Skip to main content
Top
Published in: BMC Anesthesiology 1/2015

Open Access 01-12-2015 | Research article

Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study

Authors: Hyun Kang, Dong Rim Kim, Yong Hun Jung, Chong Wha Baek, Yong Hee Park, Jong In Oh, Won Joong Kim, Geun Joo Choi

Published in: BMC Anesthesiology | Issue 1/2015

Login to get access

Abstract

Background

The Streamlined Liner of the Pharynx Airway (SLIPA), a type of supraglottic airway, has a non-inflatable cuff that softens at body temperature to fit the laryngeal structure. We investigated whether pre-warming of SLIPA to body temperature may improve insertion parameters.

Methods

Ninety adult patients were assigned equally randomized to either Group W or Group R. Anesthesia was induced using propofol, fentanyl, and rocuronium. In Group W, the SLIPA was warmed to 37 ° C before insertion, whereas in Group R, it was inserted at room temperature. The insertion time, oropharyngeal leak pressure, postoperative throat pain, blood staining, regurgitation, number of attempts at insertion, and difficulty of insertion were compared between the two groups.

Results

The insertion time was shorter in Group W than in Group R (3.60 [3.15–4.06] s vs. 6.00 [4.45–7.50] s; P < 0.001). Oropharyngeal leak pressure from the time of insertion until 3 min after insertion was significantly higher in Group W than in Group R (P < 0.05). Postoperative throat pain, measured using the visual analog scale, was lower in Group W than in Group R (0.00 [0.00–2.50] vs. 2.00 [0.00–4.50]; P = 0.006). The difficulty of insertion was lower in Group W than in Group R (P < 0.004). There were no significant differences in terms of blood staining, regurgitation, and number of attempts.

Conclusions

Pre-warming the SLIPA to body temperature has significant benefits compared to maintaining the device at room temperature. Specifically, insertion was easier, both insertion and fitting to the laryngeal structure could be performed more quickly, and the incidence of sore throat was reduced.

