Skip to main content
Top
Published in: BMC Pregnancy and Childbirth 1/2016

Open Access 01-12-2016 | Research article

Pre-induction translabial ultrasound measurements in predicting mode of delivery compared to bishop score: a cross-sectional study

Authors: Soghra Khazardoost, Fahimeh Ghotbizadeh Vahdani, Sahar Latifi, Sedighe Borna, Maryam Tahani, Mohammad Ali Rezaei, Masoomeh Shafaat

Published in: BMC Pregnancy and Childbirth | Issue 1/2016

Login to get access

Abstract

Background

By increased concerns about the accuracy of the traditional methods to predict outcomes after induction of labor, developing new standards has a great clinical importance. Here, we compared the predictive value of translabial ultrasound measurements with Bishop Score to determine the suitability of induction of labor.

Methods

A homogenous population of primigravid women was recruited. Induction of labor was performed with low-dose infusion of oxytocin. Translabial ultrasound and assessment of Bishop Score were performed by two different obstetricians. Receiver–operating characteristics curves were obtained to measure area under curve and subsequently, test sensitivity of each method.

Results

One hundred women entered the investigation. Maternal body mass index was significantly higher among candidates of Cesarean section (P: 0.02). Maternal age and fetus weight, gender and occiput position were not determinants of outcomes of induction of labor. Cervical length and fetal head-pubis symphysis distance measured by translabial ultrasound had a test sensitivity of 90 and 88 %, respectively which were slightly higher than sensitivity of Bishop score (84 %).

