, Karambatsakidou A (2000) Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures. Radiat Prot Dosim 90:141–144 Hansson B, Karambatsakidou A (2000) Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures. Radiat Prot Dosim 90:141–144
18.
go back to reference International Commission on Radiological Protection (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publ 60, Ann ICRP 21 (1–3) International Commission on Radiological Protection (1990) Recommendations of the International Commission on Radiological Protection. ICRP Publ 60, Ann ICRP 21 (1–3)
19.
go back to reference International Commission on Radiological Protection (1996) Radiological Protection and Safety in Medicine. ICRP Publ 73, Oxford, Pergamon Press, Ann ICRP 26 (2) International Commission on Radiological Protection (1996) Radiological Protection and Safety in Medicine. ICRP Publ 73, Oxford, Pergamon Press, Ann ICRP 26 (2)
20.
go back to reference International Commission on Radiological Protection (2000) Avoidance of radiation injuries from medical interventional procedures. ICRP Publ 85, Oxford, Pergamon Press, Ann ICRP 30 (2) International Commission on Radiological Protection (2000) Avoidance of radiation injuries from medical interventional procedures. ICRP Publ 85, Oxford, Pergamon Press, Ann ICRP 30 (2)
21.
go back to reference European Commission (1997) Council Directive of 30 June 1997 (97/43 /Euratom) on Health Protection of Individuals against the Dangers of Ionising Radiation in relation to Medical Exposure. Official J Eur Commun L 180:22–27 European Commission (1997) Council Directive of 30 June 1997 (97/43 /Euratom) on Health Protection of Individuals against the Dangers of Ionising Radiation in relation to Medical Exposure. Official J Eur Commun L 180:22–27
22.
go back to reference Bernardi G, Padovani R, Morocutti G, Spedicato L, Giannuleas JD, Neofotistou E, Manginas A, Goicolea JC, McNeil J, Vano E, Marzocchi A, Tsapaki V, Fioretti PM, Malone J (2001) Quality criteria for cardiac images in diagnostic and interventional cardiology. Br J Radiol 74:852–855PubMed Bernardi G, Padovani R, Morocutti G, Spedicato L, Giannuleas JD, Neofotistou E, Manginas A, Goicolea JC, McNeil J, Vano E, Marzocchi A, Tsapaki V, Fioretti PM, Malone J (2001) Quality criteria for cardiac images in diagnostic and interventional cardiology. Br J Radiol 74:852–855PubMed
23.
go back to reference Bernardi G, Padovani R, Morocutti G, Spedicato L, Giannuleas JD, Neofotistou E, Manginas A, Goicolea JC, McNeil J, Vano E (2001) A method based on DIMOND quality criteria to evaluate imaging in diagnostic and interventional cardiology. Radiat Prot Dosim 94:167–172 Bernardi G, Padovani R, Morocutti G, Spedicato L, Giannuleas JD, Neofotistou E, Manginas A, Goicolea JC, McNeil J, Vano E (2001) A method based on DIMOND quality criteria to evaluate imaging in diagnostic and interventional cardiology. Radiat Prot Dosim 94:167–172
24.
go back to reference Neofotistou V (2001) Review of patient dosimetry in cardiology. Radiat Prot Dosim 94:177–182 Neofotistou V (2001) Review of patient dosimetry in cardiology. Radiat Prot Dosim 94:177–182
25.
go back to reference Measures for optimising radiological information and dose in digital imaging and interventional radiology. European Commission. Fifth Framework Programme, 1998–2002. Programme Acronym: FP5-EAECTP C. Project Reference: FIGM-2000–00061. Project Acronym: DIMOND III. http://dbs.cordis.lu/fep/FP5/FP5_PROJl_search.html. Measures for optimising radiological information and dose in digital imaging and interventional radiology. European Commission. Fifth Framework Programme, 1998–2002. Programme Acronym: FP5-EAECTP C. Project Reference: FIGM-2000–00061. Project Acronym: DIMOND III. http://​dbs.​cordis.​lu/​fep/​FP5/​FP5_​PROJl_​search.​html.​
26.
go back to reference Toivonen M (2001) Patient dosimetry protocols in digital and interventional radiology. Radiat Prot Dosim 94:105–108 Toivonen M (2001) Patient dosimetry protocols in digital and interventional radiology. Radiat Prot Dosim 94:105–108
27.
go back to reference Vano E, Gonzalez L (2001) Approaches to establishing reference levels in interventional radiology. Radiat Prot Dosim 94:109–112 Vano E, Gonzalez L (2001) Approaches to establishing reference levels in interventional radiology. Radiat Prot Dosim 94:109–112
28.
go back to reference Faulkner K (2001) Introduction to constancy check protocols in fluoroscopic systems. Radiat Prot Dosim 94:65–68 Faulkner K (2001) Introduction to constancy check protocols in fluoroscopic systems. Radiat Prot Dosim 94:65–68
29.
go back to reference Vano E, Fernandez JM, Lopez L, Ten JI, Gonzalez L, Guibelalde E (2001) The use of constancy checks to optimise patient dose in interventional radiology systems. In: Proc Int Conf Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–196: 320–324 Vano E, Fernandez JM, Lopez L, Ten JI, Gonzalez L, Guibelalde E (2001) The use of constancy checks to optimise patient dose in interventional radiology systems. In: Proc Int Conf Radiological Protection of Patients in Diagnostic and Interventional Radiology, Nuclear Medicine and Radiotherapy, Malaga, Spain, 26–30 March, IAEA-CN-85–196: 320–324
30.
go back to reference Bernardi G, Padovani R, Morocutti G, Vano E, Malisan MR, Rinuncini M, Spedicato L, Fioretti PM (2000) Clinical and technical determinants of the complexity of percutaneous trasnluminal coronary angioplasty procedures: analysis in relation to radiation exposure parameters. Cathet Cardiovasc Interv 51:1–9CrossRef Bernardi G, Padovani R, Morocutti G, Vano E, Malisan MR, Rinuncini M, Spedicato L, Fioretti PM (2000) Clinical and technical determinants of the complexity of percutaneous trasnluminal coronary angioplasty procedures: analysis in relation to radiation exposure parameters. Cathet Cardiovasc Interv 51:1–9CrossRef
31.
go back to reference Watson L (1997) Radiation exposure during cardiology fellowship training. Health Phys 73:690–693 Watson L (1997) Radiation exposure during cardiology fellowship training. Health Phys 73:690–693
32.
go back to reference Neofotistou V (1995) Illustrating the need for education and training in radiation safety in interventional radiology. In: Proc Joint WHO/ISH Workshop on Efficacy and Radiation Safety in Interventional Radiology, Munich–Neuherberg, Germany, 9–13 October Neofotistou V (1995) Illustrating the need for education and training in radiation safety in interventional radiology. In: Proc Joint WHO/ISH Workshop on Efficacy and Radiation Safety in Interventional Radiology, Munich–Neuherberg, Germany, 9–13 October
Metadata
Title
Preliminary reference levels in interventional cardiology
Authors
V. Neofotistou
E. Vano
R. Padovani
J. Kotre
A. Dowling
M. Toivonen
S. Kottou
V. Tsapaki
S. Willis
G. Bernardi
K. Faulkner
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
European Radiology / Issue 10/2003
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-1831-x

Other articles of this Issue 10/2003

European Radiology 10/2003 Go to the issue

Calendar of events

October 2003

EuroPACS

MIR 2003