Skip to main content
Top
Published in: Journal of Cardiovascular Magnetic Resonance 1/2014

Open Access 01-12-2014 | Research

Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power

Authors: Antonio de Marvao, Timothy JW Dawes, Wenzhe Shi, Christopher Minas, Niall G Keenan, Tamara Diamond, Giuliana Durighel, Giovanni Montana, Daniel Rueckert, Stuart A Cook, Declan P O’Regan

Published in: Journal of Cardiovascular Magnetic Resonance | Issue 1/2014

Login to get access

Abstract

Background

Cardiac phenotypes, such as left ventricular (LV) mass, demonstrate high heritability although most genes associated with these complex traits remain unidentified. Genome-wide association studies (GWAS) have relied on conventional 2D cardiovascular magnetic resonance (CMR) as the gold-standard for phenotyping. However this technique is insensitive to the regional variations in wall thickness which are often associated with left ventricular hypertrophy and require large cohorts to reach significance. Here we test whether automated cardiac phenotyping using high spatial resolution CMR atlases can achieve improved precision for mapping wall thickness in healthy populations and whether smaller sample sizes are required compared to conventional methods.

Methods

LV short-axis cine images were acquired in 138 healthy volunteers using standard 2D imaging and 3D high spatial resolution CMR. A multi-atlas technique was used to segment and co-register each image. The agreement between methods for end-diastolic volume and mass was made using Bland-Altman analysis in 20 subjects. The 3D and 2D segmentations of the LV were compared to manual labeling by the proportion of concordant voxels (Dice coefficient) and the distances separating corresponding points. Parametric and nonparametric data were analysed with paired t-tests and Wilcoxon signed-rank test respectively. Voxelwise power calculations used the interstudy variances of wall thickness.

Results

The 3D volumetric measurements showed no bias compared to 2D imaging. The segmented 3D images were more accurate than 2D images for defining the epicardium (Dice: 0.95 vs 0.93, P < 0.001; mean error 1.3 mm vs 2.2 mm, P < 0.001) and endocardium (Dice 0.95 vs 0.93, P < 0.001; mean error 1.1 mm vs 2.0 mm, P < 0.001). The 3D technique resulted in significant differences in wall thickness assessment at the base, septum and apex of the LV compared to 2D (P < 0.001). Fewer subjects were required for 3D imaging to detect a 1 mm difference in wall thickness (72 vs 56, P < 0.001).