Conclusion

This study demonstrates that translabial measurements can be a suitable alternative method to monitor labor progress with an admissible predictive value compared with Bishop Score. It is a non-invasive method which provides valuable objective measurements and can be better accepted by women when considering the painful process which is required in evaluating Bishop Score.
Literature
1.
go back to reference Maslow AS, Sweeny AL. Elective induction of labor as a risk factor for cesarean delivery among low-risk women at term. Obstet Gynecol. 2000;95(6 Pt 1):917–22.PubMed Maslow AS, Sweeny AL. Elective induction of labor as a risk factor for cesarean delivery among low-risk women at term. Obstet Gynecol. 2000;95(6 Pt 1):917–22.PubMed
2.
go back to reference Heffner LJ, Elkin E, Fretts RC. Impact of labor induction, gestational age, and maternal age on cesarean delivery rates. Obstet Gynecol. 2003;102(2):287–93.PubMed Heffner LJ, Elkin E, Fretts RC. Impact of labor induction, gestational age, and maternal age on cesarean delivery rates. Obstet Gynecol. 2003;102(2):287–93.PubMed
3.
go back to reference Eggebø TM, Heien C, Økland I, Gjessing LK, Romundstad P, Salvesen KA. Ultrasound assessment of fetal head-perineum distance before induction of labor. Ultrasound Obstet Gynecol. 2008;32(2):199–204.CrossRefPubMed Eggebø TM, Heien C, Økland I, Gjessing LK, Romundstad P, Salvesen KA. Ultrasound assessment of fetal head-perineum distance before induction of labor. Ultrasound Obstet Gynecol. 2008;32(2):199–204.CrossRefPubMed
4.
go back to reference Crowley P. Interventions for preventing or improving the outcome of delivery at or beyond term. Cochrane Database Syst Rev. 2000;2:CD000170. Crowley P. Interventions for preventing or improving the outcome of delivery at or beyond term. Cochrane Database Syst Rev. 2000;2:CD000170.
5.
go back to reference Bishop EH. Pelvic scoring for elective induction. Obstet Gynecol. 1964;24:266–8.PubMed Bishop EH. Pelvic scoring for elective induction. Obstet Gynecol. 1964;24:266–8.PubMed
6.
go back to reference Jackson GM, Ludmir J, Bader TJ. The accuracy of digital examination and ultrasound in the evaluation of cervical length. Obstet Gynecol. 1992;79(2):214–8.CrossRefPubMed Jackson GM, Ludmir J, Bader TJ. The accuracy of digital examination and ultrasound in the evaluation of cervical length. Obstet Gynecol. 1992;79(2):214–8.CrossRefPubMed
7.
go back to reference Holcomb Jr WL, Smeltzer JS. Cervical effacement: Variation and belief among clinicians. Obstet Gynecol. 1991;78(1):43–5.PubMed Holcomb Jr WL, Smeltzer JS. Cervical effacement: Variation and belief among clinicians. Obstet Gynecol. 1991;78(1):43–5.PubMed
8.
go back to reference Buchmann E. libhaber E. Interobserver agreement in intra partum estimation of fetal head station. Int J Gynecol Obstet. 2008;101(3):285–9.CrossRef Buchmann E. libhaber E. Interobserver agreement in intra partum estimation of fetal head station. Int J Gynecol Obstet. 2008;101(3):285–9.CrossRef
9.
go back to reference Dupuis O, Silveira R, Zentner A, Dittmar A, Gaucherand P, Cucherat M, et al. Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. Am J ObstetGynecol. 2005;192(3):868–74.CrossRef Dupuis O, Silveira R, Zentner A, Dittmar A, Gaucherand P, Cucherat M, et al. Birth simulator: reliability of transvaginal assessment of fetal head station as defined by the American College of Obstetricians and Gynecologists classification. Am J ObstetGynecol. 2005;192(3):868–74.CrossRef
10.
go back to reference Sadoul G, Beuret T, Lewin D. The different elements constituting the Bishop score in the induction of labor with epidural analgesia. J Gynecol Obstet Biol Reprod (Paris). 1981;10(3):269–73. Sadoul G, Beuret T, Lewin D. The different elements constituting the Bishop score in the induction of labor with epidural analgesia. J Gynecol Obstet Biol Reprod (Paris). 1981;10(3):269–73.
