Skip to main content
Top
Published in: European Spine Journal 9/2017

Open Access 01-09-2017 | Original Article

Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial

Authors: Mark P. Arts, Jasper F. C. Wolfs, Terry P. Corbin

Published in: European Spine Journal | Issue 9/2017

Login to get access

Abstract

Purpose

Anterior cervical discectomy with fusion is a common procedure for treating radicular arm pain. Polyetheretherketone (PEEK) plastic is a frequently used material in cages for interbody fusion. Silicon nitride is a new alternative with desirable bone compatibility and imaging characteristics. The aim of the present study is to compare silicon nitride implants with PEEK cages filled with autograft harvested from osteophytes.

Methods

The study is a prospective, randomized, blinded study of 100 patients with 2 years follow-up. The primary outcome measure was improvement in the Neck Disability Index. Other outcome measures included SF-36, VAS arm pain, VAS neck pain, assessment of recovery, operative characteristics, complications, fusion and subsidence based on dynamic X-ray and CT scan.

Results

There was no significant difference in NDI scores between the groups at 24 months follow-up. At 3 and 12 months the NDI scores were in favor of PEEK although the differences were not clinically relevant. On most follow-up moments there was no difference in VAS neck and VAS arm between both groups, and there was no statistically significant difference in patients’ perceived recovery during follow-up. Fusion rate and subsidence were similar for the two study arms and about 90% of the implants were fused at 24 months.

