Skip to main content
Top
Published in: Critical Care 6/2013

Open Access 01-12-2013 | Viewpoint

Pavane for a pulse pressure variation defunct

Author: Soren Sondergaard

Published in: Critical Care | Issue 6/2013

Login to get access

Abstract

Hemodynamic management of critically ill patients in the ICU or high-risk patients in the operating room has paradoxically shown progress in terms of outcome after the systematic application of volume responsiveness/flow optimization based on pulse pressure variation and/or stroke volume variation during controlled, positive-pressure ventilation in patients without spontaneous respiratory efforts. This assessment of circulatory optimization should ideally be based on an exhaustive, predictive and coherent physiological understanding of the cardiovascular system model. This paper sketches the extremely complex physiological background of the concept of volume responsiveness, concluding that it is not a reliable means of guiding hemodynamic optimization because it is based on a nonexhaustive, nonpredictive and incoherent physiological model.
Appendix
Available only for authorised users
Literature
1.
go back to reference Perel A, Pizov R, Cotev S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987, 67: 498-502. 10.1097/00000542-198710000-00009CrossRefPubMed Perel A, Pizov R, Cotev S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987, 67: 498-502. 10.1097/00000542-198710000-00009CrossRefPubMed
2.
go back to reference Morgan BC, Martin WE, Hornbein TF, Crawford EW, Guntheroth WG: Hemodynamic effects of intermittent positive pressure respiration. Anesthesiology 1966, 27: 584-590. 10.1097/00000542-196609000-00009CrossRefPubMed Morgan BC, Martin WE, Hornbein TF, Crawford EW, Guntheroth WG: Hemodynamic effects of intermittent positive pressure respiration. Anesthesiology 1966, 27: 584-590. 10.1097/00000542-196609000-00009CrossRefPubMed
3.
go back to reference Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL: Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000, 162: 134-138. 10.1164/ajrccm.162.1.9903035CrossRefPubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL: Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000, 162: 134-138. 10.1164/ajrccm.162.1.9903035CrossRefPubMed
4.
go back to reference Michard F, Teboul JL: Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 2000, 4: 282-289. 10.1186/cc710PubMedCentralCrossRefPubMed Michard F, Teboul JL: Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 2000, 4: 282-289. 10.1186/cc710PubMedCentralCrossRefPubMed
5.
go back to reference Magder S: Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 2004, 169: 151-155. 10.1164/rccm.200211-1360CCCrossRefPubMed Magder S: Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 2004, 169: 151-155. 10.1164/rccm.200211-1360CCCrossRefPubMed
6.
go back to reference Michard F, Chemla D, Teboul JL: More respect for respiratory variation in arterial pressure. Am J Respir Crit Care Med 2004, 169: 1333-1334. author reply 1334 10.1164/ajrccm.169.12.954CrossRefPubMed Michard F, Chemla D, Teboul JL: More respect for respiratory variation in arterial pressure. Am J Respir Crit Care Med 2004, 169: 1333-1334. author reply 1334 10.1164/ajrccm.169.12.954CrossRefPubMed
7.
go back to reference Guyton AC: Determination of cardiac output by equating venous return curves with cardiac response curves. Physiol Rev 1955, 35: 123-129.PubMed Guyton AC: Determination of cardiac output by equating venous return curves with cardiac response curves. Physiol Rev 1955, 35: 123-129.PubMed
8.
go back to reference Magder S: Central venous pressure monitoring. Curr Opin Crit Care 2006, 12: 219-227. 10.1097/01.ccx.0000224866.01453.43CrossRefPubMed Magder S: Central venous pressure monitoring. Curr Opin Crit Care 2006, 12: 219-227. 10.1097/01.ccx.0000224866.01453.43CrossRefPubMed
9.
go back to reference Yang ZL, Zhou JQ, Sun BL, Qian ZX, Zhao H, Liu WD: The influence of positive end-expiratory pressure on central venous pressure in patients with severe craniocerebral injury. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue 2012, 24: 283-285.PubMed Yang ZL, Zhou JQ, Sun BL, Qian ZX, Zhao H, Liu WD: The influence of positive end-expiratory pressure on central venous pressure in patients with severe craniocerebral injury. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue 2012, 24: 283-285.PubMed