Conclusions

High spatial resolution CMR with automated phenotyping provides greater power for mapping wall thickness than conventional 2D imaging and enables a reduction in the sample size required for studies of environmental and genetic determinants of LV wall thickness.
Appendix
Available only for authorised users
Literature
1.
go back to reference Post WS, Larson MG, Myers RH, Galderisi M, Levy D: Heritability of left ventricular mass: the Framingham Heart Study. Hypertension. 1997, 30: 1025-1028. 10.1161/01.HYP.30.5.1025.CrossRefPubMed Post WS, Larson MG, Myers RH, Galderisi M, Levy D: Heritability of left ventricular mass: the Framingham Heart Study. Hypertension. 1997, 30: 1025-1028. 10.1161/01.HYP.30.5.1025.CrossRefPubMed
3.
go back to reference Lorell BH, Carabello BA: Left ventricular hypertrophy: pathogenesis, detection, and prognosis. Circulation. 2000, 102: 470-479. 10.1161/01.CIR.102.4.470.CrossRefPubMed Lorell BH, Carabello BA: Left ventricular hypertrophy: pathogenesis, detection, and prognosis. Circulation. 2000, 102: 470-479. 10.1161/01.CIR.102.4.470.CrossRefPubMed
4.
go back to reference Vasan RS, Glazer NL, Felix JF, Lieb W, Wild PS, Felix SB, Watzinger N, Larson MG, Smith NL, Dehghan A, et al: Genetic variants associated with cardiac structure and function: a meta-analysis and replication of genome-wide association data. JAMA. 2009, 302: 168-178. 10.1001/jama.2009.978-a.PubMedCentralCrossRefPubMed Vasan RS, Glazer NL, Felix JF, Lieb W, Wild PS, Felix SB, Watzinger N, Larson MG, Smith NL, Dehghan A, et al: Genetic variants associated with cardiac structure and function: a meta-analysis and replication of genome-wide association data. JAMA. 2009, 302: 168-178. 10.1001/jama.2009.978-a.PubMedCentralCrossRefPubMed
5.
go back to reference Stein JL, Hua X, Lee S, Ho AJ, Leow AD, Toga AW, Saykin AJ, Shen L, Foroud T, Pankratz N, et al: Voxelwise genome-wide association study (vGWAS). Neuroimage. 2010, 53: 1160-1174. 10.1016/j.neuroimage.2010.02.032.PubMedCentralCrossRefPubMed Stein JL, Hua X, Lee S, Ho AJ, Leow AD, Toga AW, Saykin AJ, Shen L, Foroud T, Pankratz N, et al: Voxelwise genome-wide association study (vGWAS). Neuroimage. 2010, 53: 1160-1174. 10.1016/j.neuroimage.2010.02.032.PubMedCentralCrossRefPubMed
6.
go back to reference Hua X, Lee S, Yanovsky I, Leow AD, Chou YY, Ho AJ, Gutman B, Toga AW, Jack CR, Bernstein MA, et al: Optimizing power to track brain degeneration in Alzheimer’s disease and mild cognitive impairment with tensor-based morphometry: an ADNI study of 515 subjects. Neuroimage. 2009, 48: 668-681. 10.1016/j.neuroimage.2009.07.011.PubMedCentralCrossRefPubMed Hua X, Lee S, Yanovsky I, Leow AD, Chou YY, Ho AJ, Gutman B, Toga AW, Jack CR, Bernstein MA, et al: Optimizing power to track brain degeneration in Alzheimer’s disease and mild cognitive impairment with tensor-based morphometry: an ADNI study of 515 subjects. Neuroimage. 2009, 48: 668-681. 10.1016/j.neuroimage.2009.07.011.PubMedCentralCrossRefPubMed
7.
go back to reference Vounou M, Nichols TE, Montana G: Discovering genetic associations with high-dimensional neuroimaging phenotypes: A sparse reduced-rank regression approach. Neuroimage. 2010, 53: 1147-1159. 10.1016/j.neuroimage.2010.07.002.CrossRefPubMed Vounou M, Nichols TE, Montana G: Discovering genetic associations with high-dimensional neuroimaging phenotypes: A sparse reduced-rank regression approach. Neuroimage. 2010, 53: 1147-1159. 10.1016/j.neuroimage.2010.07.002.CrossRefPubMed
8.
go back to reference Vounou M, Janousova E, Wolz R, Stein JL, Thompson PM, Rueckert D, Montana G: Sparse reduced-rank regression detects genetic associations with voxel-wise longitudinal phenotypes in Alzheimer’s disease. Neuroimage. 2012, 60: 700-716. 10.1016/j.neuroimage.2011.12.029.PubMedCentralCrossRefPubMed Vounou M, Janousova E, Wolz R, Stein JL, Thompson PM, Rueckert D, Montana G: Sparse reduced-rank regression detects genetic associations with voxel-wise longitudinal phenotypes in Alzheimer’s disease. Neuroimage. 2012, 60: 700-716. 10.1016/j.neuroimage.2011.12.029.PubMedCentralCrossRefPubMed