11.
go back to reference Faltin-Traub EF, Boulvain M, Faltin DL, Extermann P, Irion O. Reliability of the Bishop score before labor induction at term. Eur J Obstet Gynecol Reprod Biol. 2004;112(2):178–81.CrossRefPubMed Faltin-Traub EF, Boulvain M, Faltin DL, Extermann P, Irion O. Reliability of the Bishop score before labor induction at term. Eur J Obstet Gynecol Reprod Biol. 2004;112(2):178–81.CrossRefPubMed
12.
go back to reference Newman RB, Goldenberg RL, Iams JD, Meis PJ, Mercer BM, Moawad AH, et al. Preterm prediction study: comparison of the cervical score and Bishop score for prediction of spontaneous preterm delivery. Obstet Gynecol. 2008;112(3):508–15.CrossRefPubMedPubMedCentral Newman RB, Goldenberg RL, Iams JD, Meis PJ, Mercer BM, Moawad AH, et al. Preterm prediction study: comparison of the cervical score and Bishop score for prediction of spontaneous preterm delivery. Obstet Gynecol. 2008;112(3):508–15.CrossRefPubMedPubMedCentral
13.
go back to reference Rane SM, Guirgis RR, Higgins B, Nicolaides KH. Models for the prediction of successful induction of labor based on pre-induction sonographic measurement of cervical length. J Matern Fetal Neonatal Med. 2005;17(5):315–22.CrossRefPubMed Rane SM, Guirgis RR, Higgins B, Nicolaides KH. Models for the prediction of successful induction of labor based on pre-induction sonographic measurement of cervical length. J Matern Fetal Neonatal Med. 2005;17(5):315–22.CrossRefPubMed
14.
go back to reference Rane SM, Pandis GK, Guirgis RR, Nicolaides KH. Pre-induction sonographic measurement of cervical length in prolonged pregnancy: the effect of parity in the prediction of the need for Cesarean section. Ultrasound Obstet Gynecol. 2003;22(1):40–4.CrossRefPubMed Rane SM, Pandis GK, Guirgis RR, Nicolaides KH. Pre-induction sonographic measurement of cervical length in prolonged pregnancy: the effect of parity in the prediction of the need for Cesarean section. Ultrasound Obstet Gynecol. 2003;22(1):40–4.CrossRefPubMed
15.
go back to reference Rane SM, Guirgis RR, Higgins B, Nicolaides KH. The value of ultrasound in the prediction of successful induction of labor. Ultrasound Obstet Gynecol. 2004;24(5):538–49.CrossRefPubMed Rane SM, Guirgis RR, Higgins B, Nicolaides KH. The value of ultrasound in the prediction of successful induction of labor. Ultrasound Obstet Gynecol. 2004;24(5):538–49.CrossRefPubMed
16.
go back to reference Laencina AM, Sanchez FG, Gimenez JH, Martinez MS, Martinez JA, Vizcaino VM. Comparison of ultrasonographic cervical length and the Bishop score in predicting successful labor induction. Acta Obstet Gynecol Scand. 2007;86(7):799–804.CrossRef Laencina AM, Sanchez FG, Gimenez JH, Martinez MS, Martinez JA, Vizcaino VM. Comparison of ultrasonographic cervical length and the Bishop score in predicting successful labor induction. Acta Obstet Gynecol Scand. 2007;86(7):799–804.CrossRef
17.
go back to reference Rozenberg P, Chevret S, Chastang C, Ville Y. Comparison of digital and ultrasonographic examination of the cervix in predicting time interval from induction to delivery in women with a low Bishop score. BJOG. 2005;112(2):192–6.CrossRefPubMed Rozenberg P, Chevret S, Chastang C, Ville Y. Comparison of digital and ultrasonographic examination of the cervix in predicting time interval from induction to delivery in women with a low Bishop score. BJOG. 2005;112(2):192–6.CrossRefPubMed
18.
go back to reference Rozenberg P, Chevret S, Ville Y. Comparison of pre-induction ultrasonographic cervical length and Bishop score in predicting risk of cesarean section after labor induction with prostaglandins. Gynecol Obstet Fertil. 2005;33(1–2):17–22.CrossRefPubMed Rozenberg P, Chevret S, Ville Y. Comparison of pre-induction ultrasonographic cervical length and Bishop score in predicting risk of cesarean section after labor induction with prostaglandins. Gynecol Obstet Fertil. 2005;33(1–2):17–22.CrossRefPubMed