Conclusions

Patients treated with silicon nitride and PEEK reported similar recovery rates during follow-up. There was no significant difference in clinical outcome at 24 months. Fusion rates improved over time and are comparable between both groups.
Literature
1.
go back to reference Jacobs W, Willems PC, Kruyt M, van Limbeek J, Anderson PG, Pavlov P, Bartels R, Oner C (2011) Systematic review of anterior interbody fusion techniques for single- and double-level cervical degenerative disc disease. Spine (Phila Pa 1976) 36(14):E950–E960CrossRef Jacobs W, Willems PC, Kruyt M, van Limbeek J, Anderson PG, Pavlov P, Bartels R, Oner C (2011) Systematic review of anterior interbody fusion techniques for single- and double-level cervical degenerative disc disease. Spine (Phila Pa 1976) 36(14):E950–E960CrossRef
2.
go back to reference Cloward RB (1958) The anterior approach for removal of ruptured cervical disks. J Neurosurg 15(6):602–617CrossRefPubMed Cloward RB (1958) The anterior approach for removal of ruptured cervical disks. J Neurosurg 15(6):602–617CrossRefPubMed
3.
go back to reference Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 40-A(3):607–624CrossRefPubMed Smith GW, Robinson RA (1958) The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am 40-A(3):607–624CrossRefPubMed
4.
go back to reference Kersten RF, van Gaalen SM, de Gast A, Oner FC (2015) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15(6):1446–1460CrossRefPubMed Kersten RF, van Gaalen SM, de Gast A, Oner FC (2015) Polyetheretherketone (PEEK) cages in cervical applications: a systematic review. Spine J 15(6):1446–1460CrossRefPubMed
5.
go back to reference Celik SE, Kara A, Celik S (2007) A comparison of changes over time in cervical foraminal height after tricortical iliac graft or polyetheretherketone cage placement following anterior discectomy. J Neurosurg Spine 6(1):10–16CrossRefPubMed Celik SE, Kara A, Celik S (2007) A comparison of changes over time in cervical foraminal height after tricortical iliac graft or polyetheretherketone cage placement following anterior discectomy. J Neurosurg Spine 6(1):10–16CrossRefPubMed
6.
go back to reference Hee HT, Kundnani V (2010) Rationale for use of polyetheretherketone polymer interbody cage device in cervical spine surgery. Spine J 10(1):66–69CrossRefPubMed Hee HT, Kundnani V (2010) Rationale for use of polyetheretherketone polymer interbody cage device in cervical spine surgery. Spine J 10(1):66–69CrossRefPubMed
7.
go back to reference Kulkarni AG, Hee HT, Wong HK (2007) Solis cage (PEEK) for anterior cervical fusion: preliminary radiological results with emphasis on fusion and subsidence. Spine J 7(2):205–209CrossRefPubMed Kulkarni AG, Hee HT, Wong HK (2007) Solis cage (PEEK) for anterior cervical fusion: preliminary radiological results with emphasis on fusion and subsidence. Spine J 7(2):205–209CrossRefPubMed
8.
go back to reference Lied B, Roenning PA, Sundseth J, Helseth E (2010) Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage). BMC Surg 10:10CrossRefPubMedPubMedCentral Lied B, Roenning PA, Sundseth J, Helseth E (2010) Anterior cervical discectomy with fusion in patients with cervical disc degeneration: a prospective outcome study of 258 patients (181 fused with autologous bone graft and 77 fused with a PEEK cage). BMC Surg 10:10CrossRefPubMedPubMedCentral
9.
go back to reference Toth JM, Wang M, Estes BT, Scifert JL, Seim HB III, Turner AS (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27(3):324–334CrossRefPubMed Toth JM, Wang M, Estes BT, Scifert JL, Seim HB III, Turner AS (2006) Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 27(3):324–334CrossRefPubMed
10.
go back to reference Anderson M, Bernero J, Brodke D (2008) Medical imaging characteristics of silicon nitride ceramic: a new material for spinal arthroplasty implants. Paper presented at the 8th Annual Spine Arthroplasty Society Global Symposium on Motion Preservation Technology, Miami Anderson M, Bernero J, Brodke D (2008) Medical imaging characteristics of silicon nitride ceramic: a new material for spinal arthroplasty implants. Paper presented at the 8th Annual Spine Arthroplasty Society Global Symposium on Motion Preservation Technology, Miami
11.
go back to reference Gorth DJ, Puckett S, Ercan B, Webster TJ, Rahaman M, Bal BS (2012) Decreased bacteria activity on Si(3)N(4) surfaces compared with PEEK or titanium. Int J Nanomed 7:4829–4840 Gorth DJ, Puckett S, Ercan B, Webster TJ, Rahaman M, Bal BS (2012) Decreased bacteria activity on Si(3)N(4) surfaces compared with PEEK or titanium. Int J Nanomed 7:4829–4840
12.
go back to reference Webster TJ, Patel AA, Rahaman MN, Sonny BB (2012) Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants. Acta Biomater 8(12):4447–4454CrossRefPubMed Webster TJ, Patel AA, Rahaman MN, Sonny BB (2012) Anti-infective and osteointegration properties of silicon nitride, poly(ether ether ketone), and titanium implants. Acta Biomater 8(12):4447–4454CrossRefPubMed
