Skip to main content
Top
Published in: Surgical Endoscopy 2/2008

01-02-2008

Peritoneal and systemic pH during pneumoperitoneum with CO2 and helium in a pig model

Authors: Maria Bergström, Peter Falk, Per-Ola Park, Lena Holmdahl

Published in: Surgical Endoscopy | Issue 2/2008

Login to get access

Abstract

Background

Local peritoneal effects of laparoscopic gases might be important in peritoneal biology during and after laparoscopic surgery. The most commonly used gas, CO2, is known to be well tolerated, but also causes changes in acid-base balance. Helium is an alternative gas for laparoscopy. Although safe, it is not widely used. In this study a method for monitoring peritoneal pH during laparoscopy was evaluated and peritoneal pH during CO2 and helium pneumoperitoneum was studied as well as its systemic reflection in arterial pH.

Methods

For these experiments 20 pigs were used, with ten exposed to pneumoperitoneum with CO2, and ten to helium. Peritoneal and sub-peritoneal pH were continuously measured before and during gas insufflation, during a 30-minute period with a pneumoperitoneum and during a 30-minute recovery period. Arterial blood-gases were collected immediately before gas insufflation, at its completion, at 30 minutes of pneumoperitoneum and after the recovery period.

Results

Peritoneal pH before gas insufflation was in all animals 7.4. An immediate local drop in pH (6.6) occurred in the peritoneum with CO2 insufflation. During pneumoperitoneum pH declined further, stabilising at 6.4, but was restored after the recovery period (7.3). With helium, tissue pH increased slightly (7.5) during insufflation, followed by a continuous decrease during pneumoperitoneum and recovery, reaching 7.2. Systemic pH decreased significantly with CO2 insufflation, and increased slightly during helium insufflation. Systemic pH showed co-variation with intra-peritoneal pH at the the end of insufflation and after 30 minutes of pneumoperitoneum.

