Skip to main content
Top
Published in: HAND 4/2015

01-12-2015

Postsurgical complications following distal radius volar plating in a diabetic population at short-term follow-up

Authors: Daniel M. Koehler, Yubo Gao, Justin J. Guan, Ericka A. Lawler, Brian D. Adams, Apurva S. Shah

Published in: HAND | Issue 4/2015

Login to get access

Abstract

Background

Diabetes mellitus increases the risk of complications following operative treatment of lower extremity fractures. There is little published data establishing the impact of diabetes following surgical treatment of upper extremity fractures. This investigation aimed to compare the incidence of short-term postsurgical complications following volar locked plating of distal radius fractures in patients with and without diabetes.

Methods

A retrospective matched cohort investigation of 33 diabetics matched 1:2 to 66 non-diabetics was performed, accounting for age, gender, fracture type, and smoking status. Electronic medical records and radiographs were reviewed for all major and minor postsurgical complications. Demographic characteristics, postoperative radiographic parameters, and final range of motion were also compared. Mean follow-up was 5.3 ± 8.2 and 5.5 ± 7.8 months for diabetics and non-diabetics, respectively.

Results

The diabetic cohort had a significantly higher overall complication rate with 24 postsurgical complications affecting 12 patients (36 %) compared to 16 complications affecting 12 patients (18 %) in the non-diabetic cohort. There was no difference in the incidence of major complications requiring operative intervention. Minor complications were significantly more common in the diabetic group and were largely accounted for by peripheral neuritis with an incidence of 30 %. Final radiographic outcomes and range of motion were similar.