13.
go back to reference Anderson MC, Olsen R (2010) Bone ingrowth into porous silicon nitride. J Biomed Mater Res A 92(4):1598–1605PubMed Anderson MC, Olsen R (2010) Bone ingrowth into porous silicon nitride. J Biomed Mater Res A 92(4):1598–1605PubMed
14.
go back to reference Arts MP, Wolfs JF, Corbin TP (2013) The CASCADE trial: effectiveness of ceramic versus PEEK cages for anterior cervical discectomy with interbody fusion; protocol of a blinded randomized controlled trial. BMC Musculoskelet Disord 14:244CrossRefPubMedPubMedCentral Arts MP, Wolfs JF, Corbin TP (2013) The CASCADE trial: effectiveness of ceramic versus PEEK cages for anterior cervical discectomy with interbody fusion; protocol of a blinded randomized controlled trial. BMC Musculoskelet Disord 14:244CrossRefPubMedPubMedCentral
15.
go back to reference Arts MP, Brand R, van den Akker E, Koes BW, Peul WC, The NEtherlands Cervical Kinematics (NECK) trial (2010) Cost-effectiveness of anterior cervical discectomy with or without interbody fusion and arthroplasty in the treatment of cervical disc herniation; a double-blind randomised multicenter study. BMC Musculoskelet Disord 11:122CrossRefPubMedPubMedCentral Arts MP, Brand R, van den Akker E, Koes BW, Peul WC, The NEtherlands Cervical Kinematics (NECK) trial (2010) Cost-effectiveness of anterior cervical discectomy with or without interbody fusion and arthroplasty in the treatment of cervical disc herniation; a double-blind randomised multicenter study. BMC Musculoskelet Disord 11:122CrossRefPubMedPubMedCentral
16.
go back to reference Bartels RH, Donk R, van der Wilt GJ, Grotenhuis JA, Venderink D (2006) Design of the PROCON trial: a prospective, randomized multi-center study comparing cervical anterior discectomy without fusion, with fusion or with arthroplasty. BMC Musculoskelet Disord 7:85CrossRefPubMedPubMedCentral Bartels RH, Donk R, van der Wilt GJ, Grotenhuis JA, Venderink D (2006) Design of the PROCON trial: a prospective, randomized multi-center study comparing cervical anterior discectomy without fusion, with fusion or with arthroplasty. BMC Musculoskelet Disord 7:85CrossRefPubMedPubMedCentral
17.
go back to reference Blackwelder WC (1982) “Proving the null hypothesis” in clinical trials. Control Clin Trials 3(4):345–353CrossRefPubMed Blackwelder WC (1982) “Proving the null hypothesis” in clinical trials. Control Clin Trials 3(4):345–353CrossRefPubMed
18.
go back to reference Carreon LY, Glassman SD, Campbell MJ, Anderson PA (2010) Neck Disability Index, short form-36 physical component summary, and pain scales for neck and arm pain: the minimum clinically important difference and substantial clinical benefit after cervical spine fusion. Spine J 10(6):469–474CrossRefPubMed Carreon LY, Glassman SD, Campbell MJ, Anderson PA (2010) Neck Disability Index, short form-36 physical component summary, and pain scales for neck and arm pain: the minimum clinically important difference and substantial clinical benefit after cervical spine fusion. Spine J 10(6):469–474CrossRefPubMed
19.
go back to reference Peolsson A (2007) Investigation of clinically important benefit of anterior cervical decompression and fusion. Eur Spine J 16(4):507–514CrossRefPubMed Peolsson A (2007) Investigation of clinically important benefit of anterior cervical decompression and fusion. Eur Spine J 16(4):507–514CrossRefPubMed
20.
go back to reference Vernon H, Mior S (1991) The Neck Disability Index: a study of reliability and validity. J Manipulative Physiol Ther 14(7):409–415PubMed Vernon H, Mior S (1991) The Neck Disability Index: a study of reliability and validity. J Manipulative Physiol Ther 14(7):409–415PubMed
21.
go back to reference Vos CJ, Verhagen AP, Koes BW (2006) Reliability and responsiveness of the Dutch version of the Neck Disability Index in patients with acute neck pain in general practice. Eur Spine J 15(11):1729–1736CrossRefPubMed Vos CJ, Verhagen AP, Koes BW (2006) Reliability and responsiveness of the Dutch version of the Neck Disability Index in patients with acute neck pain in general practice. Eur Spine J 15(11):1729–1736CrossRefPubMed
22.
go back to reference Collins SL, Moore RA, McQuay HJ (1997) The visual analogue pain intensity scale: what is moderate pain in millimetres? Pain 72(1–2):95–97CrossRefPubMed Collins SL, Moore RA, McQuay HJ (1997) The visual analogue pain intensity scale: what is moderate pain in millimetres? Pain 72(1–2):95–97CrossRefPubMed
23.
go back to reference Bombardier C (2000) Outcome assessments in the evaluation of treatment of spinal disorders: summary and general recommendations. Spine (Phila Pa 1976) 25(24):3100–3103CrossRef Bombardier C (2000) Outcome assessments in the evaluation of treatment of spinal disorders: summary and general recommendations. Spine (Phila Pa 1976) 25(24):3100–3103CrossRef
24.
