Skip to main content
Top
Published in: European Spine Journal 11/2010

01-11-2010 | Ideas and Technical Innovations

Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique

Authors: Shaunak Desai, Anil Sethi, Christopher C. Ninh, Stephen Bartol, Rahul Vaidya

Published in: European Spine Journal | Issue 11/2010

Login to get access

Abstract

Cervical pedicle screws have been reported to be biomechanically superior to lateral mass screws. However, placement of these implants is a technical challenge. The purpose of this investigation was to use an anatomic and a clinical study to evaluate a technique for placement of the pedicle screws in the C7 vertebra using fluoroscopic imaging in only the anteroposterior (A/P) plane. Ten adult cadaver C7 vertebrae were used to record the pedicle width, inclination and a suitable entry point for placement of pedicle screws. A prospective study of 28 patients undergoing posterior instrumentation of the cervical spine with C7 pedicle screw placement was also performed. A total of 55 C7 pedicle screws were placed using imaging only in the A/P plane with screw trajectory values obtained by the anatomic study. Radiographs and CT scans were performed post-operatively. The average posterior pedicle diameter of C7 vertebra was 9.5 ± 1.2 mm in this study. The average middle pedicle diameter was 7.1 mm and the average anterior pedicle diameter was 9.2 mm. The average transverse pedicle angle was 26.8 on the right and 27.3 on the left. CT scans were obtained on 20 of 28 patients which showed two asymptomatic cortical wall perforations. One screw penetrated the lateral wall of the pedicle and another displayed an anterior vertebral penetration. There were no medial wall perforations. The preliminary results suggest that this technique is safe and suitable for pedicle screw placement in the C7 vertebra.
Literature
1.
go back to reference An HS, Gordin R, Renner K (1991) Anatomic considerations for plate-screw fixation of the cervical spine. Spine 16:S548–S551CrossRefPubMed An HS, Gordin R, Renner K (1991) Anatomic considerations for plate-screw fixation of the cervical spine. Spine 16:S548–S551CrossRefPubMed
2.
go back to reference Barrey C, Cotton F, Jund J, Mertens P, Perrin G (2003) Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique. Surg Radiol Anat 25:354–360CrossRefPubMed Barrey C, Cotton F, Jund J, Mertens P, Perrin G (2003) Transpedicular screwing of the seventh cervical vertebra: anatomical considerations and surgical technique. Surg Radiol Anat 25:354–360CrossRefPubMed
3.
go back to reference Boyle J, Singer KP, Milne N (1996) Morphological survey of the cervicothoracic junctional region. Spine 21:544–548CrossRefPubMed Boyle J, Singer KP, Milne N (1996) Morphological survey of the cervicothoracic junctional region. Spine 21:544–548CrossRefPubMed
4.
go back to reference Jones LE, Heller J, Silcox HD, Hutton WC (1997) Cervical pedicle screw versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22(9):977–982CrossRefPubMed Jones LE, Heller J, Silcox HD, Hutton WC (1997) Cervical pedicle screw versus lateral mass screws: anatomic feasibility and biomechanical comparison. Spine 22(9):977–982CrossRefPubMed
5.
go back to reference Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13(1):63–72CrossRefPubMed Karaikovic EE, Kunakornsawat S, Daubs MD, Madsen TW, Gaines RW Jr (2000) Surgical anatomy of the cervical pedicles: landmarks for posterior cervical pedicle entrance localization. J Spinal Disord 13(1):63–72CrossRefPubMed
6.
go back to reference Lee GYF, Massicotte EM, Rampersaud YR (2007) A comparison of the “open” lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Tech 20:25–32CrossRefPubMed Lee GYF, Massicotte EM, Rampersaud YR (2007) A comparison of the “open” lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Tech 20:25–32CrossRefPubMed
7.
go back to reference Ludwig SC, Kowalski JM, Edwards CC, Heller JG (2000) Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine 25:2675–2681CrossRefPubMed Ludwig SC, Kowalski JM, Edwards CC, Heller JG (2000) Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine 25:2675–2681CrossRefPubMed
8.
go back to reference Ludwig SC, Kramer DL, Balderstone RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655–1667CrossRefPubMed Ludwig SC, Kramer DL, Balderstone RA, Vaccaro AR, Foley KF, Albert TJ (2000) Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655–1667CrossRefPubMed
9.
go back to reference Panjabi M, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebra: quantitative three-dimensional anatomy of the middle and lower regions. Spine 16:861–869CrossRefPubMed Panjabi M, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebra: quantitative three-dimensional anatomy of the middle and lower regions. Spine 16:861–869CrossRefPubMed
10.
go back to reference Reinhold M, Magerl F, Rieger M, Blauth M (2007) Cervical pedicle screw placement: feasibility and accuracy of two insertion techniques based on morphometric data. Eur Spine J 16:47–56CrossRefPubMed Reinhold M, Magerl F, Rieger M, Blauth M (2007) Cervical pedicle screw placement: feasibility and accuracy of two insertion techniques based on morphometric data. Eur Spine J 16:47–56CrossRefPubMed
11.
go back to reference Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT (1995) Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8:116–120PubMed Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT (1995) Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8:116–120PubMed
12.
go back to reference Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, Machino M (2009) Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 18(9):1293–1299 (Epub 2 Jun 2009)CrossRefPubMed Yukawa Y, Kato F, Ito K, Horie Y, Hida T, Nakashima H, Machino M (2009) Placement and complications of cervical pedicle screws in 144 cervical trauma patients using pedicle axis view techniques by fluoroscope. Eur Spine J 18(9):1293–1299 (Epub 2 Jun 2009)CrossRefPubMed
Metadata
Title
Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique
Authors
Shaunak Desai
Anil Sethi
Christopher C. Ninh
Stephen Bartol
Rahul Vaidya
Publication date
01-11-2010
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 11/2010
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-010-1513-8

Other articles of this Issue 11/2010

European Spine Journal 11/2010 Go to the issue