Skip to main content
Top
Published in: Journal of Cardiothoracic Surgery 1/2021

Open Access 01-12-2021 | Phenprocoumon | Research article

Risk of venous occlusion after lead laser extraction preventing future lead implantation

Authors: Sameer Al-Maisary, Jamila Kremer, Gabrielle Romano, Matthias Karck, Raffaele De Simone

Published in: Journal of Cardiothoracic Surgery | Issue 1/2021

Login to get access

Abstract

Background

Lead laser extraction is a well-established method for removing unwanted leads with low morbidity and mortality.

Objective

In this observational study, we documented our experience with venous occlusion after lead laser extraction.

Methods

Retrospective data of patients who underwent lead laser extraction between May 2010 and August 2018 was analyzed. Two subgroups of patients were identified. First group represented patients after lead laser extraction who suffered postoperative venous occlusion. Second group represents patients after lead laser extraction, who has documented patent venous access after lead laser extraction.

Results

219 patients underwent percutaneous laser lead extraction. The mean age of patients was 65 ± 14 years. Of these patients, 74% were male. The Most common indication for extraction was Nonfunctional lead (45.2%, n = 99) followed by pocket infection with 33.8% and endocarditis (17.3%). A total number of 447 leads underwent laser extraction. In 7.8% of the patients, lead extraction was partially successful and lead extraction was not successful in only 2.3% of the patients. Only 13 patients developed a documented venous occlusion postoperatively and 26 patients has documented absence of venous occlusion, of whom 17 were under oral anticoagulation.

Conclusion

Lead laser extraction may lead to venous occlusion, which is mostly asymptomatic but it prevents future lead implantation. The use of oral anticoagulant may prevent postoperative venous occlusion.
Literature
1.
go back to reference Klug D, Lacroix D, Savoye C, et al. Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management. Circulation. 1997;95:2098–107.CrossRef Klug D, Lacroix D, Savoye C, et al. Systemic infection related to endocarditis on pacemaker leads: clinical presentation and management. Circulation. 1997;95:2098–107.CrossRef
2.
go back to reference Goldberger Z, Lampert R. Implantable cardioverter-defibrillators: expanding indications and technologies. JAMA. 2006;295:809–18.CrossRef Goldberger Z, Lampert R. Implantable cardioverter-defibrillators: expanding indications and technologies. JAMA. 2006;295:809–18.CrossRef
3.
go back to reference Love CJ, Wilkoff BL, Byrd CL, et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and electrophysiology lead extraction conference faculty. Pacing Clin Electrophysiol. 2000;23:544–51.CrossRef Love CJ, Wilkoff BL, Byrd CL, et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and electrophysiology lead extraction conference faculty. Pacing Clin Electrophysiol. 2000;23:544–51.CrossRef
4.
go back to reference Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C. Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing Clin Electrophysiol. 2002;25:804–8.CrossRef Byrd CL, Wilkoff BL, Love CJ, Sellers TD, Reiser C. Clinical study of the laser sheath for lead extraction: the total experience in the United States. Pacing Clin Electrophysiol. 2002;25:804–8.CrossRef
5.
go back to reference Sohail MR, Uslan DZ, Khan AH, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverterdefibrillator infection. Mayo Clin Proc. 2008;83:46–53.CrossRef Sohail MR, Uslan DZ, Khan AH, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverterdefibrillator infection. Mayo Clin Proc. 2008;83:46–53.CrossRef
6.
go back to reference Sohail MR, Uslan DZ, Khan AH, et al. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol. 2007;49:1851–9.CrossRef Sohail MR, Uslan DZ, Khan AH, et al. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol. 2007;49:1851–9.CrossRef
7.
go back to reference Silvetti MS, Drago F. Outcome of young patients with abandoned, nonfunctional endocardial leads. Pacing Clin Electrophysiol. 2008;31:473–9.CrossRef Silvetti MS, Drago F. Outcome of young patients with abandoned, nonfunctional endocardial leads. Pacing Clin Electrophysiol. 2008;31:473–9.CrossRef
8.
go back to reference Vogt PR, Sagdic K, Lachat M, et al. Surgical management of infected permanenttransvenous pacemaker systems: ten year experience. J Card Surg. 1996;11:180–6.CrossRef Vogt PR, Sagdic K, Lachat M, et al. Surgical management of infected permanenttransvenous pacemaker systems: ten year experience. J Card Surg. 1996;11:180–6.CrossRef
9.
go back to reference Lai KK, Fontecchio SA. Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: epidemiology, infection control, and management. Clin Infect Dis. 1998;27:265–9.CrossRef Lai KK, Fontecchio SA. Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: epidemiology, infection control, and management. Clin Infect Dis. 1998;27:265–9.CrossRef
10.
go back to reference Tarakji KG, et al. Unrecognized venous injuries after cardiac implantable electronic device transvenous lead extraction. Heart Rhythm. 2018;15(3):318–25.CrossRef Tarakji KG, et al. Unrecognized venous injuries after cardiac implantable electronic device transvenous lead extraction. Heart Rhythm. 2018;15(3):318–25.CrossRef
11.
go back to reference Al-Maisary SSA. Epicardial pacemaker as a bridge for pacemaker-dependent patients undergoing explantation of infected cardiac implantable electronic devices. J Card Surg. 2019;34(6):424–7.CrossRef Al-Maisary SSA. Epicardial pacemaker as a bridge for pacemaker-dependent patients undergoing explantation of infected cardiac implantable electronic devices. J Card Surg. 2019;34(6):424–7.CrossRef
12.
go back to reference Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH III, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm. 2009;6:1085–104.CrossRef Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH III, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm. 2009;6:1085–104.CrossRef
13.
go back to reference Bongiorni MG, Kennergren C, Butter C, et al. The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) registry of transvenous lead extraction outcomes. Eur Heart J. 2017;38:2995–3005.CrossRef Bongiorni MG, Kennergren C, Butter C, et al. The European Lead Extraction ConTRolled (ELECTRa) study: a European Heart Rhythm Association (EHRA) registry of transvenous lead extraction outcomes. Eur Heart J. 2017;38:2995–3005.CrossRef
14.
go back to reference Wazni O, Epstein LM, Carrillo RG, Love C, Adler SW, Riggio DW, et al. Lead extraction in the contemporary setting: the LExICon study: an observational ret-rospective study of consecutive laser lead extractions. J Am Coll Cardiol. 2010;55–55:579–86.CrossRef Wazni O, Epstein LM, Carrillo RG, Love C, Adler SW, Riggio DW, et al. Lead extraction in the contemporary setting: the LExICon study: an observational ret-rospective study of consecutive laser lead extractions. J Am Coll Cardiol. 2010;55–55:579–86.CrossRef
15.
go back to reference Novak M, Dvorak P, Kamaryt P, Slana B, Lipoldova J. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes. Europace. 2009;11:1510–6.CrossRef Novak M, Dvorak P, Kamaryt P, Slana B, Lipoldova J. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes. Europace. 2009;11:1510–6.CrossRef
Metadata
Title
Risk of venous occlusion after lead laser extraction preventing future lead implantation
Authors
Sameer Al-Maisary
Jamila Kremer
Gabrielle Romano
Matthias Karck
Raffaele De Simone
Publication date
01-12-2021
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2021
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-021-01706-5

Other articles of this Issue 1/2021

Journal of Cardiothoracic Surgery 1/2021 Go to the issue