19.
go back to reference Tutschek B, Braun T, Chantraine F, Henrich W. A study of progress of labor using intrapartumtranslabial ultrasound, assessing head station, direction, and angle of descent. BJOG. 2011;118(1):62–9.CrossRefPubMed Tutschek B, Braun T, Chantraine F, Henrich W. A study of progress of labor using intrapartumtranslabial ultrasound, assessing head station, direction, and angle of descent. BJOG. 2011;118(1):62–9.CrossRefPubMed
21.
go back to reference Cunningham FG, Leveno KJ, Bloom S, Spong CY, Dashe J. Williams Obstetrics. 24th ed. 2014. p. 456. Cunningham FG, Leveno KJ, Bloom S, Spong CY, Dashe J. Williams Obstetrics. 24th ed. 2014. p. 456.
22.
go back to reference ACOG Committee on Practice Bulletins – Obstetrics. ACOG Practice Bulletin No. 107: Induction of labor. Obstet Gynecol. 2009;114(2 Pt 1):386–97. ACOG Committee on Practice Bulletins – Obstetrics. ACOG Practice Bulletin No. 107: Induction of labor. Obstet Gynecol. 2009;114(2 Pt 1):386–97.
23.
go back to reference Ho D, Lanzarone V. Measuring engagement of fetal head: validity and reproducibility of a new ultrasound technique. Ultrasound Obstet Gynecol. 2005;25(2):165–8.CrossRef Ho D, Lanzarone V. Measuring engagement of fetal head: validity and reproducibility of a new ultrasound technique. Ultrasound Obstet Gynecol. 2005;25(2):165–8.CrossRef
24.
go back to reference Eggebø TM, Gjessing LK, Heien C, Smedvig E, Økland I, Romundstad P, et al. Prediction of labor and delivery by trans perineal ultrasound in pregnancies with prelabor rupture of membranes at term. Ultrasound Obstet Gynecol. 2006;27(4):387–91.CrossRefPubMed Eggebø TM, Gjessing LK, Heien C, Smedvig E, Økland I, Romundstad P, et al. Prediction of labor and delivery by trans perineal ultrasound in pregnancies with prelabor rupture of membranes at term. Ultrasound Obstet Gynecol. 2006;27(4):387–91.CrossRefPubMed
25.
go back to reference Valentin L, Bergelin I. Intra- and interobserver reproducibility of ultrasound measurements of cervical length and width in the second and third trimesters of pregnancy. Ultrasound Obstet Gynecol. 2002;20(3):256–62.CrossRefPubMed Valentin L, Bergelin I. Intra- and interobserver reproducibility of ultrasound measurements of cervical length and width in the second and third trimesters of pregnancy. Ultrasound Obstet Gynecol. 2002;20(3):256–62.CrossRefPubMed
26.
go back to reference Tenore J. Methods for cervical ripening and induction of labor. Am Fam Physician. 2003;67(10):2123–8.PubMed Tenore J. Methods for cervical ripening and induction of labor. Am Fam Physician. 2003;67(10):2123–8.PubMed
28.
go back to reference Sherer DM, Miodovnik M, Bradley KS, Langer O. Intrapartum fetal head position II: comparison between transvaginal digital examination and trans abdominal ultrasound assessment during the second stage of labor. Ultrasound Obstet Gynecol. 2002;19(3):264–8.CrossRefPubMed Sherer DM, Miodovnik M, Bradley KS, Langer O. Intrapartum fetal head position II: comparison between transvaginal digital examination and trans abdominal ultrasound assessment during the second stage of labor. Ultrasound Obstet Gynecol. 2002;19(3):264–8.CrossRefPubMed
29.
go back to reference Sherer DM, Miodovnik M, Bradley KS, Langer O. Intrapartum fetal head position I: comparison between trans vaginal digital examination and trans abdominal ultrasound assessment during the active stage of labor. Ultrasound Obstet Gynecol. 2002;19(3):258–63.CrossRefPubMed Sherer DM, Miodovnik M, Bradley KS, Langer O. Intrapartum fetal head position I: comparison between trans vaginal digital examination and trans abdominal ultrasound assessment during the active stage of labor. Ultrasound Obstet Gynecol. 2002;19(3):258–63.CrossRefPubMed
30.