9.
go back to reference Shen L, Kim S, Risacher SL, Nho K, Swaminathan S, West JD, Foroud T, Pankratz N, Moore JH, Sloan CD, et al: Whole genome association study of brain-wide imaging phenotypes for identifying quantitative trait loci in MCI and AD: A study of the ADNI cohort. Neuroimage. 2010, 53: 1051-1063. 10.1016/j.neuroimage.2010.01.042.PubMedCentralCrossRefPubMed Shen L, Kim S, Risacher SL, Nho K, Swaminathan S, West JD, Foroud T, Pankratz N, Moore JH, Sloan CD, et al: Whole genome association study of brain-wide imaging phenotypes for identifying quantitative trait loci in MCI and AD: A study of the ADNI cohort. Neuroimage. 2010, 53: 1051-1063. 10.1016/j.neuroimage.2010.01.042.PubMedCentralCrossRefPubMed
10.
go back to reference Young AA, Frangi AF: Computational cardiac atlases: from patient to population and back. Exp Physiol. 2009, 94: 578-596. 10.1113/expphysiol.2008.044081.CrossRefPubMed Young AA, Frangi AF: Computational cardiac atlases: from patient to population and back. Exp Physiol. 2009, 94: 578-596. 10.1113/expphysiol.2008.044081.CrossRefPubMed
11.
go back to reference Fonseca CG, Backhaus M, Bluemke DA, Britten RD, Chung JD, Cowan BR, Dinov ID, Finn JP, Hunter PJ, Kadish AH, et al: The Cardiac Atlas Project-an imaging database for computational modeling and statistical atlases of the heart. Bioinformatics. 2011, 27: 2288-2295. 10.1093/bioinformatics/btr360.PubMedCentralCrossRefPubMed Fonseca CG, Backhaus M, Bluemke DA, Britten RD, Chung JD, Cowan BR, Dinov ID, Finn JP, Hunter PJ, Kadish AH, et al: The Cardiac Atlas Project-an imaging database for computational modeling and statistical atlases of the heart. Bioinformatics. 2011, 27: 2288-2295. 10.1093/bioinformatics/btr360.PubMedCentralCrossRefPubMed
12.
go back to reference Petitjean C, Dacher J-N: A review of segmentation methods in short axis cardiac MR images. Med Image Anal. 2011, 15: 169-184. 10.1016/j.media.2010.12.004.CrossRefPubMed Petitjean C, Dacher J-N: A review of segmentation methods in short axis cardiac MR images. Med Image Anal. 2011, 15: 169-184. 10.1016/j.media.2010.12.004.CrossRefPubMed
13.
go back to reference Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E: Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols. J Cardiovasc Magn Reson. 2008, 10: 35-10.1186/1532-429X-10-35.PubMedCentralCrossRefPubMed Kramer CM, Barkhausen J, Flamm SD, Kim RJ, Nagel E: Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols. J Cardiovasc Magn Reson. 2008, 10: 35-10.1186/1532-429X-10-35.PubMedCentralCrossRefPubMed
14.
go back to reference Mascarenhas NB, Muthupillai R, Cheong B, Pereyra M, Flamm SD: Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold. AJR Am J Roentgenol. 2006, 187: 1235-1239. 10.2214/AJR.06.0169.CrossRefPubMed Mascarenhas NB, Muthupillai R, Cheong B, Pereyra M, Flamm SD: Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold. AJR Am J Roentgenol. 2006, 187: 1235-1239. 10.2214/AJR.06.0169.CrossRefPubMed
15.
go back to reference Rochitte CE, Azevedo CF, Rosario MA, Siqueira MH, Monsao V, Saranathan M, Foo TK, Filho RK, Cerri GG, Ramires JA: Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique. Open Cardiovasc Med J. 2011, 5: 90-98. 10.2174/1874192401105010090.PubMedCentralCrossRefPubMed Rochitte CE, Azevedo CF, Rosario MA, Siqueira MH, Monsao V, Saranathan M, Foo TK, Filho RK, Cerri GG, Ramires JA: Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique. Open Cardiovasc Med J. 2011, 5: 90-98. 10.2174/1874192401105010090.PubMedCentralCrossRefPubMed
16.
