Abstract

We report the case of a percutaneous consolidation of a broken vertebral implant (Surgical Titanium Mesh Implants; DePuy Spine, Raynham, MA, USA) by vertebroplasty. Four years after anterior spondylectomy with cage implantation and stabilization with posterior instrumentation, the patient was admitted for excruciating back pain. Radiographs showed fracture of the cage, screw, and rod. An anterior surgical approach was deemed difficult and a percutaneous injection of polymethyl methacrylate into the cage was performed following posterior instrumentation replacement. This seems to be an interesting alternative to the classical anterior surgical approach, which is often difficult in postoperative conditions.
Literature
1.
go back to reference Fidler MW (1986) Anterior decompression and stabilisation of metastatic spinal fractures. J Bone Joint Surg Br 68(1):83PubMed Fidler MW (1986) Anterior decompression and stabilisation of metastatic spinal fractures. J Bone Joint Surg Br 68(1):83PubMed
2.
go back to reference Siegal T, Tiqva P, Siegal T (1985) Vertebral body resection for epidural compression by malignant tumors. Results of forty-seven consecutive operative procedures. J Bone Joint Surg Am 67(3):375PubMed Siegal T, Tiqva P, Siegal T (1985) Vertebral body resection for epidural compression by malignant tumors. Results of forty-seven consecutive operative procedures. J Bone Joint Surg Am 67(3):375PubMed
3.
go back to reference Bhat AL, Lowery GL, Sei A (1999) The use of titanium surgical mesh-bone graft composite in the anterior thoracic or lumbar spine after complete or partial corpectomy. Eur Spine J 8(4):304PubMedCrossRef Bhat AL, Lowery GL, Sei A (1999) The use of titanium surgical mesh-bone graft composite in the anterior thoracic or lumbar spine after complete or partial corpectomy. Eur Spine J 8(4):304PubMedCrossRef
4.
go back to reference Dvorak MF, Kwon BK, Fisher CG, et al. (2003) Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection. Spine 28(9):902PubMedCrossRef Dvorak MF, Kwon BK, Fisher CG, et al. (2003) Effectiveness of titanium mesh cylindrical cages in anterior column reconstruction after thoracic and lumbar vertebral body resection. Spine 28(9):902PubMedCrossRef
5.
go back to reference Shannon FJ, DiResta GR, Ottaviano D, et al. (2004) Biomechanical analysis of anterior poly-methyl-methacrylate reconstruction following total spondylectomy for metastatic disease. Spine 29(19):2096PubMedCrossRef Shannon FJ, DiResta GR, Ottaviano D, et al. (2004) Biomechanical analysis of anterior poly-methyl-methacrylate reconstruction following total spondylectomy for metastatic disease. Spine 29(19):2096PubMedCrossRef
6.
go back to reference Robertson PA, Rawlinson HJ, Hadlow AT (2004) Radiologic stability of titanium mesh cages for anterior spinal reconstruction following thoracolumbar corpectomy. J Spinal Disord Tech 17(1):44PubMedCrossRef Robertson PA, Rawlinson HJ, Hadlow AT (2004) Radiologic stability of titanium mesh cages for anterior spinal reconstruction following thoracolumbar corpectomy. J Spinal Disord Tech 17(1):44PubMedCrossRef
7.
go back to reference Hollowell JP, Vollmer DG, Wilson CR, et al. (1996) Biomechanical analysis of thoracolumbar interbody constructs. How important is the endplate? Spine 21(9):1032PubMedCrossRef Hollowell JP, Vollmer DG, Wilson CR, et al. (1996) Biomechanical analysis of thoracolumbar interbody constructs. How important is the endplate? Spine 21(9):1032PubMedCrossRef
8.
go back to reference Klemme WR, Cunningham BW, Polly LD, Jr (2002) Microradiographic and histopathologic findings in a human cage explant after two-level corpectomy: a case report. Spine 27(1):E15PubMedCrossRef Klemme WR, Cunningham BW, Polly LD, Jr (2002) Microradiographic and histopathologic findings in a human cage explant after two-level corpectomy: a case report. Spine 27(1):E15PubMedCrossRef
9.
go back to reference Kelekis AD, Martin JB, Somon T, et al. (2003) Radicular pain after vertebroplasty: compression or irritation of the nerve root? Initial experience with the “cooling system.” Spine 28(14):E265PubMedCrossRef Kelekis AD, Martin JB, Somon T, et al. (2003) Radicular pain after vertebroplasty: compression or irritation of the nerve root? Initial experience with the “cooling system.” Spine 28(14):E265PubMedCrossRef
10.
go back to reference Murphy KJ, Deramond H (2000) Percutaneous vertebroplasty in benign and malignant disease. Neuroimag Clin North Am 10(3):535 Murphy KJ, Deramond H (2000) Percutaneous vertebroplasty in benign and malignant disease. Neuroimag Clin North Am 10(3):535
11.
go back to reference Gangi A, Guth S, Imbert JP, et al. (2003) Percutaneous vertebroplasty: indications, technique, and results. Radiographics 23(2):e10PubMed Gangi A, Guth S, Imbert JP, et al. (2003) Percutaneous vertebroplasty: indications, technique, and results. Radiographics 23(2):e10PubMed
12.
go back to reference Gangi A, Kastler BA, Dietemann JL (1994) Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. Am J Neuroradiol 15(1):83PubMed Gangi A, Kastler BA, Dietemann JL (1994) Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. Am J Neuroradiol 15(1):83PubMed
13.
go back to reference Verlaan JJ, Dhert WJ, Verbout AJ, et al. (2005) Balloon vertebroplasty in combination with pedicle screw instrumentation: A novel technique to treat thoracic and lumbar burst fractures. Spine 30(3):E73PubMedCrossRef Verlaan JJ, Dhert WJ, Verbout AJ, et al. (2005) Balloon vertebroplasty in combination with pedicle screw instrumentation: A novel technique to treat thoracic and lumbar burst fractures. Spine 30(3):E73PubMedCrossRef
14.
go back to reference Togawa D, Bauer TW, Lieberman IH, et al. (2003) Histology of tissues within retrieved human titanium mesh cages. Spine 28(3):246PubMedCrossRef Togawa D, Bauer TW, Lieberman IH, et al. (2003) Histology of tissues within retrieved human titanium mesh cages. Spine 28(3):246PubMedCrossRef
Metadata
Title
Percutaneous Vertebroplasty in a Broken Vertebral Titanium Implant (Titanium Mesh Cage)
Authors
G. Bierry
X. Buy
P. Chandra Mohan
J. Cupelli
J.P. Steib
A. Gangi
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
CardioVascular and Interventional Radiology / Issue 4/2006
Print ISSN: 0174-1551
Electronic ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-005-5278-0

Other articles of this Issue 4/2006

CardioVascular and Interventional Radiology 4/2006 Go to the issue