Skip to main content
Top
Published in: La radiologia medica 6/2016

01-06-2016 | HEAD, NECK AND DENTAL RADIOLOGY

Potential causes for obtaining non-diagnostic results from fine needle aspiration biopsy of thyroid nodules

Authors: Deniz Özel, Betül Duran Özel, Fuat Özkan

Published in: La radiologia medica | Issue 6/2016

Login to get access

Abstract

Purpose

The aim of this prospective study was to evaluate factors that could affect the diagnostic result success ratio of fine needle aspiration biopsy of thyroid nodules.

Materials and methods

664 patients and 696 nodules were included in this study. Demographic features of age and gender and nodule features of macrocalcification (MC) and internal content (cystic or solid predominance) were evaluated. All biopsies were performed from 1 cm or larger nodules. Three different size needles were used for comparison (22, 23 and 25 G). The patients in each group had a similar number of nodules with MC, and cystic predominance to obtain comparable results. All procedures were performed by the same radiologist, who had 4 years of experience. Histologically adequate material criteria were identified. All pathological specimens were evaluated as diagnostic or non-diagnostic by the same pathology technician. Chi-square, student’s t test and univariate analysis were used for statistical analysis.

Results

There were no statistically significant differences in demographic features and nodule properties from diagnostic results of fine needle aspiration biopsy of thyroid nodules. On the other hand, 23 G needles offered a better potential for obtaining adequate samples with a statistically significant difference.