go back to reference Hamdan A, Kelle S, Schnackenburg B, Wellnhofer E, Fleck E, Nagel E: Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla. J Magn Reson Imaging. 2008, 27: 1028-1036. 10.1002/jmri.21332.CrossRefPubMed Hamdan A, Kelle S, Schnackenburg B, Wellnhofer E, Fleck E, Nagel E: Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla. J Magn Reson Imaging. 2008, 27: 1028-1036. 10.1002/jmri.21332.CrossRefPubMed
17.
go back to reference Sievers B, Schrader S, Rehwald W, Hunold P, Barkhausen J, Erbel R: Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations. Acta Cardiol. 2011, 66: 349-357.PubMed Sievers B, Schrader S, Rehwald W, Hunold P, Barkhausen J, Erbel R: Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations. Acta Cardiol. 2011, 66: 349-357.PubMed
18.
go back to reference Parish V, Hussain T, Beerbaum P, Greil G, Nagel E, Razavi R, Schaeffter T, Uribe S: Single breath-hold assessment of ventricular volumes using 32-channel coil technology and an extracellular contrast agent. J Magn Reson Imaging. 2010, 31: 838-844. 10.1002/jmri.22061.CrossRefPubMed Parish V, Hussain T, Beerbaum P, Greil G, Nagel E, Razavi R, Schaeffter T, Uribe S: Single breath-hold assessment of ventricular volumes using 32-channel coil technology and an extracellular contrast agent. J Magn Reson Imaging. 2010, 31: 838-844. 10.1002/jmri.22061.CrossRefPubMed
19.
go back to reference Davarpanah AH, Chen YP, Kino A, Farrelly CT, Keeling AN, Sheehan JJ, Ragin AB, Weale PJ, Zuehlsdorff S, Carr JC: Accelerated two- and three-dimensional cine MR imaging of the heart by using a 32-channel coil. Radiology. 2010, 254: 98-108. 10.1148/radiol.2541090545.CrossRefPubMed Davarpanah AH, Chen YP, Kino A, Farrelly CT, Keeling AN, Sheehan JJ, Ragin AB, Weale PJ, Zuehlsdorff S, Carr JC: Accelerated two- and three-dimensional cine MR imaging of the heart by using a 32-channel coil. Radiology. 2010, 254: 98-108. 10.1148/radiol.2541090545.CrossRefPubMed
20.
go back to reference Kozerke S, Tsao J, Razavi R, Boesiger P: Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med. 2004, 52: 19-26. 10.1002/mrm.20145.CrossRefPubMed Kozerke S, Tsao J, Razavi R, Boesiger P: Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med. 2004, 52: 19-26. 10.1002/mrm.20145.CrossRefPubMed
21.
go back to reference Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE: 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging. 2004, 20: 411-416. 10.1002/jmri.20145.PubMedCentralCrossRefPubMed Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE: 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging. 2004, 20: 411-416. 10.1002/jmri.20145.PubMedCentralCrossRefPubMed
22.
go back to reference Jahnke C, Nagel E, Gebker R, Bornstedt A, Schnackenburg B, Kozerke S, Fleck E, Paetsch I: Four-dimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass. J Magn Reson Imaging. 2007, 25: 737-742. 10.1002/jmri.20877.CrossRefPubMed Jahnke C, Nagel E, Gebker R, Bornstedt A, Schnackenburg B, Kozerke S, Fleck E, Paetsch I: Four-dimensional single breathhold magnetic resonance imaging using kt-BLAST enables reliable assessment of left- and right-ventricular volumes and mass. J Magn Reson Imaging. 2007, 25: 737-742. 10.1002/jmri.20877.CrossRefPubMed
23.
go back to reference Greil GF, Boettger T, Germann S, Klumpp B, Baltes C, Kozerke S, Bialkowski A, Urschitz MS, Miller S, Wolf I, et al: Quantitative assessment of ventricular function using three-dimensional SSFP magnetic resonance angiography. J Magn Reson Imaging. 2007, 26: 288-295. 10.1002/jmri.20967.CrossRefPubMed Greil GF, Boettger T, Germann S, Klumpp B, Baltes C, Kozerke S, Bialkowski A, Urschitz MS, Miller S, Wolf I, et al: Quantitative assessment of ventricular function using three-dimensional SSFP magnetic resonance angiography. J Magn Reson Imaging. 2007, 26: 288-295. 10.1002/jmri.20967.CrossRefPubMed
24.
go back to reference Shellock FG: Reference manual for magnetic resonance safety. 2003, Salt Lake City, Utah: Amirsys, 2003 Shellock FG: Reference manual for magnetic resonance safety. 2003, Salt Lake City, Utah: Amirsys, 2003