Conclusions

Insufflation of CO2 into the peritoneal cavity seemed to result in an immediate decrease in peritoneal pH, a response that might influence biological events. This peritoneal effect also seems to influence systemic acid-base balance, probably due to trans-peritoneal absorption.
Literature
1.
go back to reference Neuhaus SJ, Gupta A, Watson DI (2001) Helium and other alternative insufflation gases for laparoscopy. Surg Endosc 15:553–560CrossRefPubMed Neuhaus SJ, Gupta A, Watson DI (2001) Helium and other alternative insufflation gases for laparoscopy. Surg Endosc 15:553–560CrossRefPubMed
2.
go back to reference Jacobi CA, Junghans T, Peter F, Naundorf D, Ordemann J, Muller JM (2000) Cardiopulmonary changes during laparoscopy and vessel injury: comparison of CO2 and helium in an animal model. Langenbeck Arch Surg 385:459–466CrossRef Jacobi CA, Junghans T, Peter F, Naundorf D, Ordemann J, Muller JM (2000) Cardiopulmonary changes during laparoscopy and vessel injury: comparison of CO2 and helium in an animal model. Langenbeck Arch Surg 385:459–466CrossRef
3.
go back to reference Lindahl TL, Sigurdardottir O, Wiman B (1989) Stability of plasminogen activator inhibitor 1 (PAI-1). Thromb Haemost 62:748–751PubMed Lindahl TL, Sigurdardottir O, Wiman B (1989) Stability of plasminogen activator inhibitor 1 (PAI-1). Thromb Haemost 62:748–751PubMed
4.
go back to reference Ranby M, Sundell IB, Nilsson TK (1989) Blood collection in strong acidic citrate anticoagulant used in a study of dietary influence on basal tPA activity. Thromb Haemost 62:917–922PubMed Ranby M, Sundell IB, Nilsson TK (1989) Blood collection in strong acidic citrate anticoagulant used in a study of dietary influence on basal tPA activity. Thromb Haemost 62:917–922PubMed
5.
go back to reference Kuntz C, Wunsch A, Bodeker C, Bay F, Rosch R, Windeler J, Herfarth C (2000) Effect of pressure and gas type on intraabdominal, subcutaneous, and blood pH in laparoscopy. Surg Endosc 14:367–371CrossRefPubMed Kuntz C, Wunsch A, Bodeker C, Bay F, Rosch R, Windeler J, Herfarth C (2000) Effect of pressure and gas type on intraabdominal, subcutaneous, and blood pH in laparoscopy. Surg Endosc 14:367–371CrossRefPubMed
6.
go back to reference Neuhaus SJ, Watson DI, Ellis T, Lafullarde T, Jamieson GG, Russell WJ (2001) Metabolic and immunologic consequences of laparoscopy with helium or carbon dioxide insufflation: a randomized clinical study. ANZ J Surg 71:447–452CrossRefPubMed Neuhaus SJ, Watson DI, Ellis T, Lafullarde T, Jamieson GG, Russell WJ (2001) Metabolic and immunologic consequences of laparoscopy with helium or carbon dioxide insufflation: a randomized clinical study. ANZ J Surg 71:447–452CrossRefPubMed
7.
go back to reference Bergstrom M, Ivarsson ML, Holmdahl L (2002) Peritoneal response to pneumoperitoneum and laparoscopic surgery. Brit J Surg 89:1465–1469CrossRefPubMed Bergstrom M, Ivarsson ML, Holmdahl L (2002) Peritoneal response to pneumoperitoneum and laparoscopic surgery. Brit J Surg 89:1465–1469CrossRefPubMed
8.
go back to reference Wong YT, Shah PC, Birkett DH, Brams DM (2004) Peritoneal pH during laparoscopy is dependent on ambient gas environment: helium and nitrous oxide do not cause peritoneal acidosis. Surg Endosc 19:60–64CrossRefPubMed Wong YT, Shah PC, Birkett DH, Brams DM (2004) Peritoneal pH during laparoscopy is dependent on ambient gas environment: helium and nitrous oxide do not cause peritoneal acidosis. Surg Endosc 19:60–64CrossRefPubMed
9.
go back to reference Rippe B, Rosengren BI, Venturoli D (2001) The peritoneal microcirculation in peritoneal dialysis. Microcirculation 8:303–320PubMed Rippe B, Rosengren BI, Venturoli D (2001) The peritoneal microcirculation in peritoneal dialysis. Microcirculation 8:303–320PubMed
10.
go back to reference Ho HS, Gunther RA, Wolfe BM (1992) Intraperitoneal carbon dioxide insufflation and cardiopulmonary functions. Laparoscopic cholecystectomy in pigs. Arch Surg 127:928–932PubMed Ho HS, Gunther RA, Wolfe BM (1992) Intraperitoneal carbon dioxide insufflation and cardiopulmonary functions. Laparoscopic cholecystectomy in pigs. Arch Surg 127:928–932PubMed
11.
go back to reference Lister DR, Rudston-Brown B, Warriner CB, McEwen J, Chan M Walley KR (1994) Carbon dioxide absorption is not linearly related to intraperitoneal carbon dioxide insufflation pressure in pigs. Anesthesiology 80:129–136CrossRefPubMed Lister DR, Rudston-Brown B, Warriner CB, McEwen J, Chan M Walley KR (1994) Carbon dioxide absorption is not linearly related to intraperitoneal carbon dioxide insufflation pressure in pigs. Anesthesiology 80:129–136CrossRefPubMed
12.
go back to reference Bergstrom M, Falk P, Holmdahl L (2003) CO2 promotes plasminogen activator inhibitor type 1 expression in human mesothelial cells. Surg Endosc 17:1818–1822CrossRefPubMed Bergstrom M, Falk P, Holmdahl L (2003) CO2 promotes plasminogen activator inhibitor type 1 expression in human mesothelial cells. Surg Endosc 17:1818–1822CrossRefPubMed
Metadata
Title
Peritoneal and systemic pH during pneumoperitoneum with CO2 and helium in a pig model
Authors
Maria Bergström
Peter Falk
Per-Ola Park
Lena Holmdahl
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 2/2008
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-007-9409-3

Other articles of this Issue 2/2008

Surgical Endoscopy 2/2008 Go to the issue