Abstract

Purpose

C1-C2 instability or painful osteoarthritis are recognised indications for posterior atlanto-axial fixation. In the traditional trans-articular C1-C2 screw fixation, up to 20% of patients cannot have safe placement of bilateral screws in the event of a medially located vertebral artery and a straight screw trajectory in the sagittal plane. The more recently developed C1-C2 fixation technique with individual C1 lateral mass screws and converging C2 pars screws can be employed in case of a medially located vertebral artery and has comparable biomechanical strength. This is a prospective observational study to investigate the advantages, the safety, and the drawbacks of posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws.

Methods

Twelve consecutive patients with C1-2 instability (n = 11) and painful osteoarthritis (n = 1) underwent a posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws. The average follow-up was 16 months and all patients reached the 12-month follow-up.

Findings

No hardware failure occurred in any of the patients. Correct screw placement and construct stability was found in all 12 patients (100%) at 6 and 12 months after surgery. Mean neck pain on a visual analogue scale (VAS) was 2.1 at 6 months and 2.0 at 12 months. Only transient complications were observed: one patient presented with progressive intestinal herniation through the iliac crest scar; one suffered from severe pain at the posterior iliac crest for 3 months and three patients complained of annoying pain/dysaesthesia in the C2 dermatome for 3–6 months after surgery.