25.
go back to reference Bai W, Shi W, O’Regan DP, Tong T, Wang H, Jamil-Copley S, Peters NS, Rueckert D: A probabilistic patch-based label fusion model for multi-atlas segmentation with registration refinement: application to cardiac MR images. IEEE Trans Med Imaging. 2013, 32: 1302-1315.CrossRefPubMed Bai W, Shi W, O’Regan DP, Tong T, Wang H, Jamil-Copley S, Peters NS, Rueckert D: A probabilistic patch-based label fusion model for multi-atlas segmentation with registration refinement: application to cardiac MR images. IEEE Trans Med Imaging. 2013, 32: 1302-1315.CrossRefPubMed
26.
go back to reference Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G: User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. Neuroimage. 2006, 31: 1116-1128. 10.1016/j.neuroimage.2006.01.015.CrossRefPubMed Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G: User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. Neuroimage. 2006, 31: 1116-1128. 10.1016/j.neuroimage.2006.01.015.CrossRefPubMed
27.
go back to reference Shi W, Caballero J, Ledig C, Zhuang X, Bai W, Bhatia K, Marvao A, Dawes T, O’Regan D, Rueckert D: Cardiac Image Super-Resolution with Global Correspondence Using Multi-Atlas PatchMatch. Medical Image Computing and Computer-Assisted Intervention – MICCAI 2013.Volume 8151. Edited by: Mori K, Sakuma I, Sato Y, Barillot C, Navab N. 2013, Berlin Heidelberg: Springer, 9-16. Lecture Notes in Computer Science]CrossRef Shi W, Caballero J, Ledig C, Zhuang X, Bai W, Bhatia K, Marvao A, Dawes T, O’Regan D, Rueckert D: Cardiac Image Super-Resolution with Global Correspondence Using Multi-Atlas PatchMatch. Medical Image Computing and Computer-Assisted Intervention – MICCAI 2013.Volume 8151. Edited by: Mori K, Sakuma I, Sato Y, Barillot C, Navab N. 2013, Berlin Heidelberg: Springer, 9-16. Lecture Notes in Computer Science]CrossRef
28.
go back to reference Grevera GJ, Udupa JK: Shape-based interpolation of multidimensional grey-level images. IEEE Trans Med Imaging. 1996, 15: 881-892. 10.1109/42.544506.CrossRefPubMed Grevera GJ, Udupa JK: Shape-based interpolation of multidimensional grey-level images. IEEE Trans Med Imaging. 1996, 15: 881-892. 10.1109/42.544506.CrossRefPubMed
29.
go back to reference Lorensen WE, Cline HE: Marching cubes: A high resolution 3D surface construction algorithm. [Abstract]. Computer graphics. 1987, 21: 163-169. 10.1145/37402.37422.CrossRef Lorensen WE, Cline HE: Marching cubes: A high resolution 3D surface construction algorithm. [Abstract]. Computer graphics. 1987, 21: 163-169. 10.1145/37402.37422.CrossRef
30.
go back to reference Salton CJ, Chuang ML, O’Donnell CJ, Kupka MJ, Larson MG, Kissinger KV, Edelman RR, Levy D, Manning WJ: Gender differences and normal left ventricular anatomy in an adult population free of hypertension. A cardiovascular magnetic resonance study of the Framingham Heart Study Offspring cohort. J Am Coll Cardiol. 2002, 39: 1055-1060. 10.1016/S0735-1097(02)01712-6.CrossRefPubMed Salton CJ, Chuang ML, O’Donnell CJ, Kupka MJ, Larson MG, Kissinger KV, Edelman RR, Levy D, Manning WJ: Gender differences and normal left ventricular anatomy in an adult population free of hypertension. A cardiovascular magnetic resonance study of the Framingham Heart Study Offspring cohort. J Am Coll Cardiol. 2002, 39: 1055-1060. 10.1016/S0735-1097(02)01712-6.CrossRefPubMed
31.
go back to reference Dice LR: Measures of the Amount of Ecologic Association Between Species. Ecology. 1945, 26: 297-302. 10.2307/1932409.CrossRef Dice LR: Measures of the Amount of Ecologic Association Between Species. Ecology. 1945, 26: 297-302. 10.2307/1932409.CrossRef
32.
go back to reference Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU: Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging. 2003, 17: 323-329. 10.1002/jmri.10262.CrossRefPubMed Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU: Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging. 2003, 17: 323-329. 10.1002/jmri.10262.CrossRefPubMed