10.
go back to reference Chihara E, Hashimoto S, Kinoshita T, Hirose M, Tanaka Y, Morimoto T: Elevated mean systemic filling pressure due to intermittent positive-pressure ventilation. Am J Physiol 1992, 262: H1116-H1121.PubMed Chihara E, Hashimoto S, Kinoshita T, Hirose M, Tanaka Y, Morimoto T: Elevated mean systemic filling pressure due to intermittent positive-pressure ventilation. Am J Physiol 1992, 262: H1116-H1121.PubMed
12.
go back to reference Wyler von Ballmoos M, Takala J, Roeck M, Porta F, Tueller D, Ganter CC, Schroder R, Bracht H, Baenziger B, Jakob SM: Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study. Crit Care 2010, 14: R111. 10.1186/cc9060PubMedCentralCrossRefPubMed Wyler von Ballmoos M, Takala J, Roeck M, Porta F, Tueller D, Ganter CC, Schroder R, Bracht H, Baenziger B, Jakob SM: Pulse-pressure variation and hemodynamic response in patients with elevated pulmonary artery pressure: a clinical study. Crit Care 2010, 14: R111. 10.1186/cc9060PubMedCentralCrossRefPubMed
13.
go back to reference Daudel F, Tuller D, Krahenbuhl S, Jakob SM, Takala J: Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study. Crit Care 2010, 14: R122. 10.1186/cc9080PubMedCentralCrossRefPubMed Daudel F, Tuller D, Krahenbuhl S, Jakob SM, Takala J: Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study. Crit Care 2010, 14: R122. 10.1186/cc9080PubMedCentralCrossRefPubMed
14.
go back to reference Michard F, Richards G, Biais M, Lopes M, Auler JO: Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure? Crit Care 2010, 14: 451. author reply 451 10.1186/cc9303PubMedCentralCrossRefPubMed Michard F, Richards G, Biais M, Lopes M, Auler JO: Using pulse pressure variation or stroke volume variation to diagnose right ventricular failure? Crit Care 2010, 14: 451. author reply 451 10.1186/cc9303PubMedCentralCrossRefPubMed
15.
go back to reference Mahjoub Y, Pila C, Friggeri A, Zogheib E, Lobjoie E, Tinturier F, Galy C, Slama M, Dupont H: Assessing fluid responsiveness in critically ill patients: false-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle. Crit Care Med 2009, 37: 2570-2575. 10.1097/CCM.0b013e3181a380a3CrossRefPubMed Mahjoub Y, Pila C, Friggeri A, Zogheib E, Lobjoie E, Tinturier F, Galy C, Slama M, Dupont H: Assessing fluid responsiveness in critically ill patients: false-positive pulse pressure variation is detected by Doppler echocardiographic evaluation of the right ventricle. Crit Care Med 2009, 37: 2570-2575. 10.1097/CCM.0b013e3181a380a3CrossRefPubMed
16.
go back to reference Mesquida J, Kim HK, Pinsky MR: Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med 2011, 37: 1672-1679. 10.1007/s00134-011-2304-3CrossRefPubMed Mesquida J, Kim HK, Pinsky MR: Effect of tidal volume, intrathoracic pressure, and cardiac contractility on variations in pulse pressure, stroke volume, and intrathoracic blood volume. Intensive Care Med 2011, 37: 1672-1679. 10.1007/s00134-011-2304-3CrossRefPubMed
17.
go back to reference Michard F, Teboul JL: Évaluation des besoins volémiques en réanimation. Reanimation 2001, 10: 162-172. 10.1016/S1164-6756(01)00097-4CrossRef Michard F, Teboul JL: Évaluation des besoins volémiques en réanimation. Reanimation 2001, 10: 162-172. 10.1016/S1164-6756(01)00097-4CrossRef
19.
go back to reference Robotham JL, Cherry D, Mitzner W, Rabson JL, Lixfeld W, Bromberger-Barnea B: A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilation. Crit Care Med 1983, 11: 783-793. 10.1097/00003246-198310000-00005CrossRefPubMed Robotham JL, Cherry D, Mitzner W, Rabson JL, Lixfeld W, Bromberger-Barnea B: A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilation. Crit Care Med 1983, 11: 783-793. 10.1097/00003246-198310000-00005CrossRefPubMed
20.
go back to reference De Backer D, Taccone FS, Holsten R, Ibrahimi F, Vincent JL: Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology 2009, 110: 1092-1097. 10.1097/ALN.0b013e31819db2a1CrossRefPubMed De Backer D, Taccone FS, Holsten R, Ibrahimi F, Vincent JL: Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology 2009, 110: 1092-1097. 10.1097/ALN.0b013e31819db2a1CrossRefPubMed
21.
