Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method

Authors: Michael P. Margarson, Neil C. Soni

Published in: Intensive Care Medicine | Issue 2/2005

Login to get access

Abstract

Objective

To investigate a technique using 20% albumin for measurement of plasma volume in critically ill patients.

Design and setting

Laboratory and clinical investigation in the adult intensive care unit and anaesthetic laboratories of a university hospital.

Patients

12 patients fulfilling ACCP/SCCM criteria for septic shock.

Interventions and measurements

Each patient received 125I-labelled albumin, and the volume of distribution was measured at 1 and 10 min. The accepted standard plasma volume measurement (98% of the 10-min volume of distribution) was calculated. Immediately thereafter 200 ml 20% human albumin was given. Albumin concentrations were measured before and 1 min after this 40-g bolus, and the volume of distribution calculated using a formula that corrected for the 200 ml fluid in which the albumin was dissolved.

Results

Plasma volumes measured using the albumin dilution technique at 1 min were smaller than the standard technique by 110±280 ml; limits of agreement were from −660 to +440 ml (−16% to +11%). Plasma volumes measured by 125I-albumin at 1 min were smaller than the standard by 120±110 ml; limits of agreement were from −330 to +100 ml (−8 to +2%).

Conclusions

Non-labelled albumin can be used easily and quickly to measure a plasma volume in ICU patients and gives a moderately accurate estimate when compared with the 125I-labelled albumin methods. The normal isotope method over-estimates plasma volumes in septic patients because excessive transcapillary escape of albumin is inadequately compensated for by the standard correction factor.
Appendix
Available only for authorised users
Literature
1.
go back to reference Bone RC, Balk RA, Cerra FB, Dellinger RP, Feim AM, Knaus WA, Schein RM, Sibbald WJ (1992) Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. The ACCP/SCCM Consensus Conference Committee. American College of Chest Physicians/Society of Critical Care Medicine. Chest 101:1644–1645PubMed Bone RC, Balk RA, Cerra FB, Dellinger RP, Feim AM, Knaus WA, Schein RM, Sibbald WJ (1992) Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. The ACCP/SCCM Consensus Conference Committee. American College of Chest Physicians/Society of Critical Care Medicine. Chest 101:1644–1645PubMed
2.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet I:307–310
3.
go back to reference Tchaikowsky K, Meisner M, Durst R, Rugheimer R (1997) Blood volume determination using hydroxyethyl starch: a rapid and simple intravenous injection method. Crit Care Med 25:599–606CrossRefPubMed Tchaikowsky K, Meisner M, Durst R, Rugheimer R (1997) Blood volume determination using hydroxyethyl starch: a rapid and simple intravenous injection method. Crit Care Med 25:599–606CrossRefPubMed
4.
go back to reference Van Kreel BK, van Beek E, Spaanderman ME, Peeters LL (1998) A new method for plasma volume measurements with unlabelled dextran-70 instead of 125-I-labelled albumin as an indicator. Clin Chim Acta 275:71–80CrossRefPubMed Van Kreel BK, van Beek E, Spaanderman ME, Peeters LL (1998) A new method for plasma volume measurements with unlabelled dextran-70 instead of 125-I-labelled albumin as an indicator. Clin Chim Acta 275:71–80CrossRefPubMed
5.
go back to reference Brown MA, Mitar DA, Whitworth JA (1992) Measurement of plasma volume in pregnancy. Clin Sci (Colch) 83:29–34 Brown MA, Mitar DA, Whitworth JA (1992) Measurement of plasma volume in pregnancy. Clin Sci (Colch) 83:29–34
6.
go back to reference Anthony MY, Goodall SR, Papouli M, Levene MI (1992) Measurement of plasma volume in neonates. Arch Dis Child 67:36–40PubMed Anthony MY, Goodall SR, Papouli M, Levene MI (1992) Measurement of plasma volume in neonates. Arch Dis Child 67:36–40PubMed
7.
go back to reference Gillen CM, Takamata A, Mack GW, Nadel ER (1994) Measurement of plasma volume in rats with use of fluorescent-labelled albumin molecules. J Appl Physiol 76:485–489PubMed Gillen CM, Takamata A, Mack GW, Nadel ER (1994) Measurement of plasma volume in rats with use of fluorescent-labelled albumin molecules. J Appl Physiol 76:485–489PubMed
8.
go back to reference Haruna M, Kumon K, Yahagi N, Watanabe Y, Ishida Y, Kobayashi N, Aoyagi T (1998) Blood volume measurement at the bedside using ICG pulse spectrophotometry. Anesthesiology 89:1310–1312CrossRefPubMed Haruna M, Kumon K, Yahagi N, Watanabe Y, Ishida Y, Kobayashi N, Aoyagi T (1998) Blood volume measurement at the bedside using ICG pulse spectrophotometry. Anesthesiology 89:1310–1312CrossRefPubMed
9.
go back to reference Thomsen JK, Fogh-Andersen N, Bülow K, Devantier A (1991) Blood and plasma volumes determined by carbon monoxide gas,99mTc-labelled erythrocytes, 125I-albumin and the T 1824 technique. Scand J Clin Invest 51:185–189PubMed Thomsen JK, Fogh-Andersen N, Bülow K, Devantier A (1991) Blood and plasma volumes determined by carbon monoxide gas,99mTc-labelled erythrocytes, 125I-albumin and the T 1824 technique. Scand J Clin Invest 51:185–189PubMed
10.
go back to reference Farjanel J, Denis C, Chatard JC, Geyssant A (1997) An accurate method of plasma volume measurement by direct analysis of Evans blue spectra in plasma without dye extraction: origins of albumin-space variations during maximal exercise. Eur J Appl Physiol 75:75–82CrossRef Farjanel J, Denis C, Chatard JC, Geyssant A (1997) An accurate method of plasma volume measurement by direct analysis of Evans blue spectra in plasma without dye extraction: origins of albumin-space variations during maximal exercise. Eur J Appl Physiol 75:75–82CrossRef
11.
go back to reference Cochrane Injuries Group (1998) Human albumin administration in critically ill patients: systematic review of randomised controlled trials. BMJ 317:235–240PubMed Cochrane Injuries Group (1998) Human albumin administration in critically ill patients: systematic review of randomised controlled trials. BMJ 317:235–240PubMed
12.
go back to reference Bunn F, Alderson P, Hawkins V (2000) Colloid fluids for fluid resuscitation. Cochrane database systematic review reference 2. pages CD001319 Bunn F, Alderson P, Hawkins V (2000) Colloid fluids for fluid resuscitation. Cochrane database systematic review reference 2. pages CD001319
Metadata
Title
Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method
Authors
Michael P. Margarson
Neil C. Soni
Publication date
01-02-2005
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 2/2005
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-004-2481-4

Other articles of this Issue 2/2005

Intensive Care Medicine 2/2005 Go to the issue