33.
go back to reference Malamateniou C, McGuinness AK, Allsop JM, O’Regan DP, Rutherford MA, Hajnal JV: Snapshot Inversion Recovery: An Optimized Single-Shot T1-weighted Inversion-Recovery Sequence for Improved Fetal Brain Anatomic Delineation. Radiology. 2011, 258: 229-235. 10.1148/radiol.10100381.CrossRefPubMed Malamateniou C, McGuinness AK, Allsop JM, O’Regan DP, Rutherford MA, Hajnal JV: Snapshot Inversion Recovery: An Optimized Single-Shot T1-weighted Inversion-Recovery Sequence for Improved Fetal Brain Anatomic Delineation. Radiology. 2011, 258: 229-235. 10.1148/radiol.10100381.CrossRefPubMed
35.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1: 307-310.CrossRefPubMed Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986, 1: 307-310.CrossRefPubMed
37.
go back to reference Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol. 2002, 90: 29-34. 10.1016/S0002-9149(02)02381-0.CrossRefPubMed Grothues F, Smith GC, Moon JC, Bellenger NG, Collins P, Klein HU, Pennell DJ: Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy. Am J Cardiol. 2002, 90: 29-34. 10.1016/S0002-9149(02)02381-0.CrossRefPubMed
38.
go back to reference Rodriguez CJ, Diez-Roux AV, Moran A, Jin Z, Kronmal RA, Lima J, Homma S, Bluemke DA, Barr RG: Left ventricular mass and ventricular remodeling among Hispanic subgroups compared with non-Hispanic blacks and whites: MESA (Multi-ethnic Study of Atherosclerosis). J Am Coll Cardiol. 2010, 55: 234-242. 10.1016/j.jacc.2009.08.046.PubMedCentralCrossRefPubMed Rodriguez CJ, Diez-Roux AV, Moran A, Jin Z, Kronmal RA, Lima J, Homma S, Bluemke DA, Barr RG: Left ventricular mass and ventricular remodeling among Hispanic subgroups compared with non-Hispanic blacks and whites: MESA (Multi-ethnic Study of Atherosclerosis). J Am Coll Cardiol. 2010, 55: 234-242. 10.1016/j.jacc.2009.08.046.PubMedCentralCrossRefPubMed
39.
go back to reference Gupta S, Berry JD, Ayers CR, Peshock RM, Khera A, de Lemos JA, Patel PC, Markham DW, Drazner MH: Left ventricular hypertrophy, aortic wall thickness, and lifetime predicted risk of cardiovascular disease:the Dallas Heart Study. JACC Cardiovascular imaging. 2010, 3: 605-613. 10.1016/j.jcmg.2010.03.005.CrossRefPubMed Gupta S, Berry JD, Ayers CR, Peshock RM, Khera A, de Lemos JA, Patel PC, Markham DW, Drazner MH: Left ventricular hypertrophy, aortic wall thickness, and lifetime predicted risk of cardiovascular disease:the Dallas Heart Study. JACC Cardiovascular imaging. 2010, 3: 605-613. 10.1016/j.jcmg.2010.03.005.CrossRefPubMed
40.
go back to reference Fox ER, Musani SK, Barbalic M, Lin H, Yu B, Ogunyankin KO, Smith NL, Kutlar A, Glazer NL, Post WS, et al: Genome-wide association study of cardiac structure and systolic function in African Americans: the Candidate Gene Association Resource (CARe) study. Circulation Cardiovascular genetics. 2013, 6: 37-46.PubMedCentralCrossRefPubMed Fox ER, Musani SK, Barbalic M, Lin H, Yu B, Ogunyankin KO, Smith NL, Kutlar A, Glazer NL, Post WS, et al: Genome-wide association study of cardiac structure and systolic function in African Americans: the Candidate Gene Association Resource (CARe) study. Circulation Cardiovascular genetics. 2013, 6: 37-46.PubMedCentralCrossRefPubMed
41.
go back to reference Chun EJ, Choi SI, Jin KN, Kwag HJ, Kim YJ, Choi BW, Lee W, Park JH: Hypertrophic Cardiomyopathy: Assessment with MR Imaging and Multidetector CT1. Radiographics. 2010, 30: 1309-1328. 10.1148/rg.305095074.CrossRefPubMed Chun EJ, Choi SI, Jin KN, Kwag HJ, Kim YJ, Choi BW, Lee W, Park JH: Hypertrophic Cardiomyopathy: Assessment with MR Imaging and Multidetector CT1. Radiographics. 2010, 30: 1309-1328. 10.1148/rg.305095074.CrossRefPubMed
42.