go back to reference de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF: Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009, 37: 510-515. 10.1097/CCM.0b013e3181958bf7CrossRefPubMed de Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF: Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009, 37: 510-515. 10.1097/CCM.0b013e3181958bf7CrossRefPubMed
22.
go back to reference Muller L, Louart G, Bousquet PJ, Candela D, Zoric L, de La Coussaye JE, Jaber S, Lefrant JY: The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med 2010, 36: 496-503. 10.1007/s00134-009-1686-yCrossRefPubMed Muller L, Louart G, Bousquet PJ, Candela D, Zoric L, de La Coussaye JE, Jaber S, Lefrant JY: The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness. Intensive Care Med 2010, 36: 496-503. 10.1007/s00134-009-1686-yCrossRefPubMed
23.
go back to reference De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL: Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005, 31: 517-523. 10.1007/s00134-005-2586-4CrossRefPubMed De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL: Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005, 31: 517-523. 10.1007/s00134-005-2586-4CrossRefPubMed
24.
go back to reference Schmitt JM, Vieillard-Baron A, Augarde R, Prin S, Page B, Jardin F: Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements. Crit Care Med 2001, 29: 1154-1158. 10.1097/00003246-200106000-00012CrossRefPubMed Schmitt JM, Vieillard-Baron A, Augarde R, Prin S, Page B, Jardin F: Positive end-expiratory pressure titration in acute respiratory distress syndrome patients: impact on right ventricular outflow impedance evaluated by pulmonary artery Doppler flow velocity measurements. Crit Care Med 2001, 29: 1154-1158. 10.1097/00003246-200106000-00012CrossRefPubMed
25.
go back to reference Magder S: Further cautions for the use of ventilatory-induced changes in arterial pressures to predict volume responsiveness. Crit Care 2010, 14: 197. 10.1186/cc9223PubMedCentralCrossRefPubMed Magder S: Further cautions for the use of ventilatory-induced changes in arterial pressures to predict volume responsiveness. Crit Care 2010, 14: 197. 10.1186/cc9223PubMedCentralCrossRefPubMed
26.
go back to reference Renner J, Gruenewald M, Quaden R, Hanss R, Meybohm P, Steinfath M, Scholz J, Bein B: Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med 2009, 37: 650-658. 10.1097/CCM.0b013e3181959864CrossRefPubMed Renner J, Gruenewald M, Quaden R, Hanss R, Meybohm P, Steinfath M, Scholz J, Bein B: Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med 2009, 37: 650-658. 10.1097/CCM.0b013e3181959864CrossRefPubMed
27.
go back to reference Freitas FG, Bafi AT, Nascente AP, Assuncao M, Mazza B, Azevedo LC, Machado FR: Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies. Br J Anaesth 2013, 110: 402-408. 10.1093/bja/aes398CrossRefPubMed Freitas FG, Bafi AT, Nascente AP, Assuncao M, Mazza B, Azevedo LC, Machado FR: Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies. Br J Anaesth 2013, 110: 402-408. 10.1093/bja/aes398CrossRefPubMed
28.
go back to reference Cavallaro F, Sandroni C, Antonelli M: Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol 2008, 74: 123-135.PubMed Cavallaro F, Sandroni C, Antonelli M: Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol 2008, 74: 123-135.PubMed
29.
go back to reference Smith F, Geyser M, Schreuder I, Becker P: The effect of positive end-expiratory pressure on pulse pressure variation. South Afr J Anaesth Analg 2012, 18: 333-338. Smith F, Geyser M, Schreuder I, Becker P: The effect of positive end-expiratory pressure on pulse pressure variation. South Afr J Anaesth Analg 2012, 18: 333-338.
30.
go back to reference Beda A, Carvalho NC, Guldner A, Koch T, de Abreu MG: Mechanical ventilation during anaesthesia: challenges and opportunities for investigating the respiration-related cardiovascular oscillations. Biomed Tech (Berl) 2011, 56: 195-206.CrossRef Beda A, Carvalho NC, Guldner A, Koch T, de Abreu MG: Mechanical ventilation during anaesthesia: challenges and opportunities for investigating the respiration-related cardiovascular oscillations. Biomed Tech (Berl) 2011, 56: 195-206.CrossRef
31.
go back to reference Guyton AC, Lindsey AW, Kaufmann BN: Effect of mean circulatory filling pressure and other peripheral circulatory factors on cardiac output. Am J Physiol 1955, 180: 463-468.PubMed Guyton AC, Lindsey AW, Kaufmann BN: Effect of mean circulatory filling pressure and other peripheral circulatory factors on cardiac output. Am J Physiol 1955, 180: 463-468.PubMed