Trial registration

Clinical Research Information Identifier NCT01209000
Literature
1.
go back to reference Woo YC, Cha SM, Kang H, Baek CW, Jung YH, Kim JY, et al. Less perilaryngeal gas leakage with SLIPA than with LMA-ProSeal in paralyzed patients. Can J Anaesth. 2011;58:48–54.CrossRefPubMed Woo YC, Cha SM, Kang H, Baek CW, Jung YH, Kim JY, et al. Less perilaryngeal gas leakage with SLIPA than with LMA-ProSeal in paralyzed patients. Can J Anaesth. 2011;58:48–54.CrossRefPubMed
2.
go back to reference Xu J, Zhong TD. Comparison and superiority of streamlined liner of the pharynx airway to laryngeal mask airway or tracheal tubes for gynecological laparoscopy. Zhonghua yi xue za zhi. 2010;90:49–52.PubMed Xu J, Zhong TD. Comparison and superiority of streamlined liner of the pharynx airway to laryngeal mask airway or tracheal tubes for gynecological laparoscopy. Zhonghua yi xue za zhi. 2010;90:49–52.PubMed
3.
go back to reference Choi GJ, Kang H. Safety and clinical usefulness of supraglottic airway device. J Korean Med Assoc. 2015;58: 905–914.CrossRef Choi GJ, Kang H. Safety and clinical usefulness of supraglottic airway device. J Korean Med Assoc. 2015;58: 905–914.CrossRef
4.
go back to reference Choi GJ, Kang H, Baek CW, Jung YH, Woo YC, Kim SH, et al. Comparison of streamlined liner of the pharynx airway (SLIPA™) and laryngeal mask airway: a systematic review and meta-analysis. Anaesthesia. 2015;70:613–22.CrossRefPubMed Choi GJ, Kang H, Baek CW, Jung YH, Woo YC, Kim SH, et al. Comparison of streamlined liner of the pharynx airway (SLIPA™) and laryngeal mask airway: a systematic review and meta-analysis. Anaesthesia. 2015;70:613–22.CrossRefPubMed
5.
go back to reference Ahn EJ, Kang H, Choi GJ, Yang SY, Shin HY, Baek CW, et al. Streamlined Liner of the Pharynx Airway: Randomized comparison of size selection strategies with regard to patient height vs. thyroid cartilage width. Hong Kong J Emerg Med. 2015;22:303–11. Ahn EJ, Kang H, Choi GJ, Yang SY, Shin HY, Baek CW, et al. Streamlined Liner of the Pharynx Airway: Randomized comparison of size selection strategies with regard to patient height vs. thyroid cartilage width. Hong Kong J Emerg Med. 2015;22:303–11.
6.
go back to reference Cha SM, Park S, Kang H, Baek CW, Jung YH, Cha YJ, et al. Gastric distension with SLIPA versus LMA ProSeal during laparoscopic cholecystectomy: a randomized trial. Surg Laparosc Endosc Percutan Tech. 2014;24:216–20.CrossRefPubMed Cha SM, Park S, Kang H, Baek CW, Jung YH, Cha YJ, et al. Gastric distension with SLIPA versus LMA ProSeal during laparoscopic cholecystectomy: a randomized trial. Surg Laparosc Endosc Percutan Tech. 2014;24:216–20.CrossRefPubMed
7.
go back to reference Siddiqui NT, Khan FH. Haemodynamic response to tracheal intubation via intubating laryngeal mask airway versus direct laryngoscopic tracheal intubation. J Pak Med Assoc. 2007;57:11–4.PubMed Siddiqui NT, Khan FH. Haemodynamic response to tracheal intubation via intubating laryngeal mask airway versus direct laryngoscopic tracheal intubation. J Pak Med Assoc. 2007;57:11–4.PubMed
8.
go back to reference Kahl M, Eberhart LH, Behnke H, Sänger S, Schwarz U, Vogt S, et al. Stress response to tracheal intubation in patients undergoing coronary artery surgery: direct laryngoscopy versus an intubating laryngeal mask airway. J Cardiothorac Vasc Anesth. 2004;18:275–80.CrossRefPubMed Kahl M, Eberhart LH, Behnke H, Sänger S, Schwarz U, Vogt S, et al. Stress response to tracheal intubation in patients undergoing coronary artery surgery: direct laryngoscopy versus an intubating laryngeal mask airway. J Cardiothorac Vasc Anesth. 2004;18:275–80.CrossRefPubMed
9.
go back to reference Voyagis GS. Comparison of laryngeal mask airway with endotracheal tube for airway control. Middle East J Anesthesiol. 1997;14:25–31.PubMed Voyagis GS. Comparison of laryngeal mask airway with endotracheal tube for airway control. Middle East J Anesthesiol. 1997;14:25–31.PubMed
10.
go back to reference Reinhart DJ, Simmons G. Comparison of placement of the laryngeal mask airway with endotracheal tube by paramedics and respiratory therapists. Ann Emerg Med. 1994;24:260–3.CrossRefPubMed Reinhart DJ, Simmons G. Comparison of placement of the laryngeal mask airway with endotracheal tube by paramedics and respiratory therapists. Ann Emerg Med. 1994;24:260–3.CrossRefPubMed
11.
go back to reference Yu SH, Beirne OR. Laryngeal mask airways have a lower risk of airway complications compared with endotracheal intubation: a systematic review. J Oral Maxillofac Surg. 2010;68:2359–76.CrossRefPubMed Yu SH, Beirne OR. Laryngeal mask airways have a lower risk of airway complications compared with endotracheal intubation: a systematic review. J Oral Maxillofac Surg. 2010;68:2359–76.CrossRefPubMed
12.
go back to reference Kaplan A, Crosby GJ, Bhattacharyya N. Airway protection and the laryngeal mask airway in sinus and nasal surgery. Laryngoscope. 2004;114:652–5.CrossRefPubMed Kaplan A, Crosby GJ, Bhattacharyya N. Airway protection and the laryngeal mask airway in sinus and nasal surgery. Laryngoscope. 2004;114:652–5.CrossRefPubMed
13.
go back to reference Kristensen MS, Teoh WH, Asai T. Which supraglottic airway will serve my patient best? Anaesthesia. 2014;69:1189–92.CrossRefPubMed Kristensen MS, Teoh WH, Asai T. Which supraglottic airway will serve my patient best? Anaesthesia. 2014;69:1189–92.CrossRefPubMed
14.
