Skip to main content
Top
Published in: Surgical Endoscopy 10/2007

01-10-2007

Performance differences in laparoscopic surgical skills between true high-definition and three-chip CCD video systems

Authors: M. Hagiike, E. H. Phillips, G. Berci

Published in: Surgical Endoscopy | Issue 10/2007

Login to get access

Abstract

Background

Laparoscopic surgery requires surgeons to rely on visual clues for discrimination among differing tissues and for depth of field on a two-dimensional screen. High definition (HD) provides a superior image. If there is a measurable advantage with HD television (TV), the increase in the cost of the technology would be justified.

Methods

A digital three-chip CCD camera with a standard monitor (SD system) and a true HD camera (1,080 pixels) with a 16:9-ratio HD monitor (HD system) were compared in clinical and laboratory settings. Three experiments were performed: (1) subjective visual evaluation of the HD and SD systems during actual surgical cases, (2) subjective visual evaluation in a controlled laboratory surgical setting with simultaneous parallel recording, and (3) three laparoscopic surgical task evaluations in a laboratory setting, namely, task A (metric analysis of participants on the surgical simulator), task B (simple eye–hand coordination performance), and task C (knot tying).

Results

All 53 participants subjectively evaluated HD as superior to SD in the laboratory setting and during actual surgery. In task B, there was no significant difference between SD and HD (dominant hand: p = 0.19; nondominant hand: p = 0.07). In task C, the knot-tying time was significantly less when performed with HD (mean, 173 ± 84 s vs 214 ± 107 s; p = 0.003). Most importantly, subjects with less skill (more documented time required in the basic module on a surgical simulator) improved significantly in the knot-tying task with the HD system (R = 0.631; p = 0.005).

Conclusion

All the participants preferred HD to SD. High definition significantly improved laparoscopic knot tying, which requires precise depth perception, proving that HD is more than just a pretty picture.
Literature
1.
go back to reference Bhayani SB, Andriole GL (2005) Three-Dimensional (3D) Vision: Does It Improve Laparoscopic Skills? An Assessment of a 3D Head-Mounted Visualization System. Rev Urol 7(4):211–214PubMed Bhayani SB, Andriole GL (2005) Three-Dimensional (3D) Vision: Does It Improve Laparoscopic Skills? An Assessment of a 3D Head-Mounted Visualization System. Rev Urol 7(4):211–214PubMed
2.
go back to reference Szold A (2005) Seeing is believing: visualization systems in endoscopic surgery (video, HDTV,stereoscopy, and beyond). Surg Endosc 19:730–733PubMedCrossRef Szold A (2005) Seeing is believing: visualization systems in endoscopic surgery (video, HDTV,stereoscopy, and beyond). Surg Endosc 19:730–733PubMedCrossRef
3.
go back to reference Falk V, Mintz D, Grunenfelder J, Fann JI, Burdon TA (2001) Influence of three-dimensional vision on surgical telemanipulator performance. Surg Endosc 15:1282–1288PubMedCrossRef Falk V, Mintz D, Grunenfelder J, Fann JI, Burdon TA (2001) Influence of three-dimensional vision on surgical telemanipulator performance. Surg Endosc 15:1282–1288PubMedCrossRef
4.
go back to reference Otto KJ, Hapner ER, Baker M, Johns MM III (2006) Blinded evaluation of the effects of high definition and magnification on perceived image quality in laryngeal imaging. Ann Otol Rhinol Laryngol 115:110–113PubMed Otto KJ, Hapner ER, Baker M, Johns MM III (2006) Blinded evaluation of the effects of high definition and magnification on perceived image quality in laryngeal imaging. Ann Otol Rhinol Laryngol 115:110–113PubMed
5.
go back to reference van Bergen P, Kunert W, Buess GF (2000) The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope. Surg Endosc 14:71–74PubMedCrossRef van Bergen P, Kunert W, Buess GF (2000) The effect of high-definition imaging on surgical task efficiency in minimally invasive surgery: an experimental comparison between three-dimensional imaging and direct vision through a stereoscopic TEM rectoscope. Surg Endosc 14:71–74PubMedCrossRef
6.
go back to reference Berci G, Wren SM, Stain SC, Peters J, Paz-Partlow M (1995) Individual assessment of visual perception by surgeons observing the same laparoscopic organs with various imaging systems. Surg Endosc 9:967–973PubMed Berci G, Wren SM, Stain SC, Peters J, Paz-Partlow M (1995) Individual assessment of visual perception by surgeons observing the same laparoscopic organs with various imaging systems. Surg Endosc 9:967–973PubMed
7.
go back to reference Hiatt JR, Shabot MM, Phillips EH, Haines RF, Grant TL (1996) Telesurgery: acceptability of compressed video for remote surgical proctoring. Arch Surg 131:396–401PubMed Hiatt JR, Shabot MM, Phillips EH, Haines RF, Grant TL (1996) Telesurgery: acceptability of compressed video for remote surgical proctoring. Arch Surg 131:396–401PubMed
8.
go back to reference Yamaguchi S, Konishi K, Yasunaga T, Yoshida D, Kinjo N, Kobayashi K, Ieiri S, Okazaki K, Nakashima H, Tanoue K, Maehara Y, Hashizume M (2007) Construct validity for eye–hand coordination skill on a virtual reality laparoscopic surgical simulator. Surg Endosc DOI: 10.1007/s00464-007-9362-1, May 4, 2007 (Epub) Yamaguchi S, Konishi K, Yasunaga T, Yoshida D, Kinjo N, Kobayashi K, Ieiri S, Okazaki K, Nakashima H, Tanoue K, Maehara Y, Hashizume M (2007) Construct validity for eye–hand coordination skill on a virtual reality laparoscopic surgical simulator. Surg Endosc DOI: 10.1007/s00464-007-9362-1, May 4, 2007 (Epub)
9.
go back to reference Song CG, Park SK (2005) Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD. J Med Eng Technol 29:244–250PubMedCrossRef Song CG, Park SK (2005) Performance evaluation of stereo endoscopic imaging system incorporating TFT-LCD. J Med Eng Technol 29:244–250PubMedCrossRef
Metadata
Title
Performance differences in laparoscopic surgical skills between true high-definition and three-chip CCD video systems
Authors
M. Hagiike
E. H. Phillips
G. Berci
Publication date
01-10-2007
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 10/2007
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-007-9541-0

Other articles of this Issue 10/2007

Surgical Endoscopy 10/2007 Go to the issue