go back to reference Brazier JE, Harper R, Jones NM, O’Cathain A, Thomas KJ, Usherwood T, Westlake L (1992) Validating the SF-36 health survey questionnaire: new outcome measure for primary care. BMJ 305(6846):160–164CrossRefPubMedPubMedCentral Brazier JE, Harper R, Jones NM, O’Cathain A, Thomas KJ, Usherwood T, Westlake L (1992) Validating the SF-36 health survey questionnaire: new outcome measure for primary care. BMJ 305(6846):160–164CrossRefPubMedPubMedCentral
25.
go back to reference Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30(6):473–483CrossRefPubMed Ware JE Jr, Sherbourne CD (1992) The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care 30(6):473–483CrossRefPubMed
26.
go back to reference Taylor M, Hipp JA, Gertzbein SD, Gopinath S, Reitman CA (2007) Observer agreement in assessing flexion-extension X-rays of the cervical spine, with and without the use of quantitative measurements of intervertebral motion. Spine J 7(6):654–658CrossRefPubMedPubMedCentral Taylor M, Hipp JA, Gertzbein SD, Gopinath S, Reitman CA (2007) Observer agreement in assessing flexion-extension X-rays of the cervical spine, with and without the use of quantitative measurements of intervertebral motion. Spine J 7(6):654–658CrossRefPubMedPubMedCentral
27.
go back to reference Epstein NE (2012) Iliac crest autograft versus alternative constructs for anterior cervical spine surgery: pros, cons, and costs. Surg Neurol Int 3(Suppl 3):S143–S156CrossRefPubMedPubMedCentral Epstein NE (2012) Iliac crest autograft versus alternative constructs for anterior cervical spine surgery: pros, cons, and costs. Surg Neurol Int 3(Suppl 3):S143–S156CrossRefPubMedPubMedCentral
28.
go back to reference Farrokhi MR, Nikoo Z, Gholami M, Hosseini K (2017) Comparison between acrylic cage and polyetheretherketone (PEEK) cage in single-level anterior cervical discectomy and fusion: a randomized clinical trial. Clin Spine Surg 30:34–46 Farrokhi MR, Nikoo Z, Gholami M, Hosseini K (2017) Comparison between acrylic cage and polyetheretherketone (PEEK) cage in single-level anterior cervical discectomy and fusion: a randomized clinical trial. Clin Spine Surg 30:34–46
29.
go back to reference Shiban E, Gapon K, Wostrack M, Meyer B, Lehmberg J (2016) Clinical and radiological outcome after anterior cervical discectomy and fusion with stand-alone empty polyetheretherketone (PEEK) cages. Acta Neurochir (Wien) 158(2):349–355CrossRef Shiban E, Gapon K, Wostrack M, Meyer B, Lehmberg J (2016) Clinical and radiological outcome after anterior cervical discectomy and fusion with stand-alone empty polyetheretherketone (PEEK) cages. Acta Neurochir (Wien) 158(2):349–355CrossRef
30.
go back to reference Chagas H, Domingues F, Aversa A, Vidal Fonseca AL, de Souza JM (2005) Cervical spondylotic myelopathy: 10 years of prospective outcome analysis of anterior decompression and fusion. Surg Neurol 64(Suppl 1):S1–S5PubMed Chagas H, Domingues F, Aversa A, Vidal Fonseca AL, de Souza JM (2005) Cervical spondylotic myelopathy: 10 years of prospective outcome analysis of anterior decompression and fusion. Surg Neurol 64(Suppl 1):S1–S5PubMed
31.
go back to reference Chotai S, Parker SL, Sielatycki JA, Sivaganesan A, Kay HL, Wick JB, McGirt MJ, Devin CJ (2016) Impact of old age on patient-report outcomes and cost utility for anterior cervical discectomy and fusion surgery for degenerative spine disease. Eur Spine J. doi:10.1007/s00586-016-4835-3 Chotai S, Parker SL, Sielatycki JA, Sivaganesan A, Kay HL, Wick JB, McGirt MJ, Devin CJ (2016) Impact of old age on patient-report outcomes and cost utility for anterior cervical discectomy and fusion surgery for degenerative spine disease. Eur Spine J. doi:10.​1007/​s00586-016-4835-3
32.
go back to reference Pechlivanis I, Thuring T, Brenke C, Seiz M, Thome C, Barth M, Harders A, Schmieder K (2011) Non-fusion rates in anterior cervical discectomy and implantation of empty polyetheretherketone cages. Spine (Phila Pa 1976) 36(1):15–20CrossRef Pechlivanis I, Thuring T, Brenke C, Seiz M, Thome C, Barth M, Harders A, Schmieder K (2011) Non-fusion rates in anterior cervical discectomy and implantation of empty polyetheretherketone cages. Spine (Phila Pa 1976) 36(1):15–20CrossRef
33.
go back to reference Kasliwal MK, Baskin DS, Traynelis VC (2013) Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multicenter clinical study. J Spinal Disord Tech 26(5):239–245CrossRefPubMed Kasliwal MK, Baskin DS, Traynelis VC (2013) Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multicenter clinical study. J Spinal Disord Tech 26(5):239–245CrossRefPubMed
Metadata
Title
Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial
Authors
Mark P. Arts
Jasper F. C. Wolfs
Terry P. Corbin
Publication date
01-09-2017
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 9/2017
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-017-5079-6

Other articles of this Issue 9/2017

European Spine Journal 9/2017 Go to the issue