go back to reference Kreiser D, Schiff E, Lipitz S, Kayam Z, Avraham A, Achiron R. Determination of fetal occiput position by ultrasound during the second stage of labor. J Maternal fetal Med. 2001;10(4):283–6.CrossRef Kreiser D, Schiff E, Lipitz S, Kayam Z, Avraham A, Achiron R. Determination of fetal occiput position by ultrasound during the second stage of labor. J Maternal fetal Med. 2001;10(4):283–6.CrossRef
31.
go back to reference Akmal S, Tsoi E, Kametas N, Howard R, Nicolaides KH. Intrapartum sonography to determine fetal head position. J Matern Fetal Neonatal Med. 2002;12(3):172–7.CrossRefPubMed Akmal S, Tsoi E, Kametas N, Howard R, Nicolaides KH. Intrapartum sonography to determine fetal head position. J Matern Fetal Neonatal Med. 2002;12(3):172–7.CrossRefPubMed
32.
go back to reference Akmal S, Kametas N, Tsoi E, Hargreaves C, Nicolaides KH. Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery. Ultrasound Obstet Gynecol. 2003;21(5):437–40.CrossRefPubMed Akmal S, Kametas N, Tsoi E, Hargreaves C, Nicolaides KH. Comparison of transvaginal digital examination with intrapartum sonography to determine fetal head position before instrumental delivery. Ultrasound Obstet Gynecol. 2003;21(5):437–40.CrossRefPubMed
33.
go back to reference Souka AP, Haritos T, Basayiannis K, Noikokyri N, Antsaklis A. Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor. J Matern Fetal Neonatal Med. 2003;13(1):59–63.CrossRefPubMed Souka AP, Haritos T, Basayiannis K, Noikokyri N, Antsaklis A. Intrapartum ultrasound for the examination of the fetal head position in normal and obstructed labor. J Matern Fetal Neonatal Med. 2003;13(1):59–63.CrossRefPubMed
34.
go back to reference Gabriel R, Darnaud T, Chalot F, Gonzalez N, Leymarie F, Quereux C. Transvaginal sonography of the uterine cervix prior to labor induction. Ultrasound Obstet Gynecol. 2002;19(3):254–7.CrossRefPubMed Gabriel R, Darnaud T, Chalot F, Gonzalez N, Leymarie F, Quereux C. Transvaginal sonography of the uterine cervix prior to labor induction. Ultrasound Obstet Gynecol. 2002;19(3):254–7.CrossRefPubMed
35.
go back to reference Ware V, Raynor BD. Transvaginal ultrasonograpic cervical measurement as a predictor of successful labor induction. Am J Obstet Gynecol. 2000;182(5):1030–2.CrossRefPubMed Ware V, Raynor BD. Transvaginal ultrasonograpic cervical measurement as a predictor of successful labor induction. Am J Obstet Gynecol. 2000;182(5):1030–2.CrossRefPubMed
36.
go back to reference Uyar Y, Erbay G, Demir BC, Baytur Y. Comparison of the Bishop Score body mass index and Transvaginal cervical length. Arch Gynecol Obstet. 2009;280(3):357–62.CrossRefPubMed Uyar Y, Erbay G, Demir BC, Baytur Y. Comparison of the Bishop Score body mass index and Transvaginal cervical length. Arch Gynecol Obstet. 2009;280(3):357–62.CrossRefPubMed
37.
go back to reference Tan P, Cvallikkunnu N, Sugunas, Quek KF, Hassan J. Transvaginal sonographic measurement of cervical length vs. Bishop score in labor induction at term: tolerability and prediction of Cesarean delivery. Ultrasound Obstet Gynecol. 2007;29(5):568–73.CrossRefPubMed Tan P, Cvallikkunnu N, Sugunas, Quek KF, Hassan J. Transvaginal sonographic measurement of cervical length vs. Bishop score in labor induction at term: tolerability and prediction of Cesarean delivery. Ultrasound Obstet Gynecol. 2007;29(5):568–73.CrossRefPubMed
38.
go back to reference Bartha JL, Romero-Carmona R, Martinez-Del-Fresno P, Comino-Delgado R. Bishop score and transvaginal ultrasound for preinduction cervical assessment: a randomized clinical trial. Ultrasound Obstet Gynecol. 2005;25(2):155–9.CrossRefPubMed Bartha JL, Romero-Carmona R, Martinez-Del-Fresno P, Comino-Delgado R. Bishop score and transvaginal ultrasound for preinduction cervical assessment: a randomized clinical trial. Ultrasound Obstet Gynecol. 2005;25(2):155–9.CrossRefPubMed
39.