go back to reference Ramachandran SK, Mathis MR, Tremper KK, Shanks AM, Kheterpal S. Predictors and clinical outcomes from failed Laryngeal Mask Airway Unique: a study of 15,795 patients. Anesthesiology. 2012;116:1217–26.CrossRefPubMed Ramachandran SK, Mathis MR, Tremper KK, Shanks AM, Kheterpal S. Predictors and clinical outcomes from failed Laryngeal Mask Airway Unique: a study of 15,795 patients. Anesthesiology. 2012;116:1217–26.CrossRefPubMed
15.
go back to reference Nicholson A, Cook TM, Smith AF, Lewis SR, Reed SS. Supraglottic airway devices versus tracheal intubation for airway management during general anaesthesia in obese patients. Cochrane Database Syst Rev. 2013;9:Cd010105.PubMed Nicholson A, Cook TM, Smith AF, Lewis SR, Reed SS. Supraglottic airway devices versus tracheal intubation for airway management during general anaesthesia in obese patients. Cochrane Database Syst Rev. 2013;9:Cd010105.PubMed
16.
go back to reference Luce V, Harkouk H, Brasher C, Michelet D, Hilly J, Maesani M, et al. Supraglottic airway devices vs tracheal intubation in children: a quantitative meta-analysis of respiratory complications. Paediatr Anaesth. 2014;24:1088–98.CrossRefPubMed Luce V, Harkouk H, Brasher C, Michelet D, Hilly J, Maesani M, et al. Supraglottic airway devices vs tracheal intubation in children: a quantitative meta-analysis of respiratory complications. Paediatr Anaesth. 2014;24:1088–98.CrossRefPubMed
17.
go back to reference Bernardini A, Natalini G. Risk of pulmonary aspiration with laryngeal mask airway and tracheal tube: analysis on 65 712 procedures with positive pressure ventilation. Anaesthesia. 2009;64:1289–94.CrossRefPubMed Bernardini A, Natalini G. Risk of pulmonary aspiration with laryngeal mask airway and tracheal tube: analysis on 65 712 procedures with positive pressure ventilation. Anaesthesia. 2009;64:1289–94.CrossRefPubMed
18.
go back to reference Miller DM. A proposed classification and scoring system for supraglottic sealing airways: a brief review. Anesth Analg. 2004;99:1553–9.CrossRefPubMed Miller DM. A proposed classification and scoring system for supraglottic sealing airways: a brief review. Anesth Analg. 2004;99:1553–9.CrossRefPubMed
19.
go back to reference Miller DM, Light D. Laboratory and clinical comparisons of the Streamlined Liner of the Pharynx Airway (SLIPA) with the laryngeal mask airway. Anaesthesia. 2003;58:136–42.CrossRefPubMed Miller DM, Light D. Laboratory and clinical comparisons of the Streamlined Liner of the Pharynx Airway (SLIPA) with the laryngeal mask airway. Anaesthesia. 2003;58:136–42.CrossRefPubMed
20.
go back to reference Van Zundert TC, Brimacombe JR. Similar oropharyngeal leak pressures during anaesthesia with i-gel, LMA-ProSeal and LMA-Supreme Laryngeal Masks. Acta Anaesth Belg. 2012;63:35–41.PubMed Van Zundert TC, Brimacombe JR. Similar oropharyngeal leak pressures during anaesthesia with i-gel, LMA-ProSeal and LMA-Supreme Laryngeal Masks. Acta Anaesth Belg. 2012;63:35–41.PubMed
21.
go back to reference Lim BG, Kim KJ, Kong MH, Kim NS, Lim SH, Lee MK, et al. SLIPA may be more useful than other LMADs for difficult airway management. Can J Anaesth. 2012;59:120–1.CrossRefPubMed Lim BG, Kim KJ, Kong MH, Kim NS, Lim SH, Lee MK, et al. SLIPA may be more useful than other LMADs for difficult airway management. Can J Anaesth. 2012;59:120–1.CrossRefPubMed
22.
go back to reference Abdellatif AA, Ali MA. Comparison of streamlined liner of the pharynx airway (SLIPA) with the laryngeal mask airway Proseal for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients. Saudi J Anaesth. 2011;5:270–6.CrossRefPubMedPubMedCentral Abdellatif AA, Ali MA. Comparison of streamlined liner of the pharynx airway (SLIPA) with the laryngeal mask airway Proseal for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients. Saudi J Anaesth. 2011;5:270–6.CrossRefPubMedPubMedCentral
23.
go back to reference Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82:286–7.CrossRefPubMed Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82:286–7.CrossRefPubMed
24.
go back to reference Levitan RM, Kinkle WC. Initial anatomic investigations of the i-gel airway: a novel supraglottic airway without inflatable cuff. Anaesthesia. 2005;60:1022–6.CrossRefPubMed Levitan RM, Kinkle WC. Initial anatomic investigations of the i-gel airway: a novel supraglottic airway without inflatable cuff. Anaesthesia. 2005;60:1022–6.CrossRefPubMed
25.
go back to reference Nishiyama T, Kohno Y, Kim HJ, Shin WJ, Yang HS. The effects of prewarming the i-gel on fitting to laryngeal structure. Am J Emerg Med. 2012;30:1756–9.CrossRefPubMed Nishiyama T, Kohno Y, Kim HJ, Shin WJ, Yang HS. The effects of prewarming the i-gel on fitting to laryngeal structure. Am J Emerg Med. 2012;30:1756–9.CrossRefPubMed
26.
go back to reference Komasawa N, Nishihara I, Tatsumi S, Minami T. Prewarming of the i-gel facilitates successful insertion and ventilation efficacy with muscle relaxation: a randomized study. J Clin Anesth. 2014;26:663–7.CrossRefPubMed Komasawa N, Nishihara I, Tatsumi S, Minami T. Prewarming of the i-gel facilitates successful insertion and ventilation efficacy with muscle relaxation: a randomized study. J Clin Anesth. 2014;26:663–7.CrossRefPubMed
Metadata
Title
Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA™) improves fitting to the laryngeal structure: a randomized, double-blind study
Authors
Hyun Kang
Dong Rim Kim
Yong Hun Jung
Chong Wha Baek
Yong Hee Park
Jong In Oh
Won Joong Kim
Geun Joo Choi
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Anesthesiology / Issue 1/2015
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-015-0151-4

Other articles of this Issue 1/2015

BMC Anesthesiology 1/2015 Go to the issue