Conclusions

Diabetics experienced a greater incidence of minor postsurgical complications following volar locked plating of distal radius fractures when compared to a matched, control population. The difference in outcomes is largely accounted for by the increased incidence of peripheral neuritis among diabetics. Diabetic patients should be counseled pre-operatively regarding their elevated risk profile.
Literature
1.
go back to reference Al-Rashid M, Theivendran K, Craigen MA. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br. 2006;88:1610–2.CrossRefPubMed Al-Rashid M, Theivendran K, Craigen MA. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br. 2006;88:1610–2.CrossRefPubMed
2.
go back to reference Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316–22.CrossRefPubMed Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316–22.CrossRefPubMed
3.
go back to reference Bell JS, Wollstein R, Citron ND. Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br. 1998;80:225–6.CrossRefPubMed Bell JS, Wollstein R, Citron ND. Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg Br. 1998;80:225–6.CrossRefPubMed
4.
go back to reference Bentohami A, de Burlet K, de Korte N, et al. Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur Vol. 2014;39:745–54.CrossRefPubMed Bentohami A, de Burlet K, de Korte N, et al. Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur Vol. 2014;39:745–54.CrossRefPubMed
5.
go back to reference Chung KC, Shauver MJ, Birkmeyer JD. Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am. 2009;91:1868–73.PubMedCentralCrossRefPubMed Chung KC, Shauver MJ, Birkmeyer JD. Trends in the United States in the treatment of distal radial fractures in the elderly. J Bone Joint Surg Am. 2009;91:1868–73.PubMedCentralCrossRefPubMed
6.
go back to reference Chung KC, Spilson SV. The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg Am. 2001;26:908–15.CrossRefPubMed Chung KC, Spilson SV. The frequency and epidemiology of hand and forearm fractures in the United States. J Hand Surg Am. 2001;26:908–15.CrossRefPubMed
7.
8.
go back to reference Ding I, He Z, Xiao H, et al. Risk factors for postoperative wound complications of calcaneal fractures following plate fixation. Foot Ankle Int. 2013;34:1238–44.CrossRefPubMed Ding I, He Z, Xiao H, et al. Risk factors for postoperative wound complications of calcaneal fractures following plate fixation. Foot Ankle Int. 2013;34:1238–44.CrossRefPubMed
9.
go back to reference Drobetz H, Bryant AL, Pokorny T, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg Am. 2006;31:615–22.CrossRefPubMed Drobetz H, Bryant AL, Pokorny T, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg Am. 2006;31:615–22.CrossRefPubMed
10.
go back to reference Dyck PJ, Giannini C. Pathologic alterations in the diabetic neuropathies of humans: a review. J Neuropathol Exp Neurol. 1996;55:1181–93.CrossRefPubMed Dyck PJ, Giannini C. Pathologic alterations in the diabetic neuropathies of humans: a review. J Neuropathol Exp Neurol. 1996;55:1181–93.CrossRefPubMed
11.
go back to reference Esenwein P, Sonderegger J, Gruenert J, et al. Complications following palmar plate fixation of distal radius fractures: a review of 665 cases. Arch Orthop Trauma Surg. 2013;133:1155–62.CrossRefPubMed Esenwein P, Sonderegger J, Gruenert J, et al. Complications following palmar plate fixation of distal radius fractures: a review of 665 cases. Arch Orthop Trauma Surg. 2013;133:1155–62.CrossRefPubMed
12.
go back to reference Fernandez DL, Ring D, Jupiter JB. Surgical management of delayed union and nonunion of distal radius fractures. J Hand Surg Am. 2001;26:201–9.CrossRefPubMed Fernandez DL, Ring D, Jupiter JB. Surgical management of delayed union and nonunion of distal radius fractures. J Hand Surg Am. 2001;26:201–9.CrossRefPubMed
13.
go back to reference Grindel SI, Wang M, Gerlach M, et al. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model. J Hand Surg Am. 2007;32:194–9.CrossRefPubMed Grindel SI, Wang M, Gerlach M, et al. Biomechanical comparison of fixed-angle volar plate versus fixed-angle volar plate plus fragment-specific fixation in a cadaveric distal radius fracture model. J Hand Surg Am. 2007;32:194–9.CrossRefPubMed
14.
go back to reference Hakimi M, Jungbluth P, Windolf J, et al. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg Eur Vol. 2010;35:283–8.CrossRefPubMed Hakimi M, Jungbluth P, Windolf J, et al. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg Eur Vol. 2010;35:283–8.CrossRefPubMed
15.
go back to reference Johnson NA, Cutler L, Dias JJ, et al. Complications after volar locking plate fixation of distal radius fractures. Injury. 2014;45:528–33.CrossRefPubMed Johnson NA, Cutler L, Dias JJ, et al. Complications after volar locking plate fixation of distal radius fractures. Injury. 2014;45:528–33.CrossRefPubMed
16.
go back to reference Jones KB, Maiers-Yelden KA, Marsh JL, et al. Ankle fractures in patients with diabetes mellitus. J Bone Joint Surg Br. 2005;87:489–95.CrossRefPubMed Jones KB, Maiers-Yelden KA, Marsh JL, et al. Ankle fractures in patients with diabetes mellitus. J Bone Joint Surg Br. 2005;87:489–95.CrossRefPubMed
17.
go back to reference Jupiter JB, Lipton H. The operative treatment of intraarticular fractures of the distal radius. Clin Orthop Relat Res. 1993;292:48–61.PubMed Jupiter JB, Lipton H. The operative treatment of intraarticular fractures of the distal radius. Clin Orthop Relat Res. 1993;292:48–61.PubMed
18.
go back to reference Jupiter JB, Marent-Huber M. Operative management of distal radius fractures with 2.4-millimeter locking plates: a multi-center prospective case series. J Bone Joint Surg Am. 2009;91:55–65.CrossRefPubMed Jupiter JB, Marent-Huber M. Operative management of distal radius fractures with 2.4-millimeter locking plates: a multi-center prospective case series. J Bone Joint Surg Am. 2009;91:55–65.CrossRefPubMed
19.
go back to reference Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg Am. 2006;31:1061–7.CrossRefPubMed Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg Am. 2006;31:1061–7.CrossRefPubMed
20.
go back to reference Karsidag S, Morali S, Sargin M, et al. The electrophysiological findings of subclinical neuropathy in patients with recently diagnosed type 1 diabetes mellitus. Diabetes Res Clin Pract. 2005;67:211–9.CrossRefPubMed Karsidag S, Morali S, Sargin M, et al. The electrophysiological findings of subclinical neuropathy in patients with recently diagnosed type 1 diabetes mellitus. Diabetes Res Clin Pract. 2005;67:211–9.CrossRefPubMed
21.
go back to reference Knirk JL, Jupiter JB. Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am. 1986;68:647–59.PubMed Knirk JL, Jupiter JB. Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am. 1986;68:647–59.PubMed
22.
