Published in: Pediatric Nephrology 5/2024

16-11-2023 | Peritoneal Dialysis | Original Article

Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis

Authors: Natthida Prukngampun, Narumon Densupsoontorn, Anirut Pattaragarn, Julaporn Pooliam, Intraparch Tinnabut, Achra Sumboonnanonda, Suroj Supavekin, Nuntawan Piyaphanee, Kraisoon Lomjansook, Yarnarin Thunsiribuddhichai, Thanaporn Chaiyapak

Published in: Pediatric Nephrology | Issue 5/2024

Login to get access

Abstract

Background

Previous adult studies have yielded conflicting results regarding whether the presence (D +) or absence (D-) of peritoneal dialysate affects the accuracy of bioelectrical impedance analysis (BIA) measurements. The aim of this study was to investigate whether the accuracy of BIA data varies between D + and D- measurements in children.

Methods

This cross-sectional study recruited chronic kidney disease stage 5 patients aged 3 to 18 years who received peritoneal dialysis. Body composition was assessed by multifrequency BIA, and values were compared between D + and D- measurements using the intraclass correlation coefficient (ICC).

Results

Fifty paired BIA measurements were collected from 18 patients with a mean age of 13.6 ± 4.1 years and a mean dialysate fill volume of 1,006 ± 239.7 ml/m2. Sixteen out of 17 BIA parameters (94.1%) exhibited excellent correlations between D + and D- measurements (ICC values = 0.954, 0.998). There was a trend of increased fluid status, including extracellular water, edema index, and overhydration, in D + measurements, with mean differences (95% CIs) of 0.5 (0.4, 0.6) L, 0.002 (0.001, 0.002), and 0.1 (0.1, 0.2) L, respectively. Soft lean mass and fat-free mass were higher in D + measurements, with mean differences (95% CIs) of 1.4 (1.2, 1.6), and 1.6 (1.4, 1.8) kg, respectively. In addition, patients older than 10 years had a stronger correlation between D + and D- measurements than younger patients.

Conclusions

A total of 94.1% of BIA parameters exhibited excellent correlations between D + and D- measurements, especially patients older than 10 years. We recommend that BIA measurements be collected from children regardless of the presence of peritoneal dialysate.
Literature
10.
go back to reference Cheng CH, Chen MY, Lee YJ et al (2000) Assessment of nutritional status in continuous ambulatory peritoneal dialysis patients: a comparison of bioelectric impedance and conventional methods. Zhonghua Yi Xue Za Zhi (Taipei) 63:758–764PubMed Cheng CH, Chen MY, Lee YJ et al (2000) Assessment of nutritional status in continuous ambulatory peritoneal dialysis patients: a comparison of bioelectric impedance and conventional methods. Zhonghua Yi Xue Za Zhi (Taipei) 63:758–764PubMed
17.
go back to reference Inbody, Co, Ltd (2015) Inbody user’s manual. Inbody Co Ltd, Seoul, Korea Inbody, Co, Ltd (2015) Inbody user’s manual. Inbody Co Ltd, Seoul, Korea
22.
go back to reference Bureau of Nutrition, Department of Public Health Thailand, Ministry of Public Health (2021) National growth reference for children 5–19 years. Thamduayjai Co., Ltd, Bangkok Bureau of Nutrition, Department of Public Health Thailand, Ministry of Public Health (2021) National growth reference for children 5–19 years. Thamduayjai Co., Ltd, Bangkok
Metadata
Title
Effect of peritoneal dialysate on bioelectrical impedance analysis variability in pediatric patients receiving peritoneal dialysis
Authors
Natthida Prukngampun
Narumon Densupsoontorn
Anirut Pattaragarn
Julaporn Pooliam
Intraparch Tinnabut
Achra Sumboonnanonda
Suroj Supavekin
Nuntawan Piyaphanee
Kraisoon Lomjansook
Yarnarin Thunsiribuddhichai
Thanaporn Chaiyapak
Publication date
16-11-2023
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Nephrology / Issue 5/2024
Print ISSN: 0931-041X
Electronic ISSN: 1432-198X
DOI
https://doi.org/10.1007/s00467-023-06219-y

Other articles of this Issue 5/2024

Pediatric Nephrology 5/2024 Go to the issue