go back to reference Pandis GK, Papageorghiou AT, Ramanathan VG, Thompson MO, Nicolaides KH. Preinduction sonographic measurement of cervical length in the prediction of successful induction of labor. Ultrasound Obstet Gynecol. 2001;18(6):623–8.CrossRefPubMed Pandis GK, Papageorghiou AT, Ramanathan VG, Thompson MO, Nicolaides KH. Preinduction sonographic measurement of cervical length in the prediction of successful induction of labor. Ultrasound Obstet Gynecol. 2001;18(6):623–8.CrossRefPubMed
40.
go back to reference Gonen R, Degani S, Ron A. Prediction of successful induction of labor: comparison of transvaginal ultrasonography and the Bishop score. Eur J Ultrasound. 1998;7(3):183–7.CrossRefPubMed Gonen R, Degani S, Ron A. Prediction of successful induction of labor: comparison of transvaginal ultrasonography and the Bishop score. Eur J Ultrasound. 1998;7(3):183–7.CrossRefPubMed
41.
go back to reference Mikulandra F, Persia M, Stojnic E. When is fetal macrosomia (> or = 4500 g) an indication for caesarean section? Zentralbl Gynakol. 1996;118(8):441–7.PubMed Mikulandra F, Persia M, Stojnic E. When is fetal macrosomia (> or = 4500 g) an indication for caesarean section? Zentralbl Gynakol. 1996;118(8):441–7.PubMed
42.
go back to reference Peregrine E, O’Brien P, Omar R, Jauniaux E. Clinical and ultrasound parameters to predict the risk of cesarean delivery after induction of labor. Obstet Gynecol. 2006;107(2 Pt 1):227–33.CrossRefPubMed Peregrine E, O’Brien P, Omar R, Jauniaux E. Clinical and ultrasound parameters to predict the risk of cesarean delivery after induction of labor. Obstet Gynecol. 2006;107(2 Pt 1):227–33.CrossRefPubMed
43.
go back to reference Dietz HP, Lanzarone V, Simpson JM. Predicting operative delivery. Ultrasound Obstet Gynecol. 2006;27(4):409–15.CrossRefPubMed Dietz HP, Lanzarone V, Simpson JM. Predicting operative delivery. Ultrasound Obstet Gynecol. 2006;27(4):409–15.CrossRefPubMed
44.
go back to reference Nader R, Shek KL, Dietz HP. Predicting the outcome of induction of labor. Aust N Z J Obstet Gynaecol. 2010;50(4):329–33.CrossRefPubMed Nader R, Shek KL, Dietz HP. Predicting the outcome of induction of labor. Aust N Z J Obstet Gynaecol. 2010;50(4):329–33.CrossRefPubMed
45.
go back to reference Niino Y. The increasing cesarean rate globally and what we can do about it. Biosci Trends. 2011;5(4):139–50.CrossRefPubMed Niino Y. The increasing cesarean rate globally and what we can do about it. Biosci Trends. 2011;5(4):139–50.CrossRefPubMed
46.
go back to reference Arrieta A. Health reform and cesarean sections in the private sector: The experience of Peru. Health Policy. 2010;99(2):124–30.CrossRefPubMed Arrieta A. Health reform and cesarean sections in the private sector: The experience of Peru. Health Policy. 2010;99(2):124–30.CrossRefPubMed
47.
go back to reference Hamilton BE, Martin JA, Ventura SJ. Births: Preliminary Data for 2009. Natl Vital Stat Rep. 2010;59(3):1–14. Hamilton BE, Martin JA, Ventura SJ. Births: Preliminary Data for 2009. Natl Vital Stat Rep. 2010;59(3):1–14.
48.
go back to reference Stafford RS. Cesarean section use and source of payment: An analysis of California hospital discharge abstracts. Am J Public Health. 1990;80(3):313–5.CrossRefPubMedPubMedCentral Stafford RS. Cesarean section use and source of payment: An analysis of California hospital discharge abstracts. Am J Public Health. 1990;80(3):313–5.CrossRefPubMedPubMedCentral
Metadata
Title
Pre-induction translabial ultrasound measurements in predicting mode of delivery compared to bishop score: a cross-sectional study
Authors
Soghra Khazardoost
Fahimeh Ghotbizadeh Vahdani
Sahar Latifi
Sedighe Borna
Maryam Tahani
Mohammad Ali Rezaei
Masoomeh Shafaat
Publication date
01-12-2016
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2016
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-016-1090-x

Other articles of this Issue 1/2016

BMC Pregnancy and Childbirth 1/2016 Go to the issue