32.
go back to reference Gelman S: Venous function and central venous pressure: a physiologic story. Anesthesiology 2008, 108: 735-748. 10.1097/ALN.0b013e3181672607CrossRefPubMed Gelman S: Venous function and central venous pressure: a physiologic story. Anesthesiology 2008, 108: 735-748. 10.1097/ALN.0b013e3181672607CrossRefPubMed
34.
go back to reference Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B: Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a 'gray zone’ approach. Anesthesiology 2011, 115: 231-241. 10.1097/ALN.0b013e318225b80aCrossRefPubMed Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B: Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a 'gray zone’ approach. Anesthesiology 2011, 115: 231-241. 10.1097/ALN.0b013e318225b80aCrossRefPubMed
35.
go back to reference Le Manach Y, Hofer CK, Lehot JJ, Vallet B, Goarin JP, Tavernier B, Cannesson M: Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period? Anesthesiology 2012, 117: 1165-1174. 10.1097/ALN.0b013e318275561dCrossRefPubMed Le Manach Y, Hofer CK, Lehot JJ, Vallet B, Goarin JP, Tavernier B, Cannesson M: Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period? Anesthesiology 2012, 117: 1165-1174. 10.1097/ALN.0b013e318275561dCrossRefPubMed
37.
go back to reference Takala J: Hemodynamic management of the critically ill patient: craft meets science. Curr Opin Crit Care 2007, 13: 519-520. 10.1097/MCC.0b013e3282f00f1fCrossRefPubMed Takala J: Hemodynamic management of the critically ill patient: craft meets science. Curr Opin Crit Care 2007, 13: 519-520. 10.1097/MCC.0b013e3282f00f1fCrossRefPubMed
38.
go back to reference Challand C, Struthers R, Sneyd JR, Erasmus PD, Mellor N, Hosie KB, Minto G: Randomized controlled trial of intraoperative goal-directed fluid therapy in aerobically fit and unfit patients having major colorectal surgery. Br J Anaesth 2012, 108: 53-62. 10.1093/bja/aer273CrossRefPubMed Challand C, Struthers R, Sneyd JR, Erasmus PD, Mellor N, Hosie KB, Minto G: Randomized controlled trial of intraoperative goal-directed fluid therapy in aerobically fit and unfit patients having major colorectal surgery. Br J Anaesth 2012, 108: 53-62. 10.1093/bja/aer273CrossRefPubMed
39.
go back to reference Bundgaard-Nielsen M, Jorgensen CC, Secher NH, Kehlet H: Functional intravascular volume deficit in patients before surgery. Acta Anaesthesiol Scand 2010, 54: 464-469. 10.1111/j.1399-6576.2009.02175.xCrossRefPubMed Bundgaard-Nielsen M, Jorgensen CC, Secher NH, Kehlet H: Functional intravascular volume deficit in patients before surgery. Acta Anaesthesiol Scand 2010, 54: 464-469. 10.1111/j.1399-6576.2009.02175.xCrossRefPubMed
41.
go back to reference Pinsky MR: Using ventilation-induced aortic pressure and flow variation to diagnose preload responsiveness. Intensive Care Med 2004, 30: 1008-1010. 10.1007/s00134-004-2208-6CrossRefPubMed Pinsky MR: Using ventilation-induced aortic pressure and flow variation to diagnose preload responsiveness. Intensive Care Med 2004, 30: 1008-1010. 10.1007/s00134-004-2208-6CrossRefPubMed
42.
go back to reference MacLean LD, Duff JH: The use of central venous pressure as a guide to volume replacement in shock. Chest 1965, 48: 199-205. 10.1378/chest.48.2.199CrossRef MacLean LD, Duff JH: The use of central venous pressure as a guide to volume replacement in shock. Chest 1965, 48: 199-205. 10.1378/chest.48.2.199CrossRef
43.
go back to reference Payen D: Prediction of fluid challenge effect: filling pressure when left ventricular function is abnormal, diastolic volume when left ventricular function is normal. Crit Care 2011, 15: 139. 10.1186/cc10067PubMedCentralCrossRefPubMed Payen D: Prediction of fluid challenge effect: filling pressure when left ventricular function is abnormal, diastolic volume when left ventricular function is normal. Crit Care 2011, 15: 139. 10.1186/cc10067PubMedCentralCrossRefPubMed
Metadata
Title
Pavane for a pulse pressure variation defunct
Author
Soren Sondergaard
Publication date
01-12-2013
Publisher
BioMed Central
Published in
Critical Care / Issue 6/2013
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc13109

Other articles of this Issue 6/2013

Critical Care 6/2013 Go to the issue