go back to reference Koval KJ, Harrast JJ, Anglen JO, et al. Fractures of the distal part of the radius. The evolution of practice over time. Where’s the evidence? J Bone Joint Surg Am. 2008;90:1855–61.CrossRefPubMed Koval KJ, Harrast JJ, Anglen JO, et al. Fractures of the distal part of the radius. The evolution of practice over time. Where’s the evidence? J Bone Joint Surg Am. 2008;90:1855–61.CrossRefPubMed
23.
go back to reference Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium – 2007: Orthopaedic Trauma Association classification, database, and outcomes committee. J Orthop Trauma. 2007;21:S1–S133.CrossRefPubMed Marsh JL, Slongo TF, Agel J, et al. Fracture and dislocation classification compendium – 2007: Orthopaedic Trauma Association classification, database, and outcomes committee. J Orthop Trauma. 2007;21:S1–S133.CrossRefPubMed
24.
go back to reference McQueen M, Caspers J. Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br. 1988;70:649–51.PubMed McQueen M, Caspers J. Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br. 1988;70:649–51.PubMed
25.
go back to reference Miller AG, Margules A, Raikin SM. Risk factors for wound complications after ankle fracture surgery. J Bone Joint Surg Am. 2012;94:2047–52.CrossRefPubMed Miller AG, Margules A, Raikin SM. Risk factors for wound complications after ankle fracture surgery. J Bone Joint Surg Am. 2012;94:2047–52.CrossRefPubMed
27.
go back to reference Nunley JA, Rowan PR. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am. 1999;24:1279–80.CrossRefPubMed Nunley JA, Rowan PR. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am. 1999;24:1279–80.CrossRefPubMed
28.
go back to reference Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27:205–15.CrossRefPubMed Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27:205–15.CrossRefPubMed
29.
go back to reference Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am. 2004;29:96–102.CrossRefPubMed Orbay JL, Fernandez DL. Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am. 2004;29:96–102.CrossRefPubMed
30.
go back to reference Osada D, Viegas SF, Shah MA, et al. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am. 2003;28:94–104.CrossRefPubMed Osada D, Viegas SF, Shah MA, et al. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am. 2003;28:94–104.CrossRefPubMed
31.
go back to reference Ovaska MT, Makinen TJ, Madanat R, et al. Risk factors for deep surgical site infection following operative treatment of ankle fractures. J Bone Joint Surg Am. 2013;95:348–53.CrossRefPubMed Ovaska MT, Makinen TJ, Madanat R, et al. Risk factors for deep surgical site infection following operative treatment of ankle fractures. J Bone Joint Surg Am. 2013;95:348–53.CrossRefPubMed
32.
go back to reference Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73:714–9.PubMed Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73:714–9.PubMed
33.
go back to reference Ricci WM, Streubel PN, Morshed S, et al. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma. 2014;28:83–9.CrossRefPubMed Ricci WM, Streubel PN, Morshed S, et al. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma. 2014;28:83–9.CrossRefPubMed
34.
go back to reference Richard MJ, Wartinbee DA, Riboh J, et al. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am. 2011;36:1614–20.CrossRefPubMed Richard MJ, Wartinbee DA, Riboh J, et al. Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J Hand Surg Am. 2011;36:1614–20.CrossRefPubMed
35.
go back to reference Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31:359–65.CrossRefPubMed Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31:359–65.CrossRefPubMed
36.
go back to reference Rozental TD, Blazar PE, Franko OI, et al. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1837–46.CrossRefPubMed Rozental TD, Blazar PE, Franko OI, et al. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1837–46.CrossRefPubMed
37.
go back to reference Soong M, van Leerdam R, Guitton TG, et al. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36:3–9.CrossRefPubMed Soong M, van Leerdam R, Guitton TG, et al. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2011;36:3–9.CrossRefPubMed
38.
go back to reference Stewart HD, Innes AR, Burke FD. The hand complications of Colles’ fractures. J Hand Surg Br. 1985;10:103–6.CrossRefPubMed Stewart HD, Innes AR, Burke FD. The hand complications of Colles’ fractures. J Hand Surg Br. 1985;10:103–6.CrossRefPubMed
39.
go back to reference Steyers CM, Blair WF. Measuring ulnar variance: a comparison of techniques. J Hand Surg Am. 1989;14:607–12.CrossRefPubMed Steyers CM, Blair WF. Measuring ulnar variance: a comparison of techniques. J Hand Surg Am. 1989;14:607–12.CrossRefPubMed
40.
go back to reference Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am. 1994;19:325–40.CrossRefPubMed Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am. 1994;19:325–40.CrossRefPubMed
41.
go back to reference Vincent AM, Calabek B, Roberts L, et al. Biology of diabetic neuropathy. Handbook of Clin Neurol. 2013;115:591–606.CrossRef Vincent AM, Calabek B, Roberts L, et al. Biology of diabetic neuropathy. Handbook of Clin Neurol. 2013;115:591–606.CrossRef
42.
go back to reference Vincent AM, Kato K, McLean LL, et al. Sensory neurons and schwann cells respond to oxidative stress by increasing antioxidant defense mechanisms. Antioxid Redox Signal. 2009;11:425–38.PubMedCentralCrossRefPubMed Vincent AM, Kato K, McLean LL, et al. Sensory neurons and schwann cells respond to oxidative stress by increasing antioxidant defense mechanisms. Antioxid Redox Signal. 2009;11:425–38.PubMedCentralCrossRefPubMed
43.
go back to reference Ward CM, Kuhl TL, Adams BD. Early complications of volar plating of distal radius fractures and their relationship to surgeon experience. Hand (NY). 2011;6:185–9.CrossRef Ward CM, Kuhl TL, Adams BD. Early complications of volar plating of distal radius fractures and their relationship to surgeon experience. Hand (NY). 2011;6:185–9.CrossRef
44.
go back to reference Wei DH, Raizman NM, Bottino CJ, et al. Unstable distal radius fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1568–77.CrossRefPubMed Wei DH, Raizman NM, Bottino CJ, et al. Unstable distal radius fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am. 2009;91:1568–77.CrossRefPubMed
45.
go back to reference Wright TW, Horodyski M, Smith DW. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am. 2005;30:289–99.CrossRefPubMed Wright TW, Horodyski M, Smith DW. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. J Hand Surg Am. 2005;30:289–99.CrossRefPubMed
Metadata
Title
Postsurgical complications following distal radius volar plating in a diabetic population at short-term follow-up
Authors
Daniel M. Koehler
Yubo Gao
Justin J. Guan
Ericka A. Lawler
Brian D. Adams
Apurva S. Shah
Publication date
01-12-2015
Publisher
Springer US
Published in
HAND / Issue 4/2015
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-015-9777-4

Other articles of this Issue 4/2015

HAND 4/2015 Go to the issue