Abstract

Objectives

The purpose of this study was to evaluate the accuracy and reliability of pre-operative templating in predicting the size of femoral and tibial components and the effect of coronal deformity on templating accuracy.

Methods

This was a retrospective study of 39 pre-operative templates prepared by three different surgeons with different levels of training. The accuracy and reliability measures were evaluated by alpha and kappa coefficients of agreement. The analysis of the effect of coronal deformity on the accuracy of the template was measured by the Spearman’s correlation test.

Results

Templating was accurate for the femoral component in 28.21% of anterposterior (AP) radiographs and 35.90% of lateral radiographs. Kappa coefficients were respectively 0.111 (95% confidence interval [95%CI]: –0.19 to 0.241) and 0.200 (95%CI: –0.010 to 0.401), indicating poor agreement. Templating accuracy for the tibial component were, respectively, 37.61% and 47.01% for AP and lateral views. Kappa coefficients were 0.186 (95%CI: –0.070 to 0.379) for the AP view and 0.315 (95%CI: –0.199 to 0.431) for the lateral view, showing poor and slight agreement respectively. Considering a margin of error of ±1 sizes, the agreement level improved for all components, particularly for tibia, where agreement levels become very good. The inter-observer agreement was fair for all components, except for the lateral view of the femoral component, whose agreement was good. The Spearman correlation test showed no correlation between accuracy of templating and coronal deformity.

Conclusion

Pre-operative templating is an unreliable and inaccurate tool. There is no relation between coronal deformity and accuracy of templating.
Literature
1.
go back to reference Krackow KA (1986) Total knee arthroplasty: technical planning and surgical aspects. Instr Course Lect 35:272–282PubMed Krackow KA (1986) Total knee arthroplasty: technical planning and surgical aspects. Instr Course Lect 35:272–282PubMed
2.
go back to reference Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF (2007) A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop 464:179–183PubMed Specht LM, Levitz S, Iorio R, Healy WL, Tilzey JF (2007) A comparison of acetate and digital templating for total knee arthroplasty. Clin Orthop 464:179–183PubMed
3.
go back to reference Hitt K, Shurman JR, Greene K, McCarthy J, Moskal J, Hoeman T et al (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am 4(85–A Suppl):115–122CrossRef Hitt K, Shurman JR, Greene K, McCarthy J, Moskal J, Hoeman T et al (2003) Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am 4(85–A Suppl):115–122CrossRef
11.
go back to reference The B, Diercks RL, van Ooijen PMA, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties: a prospective study of 173 hips and 65 total knees. Acta Orthop 76:78–84CrossRefPubMed The B, Diercks RL, van Ooijen PMA, van Horn JR (2005) Comparison of analog and digital preoperative planning in total hip and knee arthroplasties: a prospective study of 173 hips and 65 total knees. Acta Orthop 76:78–84CrossRefPubMed
13.
go back to reference Arora J, Sharma S, Blyth M (2005) The role of pre-operative templating in primary total knee replacement. Knee Surg Sports Traumatol Arthrosc 13:187–189CrossRefPubMed Arora J, Sharma S, Blyth M (2005) The role of pre-operative templating in primary total knee replacement. Knee Surg Sports Traumatol Arthrosc 13:187–189CrossRefPubMed
14.
go back to reference Howcroft DWJ, Fehily MJ, Peck C, Fox A, Dillon B, Johnson DS (2006) The role of preoperative templating in total knee arthroplasty: comparison of three prostheses. Knee 13:427–429CrossRefPubMed Howcroft DWJ, Fehily MJ, Peck C, Fox A, Dillon B, Johnson DS (2006) The role of preoperative templating in total knee arthroplasty: comparison of three prostheses. Knee 13:427–429CrossRefPubMed
15.
go back to reference Heal J, Blewitt N (2002) Kinemax total knee arthroplasty: trial by template. J Arthroplast 17:90–94CrossRef Heal J, Blewitt N (2002) Kinemax total knee arthroplasty: trial by template. J Arthroplast 17:90–94CrossRef
17.
go back to reference Unnanuntana A, Arunakul M, Unnanuntana A (2007) The accuracy of preoperative templating in total knee arthroplasty. J Med Assoc Thail 90:2338–2343 Unnanuntana A, Arunakul M, Unnanuntana A (2007) The accuracy of preoperative templating in total knee arthroplasty. J Med Assoc Thail 90:2338–2343
18.
go back to reference Cohen J (1968) Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull 70:213–220CrossRefPubMed Cohen J (1968) Weighted kappa: nominal scale agreement with provision for scaled disagreement or partial credit. Psychol Bull 70:213–220CrossRefPubMed
20.
go back to reference Fleiss JL (1971) Measuring nominal scale agreement among many raters. Psychol Bull 76:378CrossRef Fleiss JL (1971) Measuring nominal scale agreement among many raters. Psychol Bull 76:378CrossRef
21.
go back to reference Hayes AF, Krippendorff K (2007) Answering the call for a standard reliability measure for coding data. Commun Methods Meas 1:77–89CrossRef Hayes AF, Krippendorff K (2007) Answering the call for a standard reliability measure for coding data. Commun Methods Meas 1:77–89CrossRef
22.
go back to reference Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed Chao EY, Neluheni EV, Hsu RW, Paley D (1994) Biomechanics of malalignment. Orthop Clin North Am 25:379–386PubMed
24.
go back to reference Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69:745–749CrossRefPubMed Moreland JR, Bassett LW, Hanker GJ (1987) Radiographic analysis of the axial alignment of the lower extremity. J Bone Joint Surg Am 69:745–749CrossRefPubMed
25.
go back to reference Cooke TD, Li J, Scudamore RA (1994) Radiographic assessment of bony contributions to knee deformity. Orthop Clin North Am 25:387–393PubMed Cooke TD, Li J, Scudamore RA (1994) Radiographic assessment of bony contributions to knee deformity. Orthop Clin North Am 25:387–393PubMed
27.
go back to reference Krackow KA (1983) Approaches to planning lower extremity alignment for total knee arthroplasty and osteotomy about the knee. Adv Orthop Surg 7:69–88 Krackow KA (1983) Approaches to planning lower extremity alignment for total knee arthroplasty and osteotomy about the knee. Adv Orthop Surg 7:69–88
Metadata
Title
Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays
Authors
Nelson Hiroyuki Miyabe Ooka
André Luiz Siqueira Campos
Vitor Mudesto da Fonseca
Luis Edmundo Oliveira Rodrigues
Edmilson Barbosa Filho
José Sérgio Franco
Rodrigo Satamini Pires e Albuquerque
Vinicius Schott Gameiro
Publication date
01-06-2018
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 6/2018
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3764-7

Other articles of this Issue 6/2018

International Orthopaedics 6/2018 Go to the issue