Conclusion

Obtaining adequate material in fine needle aspiration biopsy from thyroid nodules is a challenging issue and the results are controversial. Since we obtained the best ratio with 23 G needles, we recommend interventional radiologists to use 23 G needles as far as possible and not to consider needles thicker needles than 22 G or thinner than 25 G. Nodule features and demographic features did not have an effect on obtaining adequate cytological material.
Literature
1.
go back to reference Frates MC, Benson CB, Charboneau JW, Cibas ES, Clark OH, Coleman BG et al (2005) Management of thyroid nodules detected at USG: society of radiologists in ultrasound consensus conference statement. Radiology 237:794–800CrossRefPubMed Frates MC, Benson CB, Charboneau JW, Cibas ES, Clark OH, Coleman BG et al (2005) Management of thyroid nodules detected at USG: society of radiologists in ultrasound consensus conference statement. Radiology 237:794–800CrossRefPubMed
2.
go back to reference Ezzat S, Sarti DA, Cain DR, Braunstein GD (1994) Thyroid incidentalomas. Prevalence by palpation and ultrasonography. Arch Intern Med 154:1838–1840CrossRefPubMed Ezzat S, Sarti DA, Cain DR, Braunstein GD (1994) Thyroid incidentalomas. Prevalence by palpation and ultrasonography. Arch Intern Med 154:1838–1840CrossRefPubMed
3.
go back to reference Brander A, Viikinkovski P, Nickels J, Kivisaari L (1991) Thyroid gland: US screening in a random adult population. Radiology 181:683–687CrossRefPubMed Brander A, Viikinkovski P, Nickels J, Kivisaari L (1991) Thyroid gland: US screening in a random adult population. Radiology 181:683–687CrossRefPubMed
4.
go back to reference Cai XJ, Valiyaparambath N, Nixon P, Waghorn A, Giles T, Helliwell T (2006) Ultrasound guided fine needle aspiration cytology in the diagnosis and management of thyroid nodules. Cytopathology 17:251–256CrossRefPubMed Cai XJ, Valiyaparambath N, Nixon P, Waghorn A, Giles T, Helliwell T (2006) Ultrasound guided fine needle aspiration cytology in the diagnosis and management of thyroid nodules. Cytopathology 17:251–256CrossRefPubMed
5.
go back to reference Gharib H, Goellner JR (1993) Fine-needle aspiration biopsy of the thyroid. Ann Intern Med 118:282–289CrossRefPubMed Gharib H, Goellner JR (1993) Fine-needle aspiration biopsy of the thyroid. Ann Intern Med 118:282–289CrossRefPubMed
6.
go back to reference Rosen IB, Azadian A, Walfish PG, Salem S, Lansdown E, Bedard YJ et al (1993) Ultrasound-guided fine-needle aspiration biopsy in the management of thyroid disease. Am J Surg 166:346–349CrossRefPubMed Rosen IB, Azadian A, Walfish PG, Salem S, Lansdown E, Bedard YJ et al (1993) Ultrasound-guided fine-needle aspiration biopsy in the management of thyroid disease. Am J Surg 166:346–349CrossRefPubMed
7.
go back to reference Kim J, Kim MI, Park SI, Kim BM, Kwak JY, Kim SJ et al (2008) US guided fine needle aspiration of thyroid nodules: indications, techniques, results. Radiographics 28:1869–1886 Kim J, Kim MI, Park SI, Kim BM, Kwak JY, Kim SJ et al (2008) US guided fine needle aspiration of thyroid nodules: indications, techniques, results. Radiographics 28:1869–1886
8.
go back to reference Ghorfrani M, Beckman D, Rimm DL (2006) The value of onsite adequacy assessment of thyroid fine needle aspirations is a function of operator experience. Cancer 108:110CrossRef Ghorfrani M, Beckman D, Rimm DL (2006) The value of onsite adequacy assessment of thyroid fine needle aspirations is a function of operator experience. Cancer 108:110CrossRef
9.
go back to reference Frates MC, Benson CB, Doubilet PM, Kunreuther E, Contreras M, Cibas ES et al (2006) Prevalence and distribution of carcinoma in patients with solitary and multiple thyroid nodules on sonography. J Clin Endorinol Metab 91:3411–3417CrossRef Frates MC, Benson CB, Doubilet PM, Kunreuther E, Contreras M, Cibas ES et al (2006) Prevalence and distribution of carcinoma in patients with solitary and multiple thyroid nodules on sonography. J Clin Endorinol Metab 91:3411–3417CrossRef
10.
go back to reference Rojeski MT, Gharib H (1985) Nodular thyroid disease: evaluation and management. N Engl J Med 313:428–436CrossRefPubMed Rojeski MT, Gharib H (1985) Nodular thyroid disease: evaluation and management. N Engl J Med 313:428–436CrossRefPubMed
11.
go back to reference Welker MJ, Orlov D (2003) Thyroid nodules. Am Fam Phys 67:559–566 Welker MJ, Orlov D (2003) Thyroid nodules. Am Fam Phys 67:559–566
12.
go back to reference Ucler R, Kaya C, Cuhacı N, Tam AA, Usluogulları CA, Balkan F et al (2015) Thyroid nodules with 2 prior inadequate fine needle aspiration results: effect of increasing the diameter of the needle. Endocr Pract 21(6):595CrossRefPubMed Ucler R, Kaya C, Cuhacı N, Tam AA, Usluogulları CA, Balkan F et al (2015) Thyroid nodules with 2 prior inadequate fine needle aspiration results: effect of increasing the diameter of the needle. Endocr Pract 21(6):595CrossRefPubMed
13.
go back to reference Inci MF, Ozkan F, Yuksel M, Salk I, Sahin M (2013) The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography guided fine needle aspiration biopsy of thyroid nodules. Endocrine 43:424–429CrossRefPubMed Inci MF, Ozkan F, Yuksel M, Salk I, Sahin M (2013) The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography guided fine needle aspiration biopsy of thyroid nodules. Endocrine 43:424–429CrossRefPubMed
14.
go back to reference Gumus M, Cay N, Algın O, Ipek A, Ersoy RU, Belenli O, Ugras S et al (2012) Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol 18:102–105PubMed Gumus M, Cay N, Algın O, Ipek A, Ersoy RU, Belenli O, Ugras S et al (2012) Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol 18:102–105PubMed
15.
go back to reference Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD (2001) Twenty-one gauge needles provide more cellular samples than 25 gauge needles in fine-needle aspiration biopsy of the thyroid but may not Provide increased diagnostic accuracy. Thyroid 10(11):973–976CrossRef Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD (2001) Twenty-one gauge needles provide more cellular samples than 25 gauge needles in fine-needle aspiration biopsy of the thyroid but may not Provide increased diagnostic accuracy. Thyroid 10(11):973–976CrossRef
16.
go back to reference Degirmenci B, Haktanir A, Albayrak R, Acar M, Sahin DA, Sahin O et al (2007) Sonographically guided fine needle aspiration biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol 62(8):798–803CrossRefPubMed Degirmenci B, Haktanir A, Albayrak R, Acar M, Sahin DA, Sahin O et al (2007) Sonographically guided fine needle aspiration biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol 62(8):798–803CrossRefPubMed
17.
go back to reference Aslaner R, Sahin H, Sahin M, Solakoglu DK, Erdogan N (2015) Effect of needle size on the diagnostic adequacy in fine needle aspiration of thyroid nodules. Tepecik Egit ve Arast Hast Derg 25(1):13–18 Aslaner R, Sahin H, Sahin M, Solakoglu DK, Erdogan N (2015) Effect of needle size on the diagnostic adequacy in fine needle aspiration of thyroid nodules. Tepecik Egit ve Arast Hast Derg 25(1):13–18
Metadata
Title
Potential causes for obtaining non-diagnostic results from fine needle aspiration biopsy of thyroid nodules
Authors
Deniz Özel
Betül Duran Özel
Fuat Özkan
Publication date
01-06-2016
Publisher
Springer Milan
Published in
La radiologia medica / Issue 6/2016
Print ISSN: 0033-8362
Electronic ISSN: 1826-6983
DOI
https://doi.org/10.1007/s11547-016-0624-7

Other articles of this Issue 6/2016

La radiologia medica 6/2016 Go to the issue