Conclusion

This study confirms that posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws is a safe and effective surgical option in the treatment of atlanto-axial instability or painful osteoarthritis.
Literature
1.
go back to reference Abou Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79:820–823PubMedCrossRef Abou Madawi A, Solanki G, Casey AT, Crockard HA (1997) Variation of the groove in the axis vertebra for the vertebral artery. Implications for instrumentation. J Bone Joint Surg Br 79:820–823PubMedCrossRef
2.
go back to reference Ebraheim N, Rollins JR Jr, Xu R, Jackson WT (1996) Anatomic consideration of C2 pedicle screw placement. Spine 21:691–695PubMedCrossRef Ebraheim N, Rollins JR Jr, Xu R, Jackson WT (1996) Anatomic consideration of C2 pedicle screw placement. Spine 21:691–695PubMedCrossRef
3.
go back to reference Fiore A, Haid R, Rodts G, Subach B, Mummaneni P, Riedel C, Birch B (2002) Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series. Neurosurg Focus 12(1):E5PubMedCrossRef Fiore A, Haid R, Rodts G, Subach B, Mummaneni P, Riedel C, Birch B (2002) Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series. Neurosurg Focus 12(1):E5PubMedCrossRef
4.
go back to reference Fried LC (1973) Atlanto-axial fracture-dislocations. Failure of posterior C1 to C2 fusion. J Bone Joint Surg Br 55:490–496PubMed Fried LC (1973) Atlanto-axial fracture-dislocations. Failure of posterior C1 to C2 fusion. J Bone Joint Surg Br 55:490–496PubMed
5.
go back to reference Goel A, Desai K, Muzumdar D (2002) Atlanto-axial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(6):1351–1356PubMedCrossRef Goel A, Desai K, Muzumdar D (2002) Atlanto-axial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(6):1351–1356PubMedCrossRef
6.
go back to reference Goel A, Kulkarni G (2004) Mobile and reducible atlanto-axial dislocation in presence of occipitalised atlas: report on treatment of eight cases by direct lateral mass plate and screw fixation. Spine 29(22):E520–E523PubMedCrossRef Goel A, Kulkarni G (2004) Mobile and reducible atlanto-axial dislocation in presence of occipitalised atlas: report on treatment of eight cases by direct lateral mass plate and screw fixation. Spine 29(22):E520–E523PubMedCrossRef
7.
go back to reference Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1–2):47–53CrossRef Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129(1–2):47–53CrossRef
8.
go back to reference Grob D, Crisco JJ 3rd, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlanto-axial fixation techniques. Spine 17:480–490PubMedCrossRef Grob D, Crisco JJ 3rd, Panjabi MM, Wang P, Dvorak J (1992) Biomechanical evaluation of four different posterior atlanto-axial fixation techniques. Spine 17:480–490PubMedCrossRef
9.
go back to reference Harms J, Melcher RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod Fixation. Spine 26:2467–2471PubMedCrossRef Harms J, Melcher RP (2001) Posterior C1-C2 fusion with polyaxial screw and rod Fixation. Spine 26:2467–2471PubMedCrossRef
10.
go back to reference Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of trans-articular screw fixation. J Spinal Disord 5:464–475PubMedCrossRef Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of trans-articular screw fixation. J Spinal Disord 5:464–475PubMedCrossRef
11.
go back to reference Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomic evaluation of the atlanto-axial trans-articular screw fixation technique. J Neurosurg 86:961–968PubMed Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomic evaluation of the atlanto-axial trans-articular screw fixation technique. J Neurosurg 86:961–968PubMed
12.
go back to reference Magerl F, Seemann PS (1986) Stable posterior fusion of the atlas and axis by trans-articular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine, vol 1. Springer, New York, pp 322–327 Magerl F, Seemann PS (1986) Stable posterior fusion of the atlas and axis by trans-articular screw fixation. In: Kehr P, Weidner A (eds) Cervical spine, vol 1. Springer, New York, pp 322–327
13.
go back to reference Melcher R, Puttlitz C, Kleinstueck F, Lotz J, Harms J, Bradford D (2002) Biomechanical testing of atlanto-axial fixation techniques. Spine 27:2435–2440PubMedCrossRef Melcher R, Puttlitz C, Kleinstueck F, Lotz J, Harms J, Bradford D (2002) Biomechanical testing of atlanto-axial fixation techniques. Spine 27:2435–2440PubMedCrossRef
14.
go back to reference Menendez J, Wright N (2007) Techniques of posterior C1-C2 stabilisation. Neurosurgery 60(1 Supp1 1):S103–S111PubMed Menendez J, Wright N (2007) Techniques of posterior C1-C2 stabilisation. Neurosurgery 60(1 Supp1 1):S103–S111PubMed
15.
go back to reference Mummaneni P, Haid R (2005) Atlanto-axial fixation: overview of all techniques. Neurol India 53(4):408–415PubMedCrossRef Mummaneni P, Haid R (2005) Atlanto-axial fixation: overview of all techniques. Neurol India 53(4):408–415PubMedCrossRef
16.
go back to reference Narotam PK, Pauley SM, McGinn GJ (2003) Titanium mesh cages for cervical spine stabilisation after corpectomy: a clinical and radiological study. J Neurosurg (2 Suppl) 99:172–180PubMed Narotam PK, Pauley SM, McGinn GJ (2003) Titanium mesh cages for cervical spine stabilisation after corpectomy: a clinical and radiological study. J Neurosurg (2 Suppl) 99:172–180PubMed
17.
go back to reference Richter M, Schmidt R, Claes L, Puhl W, Wilke H (2002) Posterior atlanto-axial fixation: Biomechnaical in vitro comparison of six different techniques. Spine 27:1724–1732PubMedCrossRef Richter M, Schmidt R, Claes L, Puhl W, Wilke H (2002) Posterior atlanto-axial fixation: Biomechnaical in vitro comparison of six different techniques. Spine 27:1724–1732PubMedCrossRef
18.
go back to reference Stillerman CB, Wilson JA (1993) Atlanto-axial stabilisation with posterior trans-articular screw fixation. Technical description and report of 22 cases. Neurosurgery 32:948–955PubMedCrossRef Stillerman CB, Wilson JA (1993) Atlanto-axial stabilisation with posterior trans-articular screw fixation. Technical description and report of 22 cases. Neurosurgery 32:948–955PubMedCrossRef
19.
go back to reference Stokes JK, Villavicencio AT, Liu PC, Bray RS, Johnson JP (2002) Posterior atlanto-axial stabilisation: New alternative to C1-2 trans-articular screws. Neurosurg Focus 12:1–5CrossRef Stokes JK, Villavicencio AT, Liu PC, Bray RS, Johnson JP (2002) Posterior atlanto-axial stabilisation: New alternative to C1-2 trans-articular screws. Neurosurg Focus 12:1–5CrossRef
20.
go back to reference Stulik J, Vyskocil T, Sebesta P, Kryl J (2006) Atlanto-axial fixation using the polyaxial screw-rod system. Eur Spine J 16(4):479–484PubMedCrossRef Stulik J, Vyskocil T, Sebesta P, Kryl J (2006) Atlanto-axial fixation using the polyaxial screw-rod system. Eur Spine J 16(4):479–484PubMedCrossRef
21.
go back to reference Wright NM, Lauryssen C (1998) Vertebral artery injury in C1-2 trans-articular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88:634–640PubMedCrossRef Wright NM, Lauryssen C (1998) Vertebral artery injury in C1-2 trans-articular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88:634–640PubMedCrossRef
Metadata
Title
Posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws
Authors
M. Payer
M. Luzi
E. Tessitore
Publication date
01-03-2009
Publisher
Springer Vienna
Published in
Acta Neurochirurgica / Issue 3/2009
Print ISSN: 0001-6268
Electronic ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-009-0198-4

Other articles of this Issue 3/2009

Acta Neurochirurgica 3/2009 Go to the issue