go back to reference Ganau A, Devereux RB, Roman MJ, de Simone G, Pickering TG, Saba PS, Vargiu P, Simongini I, Laragh JH: Patterns of left ventricular hypertrophy and geometric remodeling in essential hypertension. J Am Coll Cardiol. 1992, 19: 1550-1558. 10.1016/0735-1097(92)90617-V.CrossRefPubMed Ganau A, Devereux RB, Roman MJ, de Simone G, Pickering TG, Saba PS, Vargiu P, Simongini I, Laragh JH: Patterns of left ventricular hypertrophy and geometric remodeling in essential hypertension. J Am Coll Cardiol. 1992, 19: 1550-1558. 10.1016/0735-1097(92)90617-V.CrossRefPubMed
43.
go back to reference Pattynama PM, Doornbos J, Hermans J, van der Wall EE, de Roos A: Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion. Investigative radiology. 1992, 27: 681-685. 10.1097/00004424-199209000-00004.CrossRefPubMed Pattynama PM, Doornbos J, Hermans J, van der Wall EE, de Roos A: Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion. Investigative radiology. 1992, 27: 681-685. 10.1097/00004424-199209000-00004.CrossRefPubMed
44.
go back to reference Bloomer TN, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU: Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson Imaging. 2001, 14: 685-692. 10.1002/jmri.10019.CrossRefPubMed Bloomer TN, Plein S, Radjenovic A, Higgins DM, Jones TR, Ridgway JP, Sivananthan MU: Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle. J Magn Reson Imaging. 2001, 14: 685-692. 10.1002/jmri.10019.CrossRefPubMed
45.
46.
go back to reference Makowski MR, Wiethoff AJ, Jansen CH, Uribe S, Parish V, Schuster A, Botnar RM, Bell A, Kiesewetter C, Razavi R, et al: Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique–comparison of an intravascular and extravascular contrast agent. J Cardiovasc Magn Reson. 2012, 14: 53-10.1186/1532-429X-14-53.PubMedCentralCrossRefPubMed Makowski MR, Wiethoff AJ, Jansen CH, Uribe S, Parish V, Schuster A, Botnar RM, Bell A, Kiesewetter C, Razavi R, et al: Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique–comparison of an intravascular and extravascular contrast agent. J Cardiovasc Magn Reson. 2012, 14: 53-10.1186/1532-429X-14-53.PubMedCentralCrossRefPubMed
48.
go back to reference Petersen SE, Matthews PM, Bamberg F, Bluemke DA, Francis JM, Friedrich MG, Leeson P, Nagel E, Plein S, Rademakers FE, et al: Imaging in population science: cardiovascular magnetic resonance in 100,000 participants of UK Biobank - rationale, challenges and approaches. J Cardiovasc Magn Reson. 2013, 15: 46-10.1186/1532-429X-15-46.PubMedCentralCrossRefPubMed Petersen SE, Matthews PM, Bamberg F, Bluemke DA, Francis JM, Friedrich MG, Leeson P, Nagel E, Plein S, Rademakers FE, et al: Imaging in population science: cardiovascular magnetic resonance in 100,000 participants of UK Biobank - rationale, challenges and approaches. J Cardiovasc Magn Reson. 2013, 15: 46-10.1186/1532-429X-15-46.PubMedCentralCrossRefPubMed
49.
go back to reference Mirnezami R, Nicholson J, Darzi A: Preparing for precision medicine. N Engl J Med. 2012, 366: 489-491. 10.1056/NEJMp1114866.CrossRefPubMed Mirnezami R, Nicholson J, Darzi A: Preparing for precision medicine. N Engl J Med. 2012, 366: 489-491. 10.1056/NEJMp1114866.CrossRefPubMed
50.
go back to reference Bland M: An introduction to medical statistics. 2000, Oxford; New York: Oxford University Press, 3 Bland M: An introduction to medical statistics. 2000, Oxford; New York: Oxford University Press, 3
Metadata
Title
Population-based studies of myocardial hypertrophy: high resolution cardiovascular magnetic resonance atlases improve statistical power
Authors
Antonio de Marvao
Timothy JW Dawes
Wenzhe Shi
Christopher Minas
Niall G Keenan
Tamara Diamond
Giuliana Durighel
Giovanni Montana
Daniel Rueckert
Stuart A Cook
Declan P O’Regan
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2014
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-16-16

Other articles of this Issue 1/2014

Journal of Cardiovascular Magnetic Resonance 1/2014 Go to the issue