Skip to main content
Top
Published in: Journal of Gastrointestinal Surgery 5/2007

01-05-2007

Pathologic Correlation Study of Microwave Coagulation Therapy for Hepatic Malignancies Using a Three-Ring Probe

Authors: Perry Shen, Kim R. Geisinger, Ronald Zagoria, Edward A. Levine

Published in: Journal of Gastrointestinal Surgery | Issue 5/2007

Login to get access

Abstract

Microwave coagulation therapy (MCT) for the ablation of unresectable hepatic malignancies is a promising alternative to radiofrequency and cryoablation techniques. There are few data on the clinical effectiveness of MCT. In vivo pathologic evaluation of ablated tumor tissue is not well described for the three-ring microwave probe. The study design was a prospective trial enrolling patients with resectable hepatic malignancies. Lesions underwent in vivo MCT with the three-ring probe prior to liver resection. Gross and histologic evaluations of the tumor were performed, including nicotinamide adenine dinucleotide (NADH) vital staining. A total of nine patients with metastatic colon cancer were enrolled and had NADH stains performed of their pathologic specimens. The median size of the metastasis being ablated was 3.5 cm (range, 1.5–12.3). Fifty-six percent of the tumors demonstrated evidence of spontaneous coagulative necrosis on immediate histologic examination. The median dimensions of the ablation zones were 5 cm (range, 3–7) × 4.5 cm (range, 2.5–5.2) × 4.2 cm (range, 2–5) with a 5-min ablation at 60 W. The median ablation volume was 50.6 cm3 (range, 9–78). NADH vital staining was performed of the ablation zones with 100% absence of staining in the tumor tissue and in benign hepatic parenchyma, which is consistent with irreversible cellular damage. In conclusion, in vivo MCT of hepatic malignancies with the three-ring probe produces nonviable tumor cells after a 5-min ablation. The ablation time is significantly shorter than other available ablative techniques. Immediate histologic exam produces some evidence of coagulative necrosis. Further study of this promising technology is warranted.
Literature
1.
go back to reference Cance WG, Stewart AK, Menck HR. The national cancer data base report on treatment patterns for hepatocellular carcinomas: Improved survival of surgically resected patients, 1985–1996. Cancer 2000;88:912–920.PubMedCrossRef Cance WG, Stewart AK, Menck HR. The national cancer data base report on treatment patterns for hepatocellular carcinomas: Improved survival of surgically resected patients, 1985–1996. Cancer 2000;88:912–920.PubMedCrossRef
2.
go back to reference Kavolius JM, Fong YM, Blumgart LHM. Surgical resection of metastatic liver tumors. Surgical Oncology Clinics of North America 1996;5:337–353.PubMed Kavolius JM, Fong YM, Blumgart LHM. Surgical resection of metastatic liver tumors. Surgical Oncology Clinics of North America 1996;5:337–353.PubMed
3.
go back to reference Steele G Jr, Ravikumar TS. Resection of hepatic metastases from colorectal cancer: Biologic perspectives. Annals of Surgery 1989;210:127–138.PubMedCrossRef Steele G Jr, Ravikumar TS. Resection of hepatic metastases from colorectal cancer: Biologic perspectives. Annals of Surgery 1989;210:127–138.PubMedCrossRef
4.
5.
go back to reference Bilchik AJ, Wood TF, Allegra D, Tsioulias GJ, Chung M, Rose DM, et al. Cryosurgical ablation and radiofrequency ablation for unresectable hepatic malignant neoplasms: A proposed algorithm. Archives of Surgery 2000;135:657–662.PubMedCrossRef Bilchik AJ, Wood TF, Allegra D, Tsioulias GJ, Chung M, Rose DM, et al. Cryosurgical ablation and radiofrequency ablation for unresectable hepatic malignant neoplasms: A proposed algorithm. Archives of Surgery 2000;135:657–662.PubMedCrossRef
6.
go back to reference Bleicher RJ, Allegra DP, Nora DT, Wood TF, Foshag LJ, Bilchik AJ. Radiofrequency ablation in 447 complex unresectable liver tumors: Lessons learned. Annals of Surgical Oncology 2003;10:52–58.PubMedCrossRef Bleicher RJ, Allegra DP, Nora DT, Wood TF, Foshag LJ, Bilchik AJ. Radiofrequency ablation in 447 complex unresectable liver tumors: Lessons learned. Annals of Surgical Oncology 2003;10:52–58.PubMedCrossRef
7.
go back to reference Wright AS, Lee FT, Mahvi DM. Hepatic microwave ablation with multiple antennae results in synergistically larger zones of coagulation necrosis. Annals of Surgical Oncology 2003;10:275–283.PubMedCrossRef Wright AS, Lee FT, Mahvi DM. Hepatic microwave ablation with multiple antennae results in synergistically larger zones of coagulation necrosis. Annals of Surgical Oncology 2003;10:275–283.PubMedCrossRef
8.
go back to reference Berber E, Herceg NL, Casto KJ, Siperstein AE. Laparoscopic radiofrequency ablation of hepatic tumors: Prospective clinical evaluation of ablation size comparing two treatment algorithms. Surgical Endoscopy 2004;18:390–396.PubMedCrossRef Berber E, Herceg NL, Casto KJ, Siperstein AE. Laparoscopic radiofrequency ablation of hepatic tumors: Prospective clinical evaluation of ablation size comparing two treatment algorithms. Surgical Endoscopy 2004;18:390–396.PubMedCrossRef
9.
go back to reference Lu DS, Raman SS, Vodopich DJ, Wang M, Sayre J, Lassman C. Effect of vessel size on creation of hepatic radiofrequency lesions in pigs: Assessment of the “heat sink” effect. AJR. American Journal of Roentgenology 2002;178:47–51.PubMed Lu DS, Raman SS, Vodopich DJ, Wang M, Sayre J, Lassman C. Effect of vessel size on creation of hepatic radiofrequency lesions in pigs: Assessment of the “heat sink” effect. AJR. American Journal of Roentgenology 2002;178:47–51.PubMed
10.
go back to reference Jiao LR, Habib NA. Experimental study of large-volume microwave ablation in the liver. British Journal of Surgery 2003;89:1003–1007. Jiao LR, Habib NA. Experimental study of large-volume microwave ablation in the liver. British Journal of Surgery 2003;89:1003–1007.
11.
go back to reference Wright AS, Sampson LA, Warner TF, Mahvi DM, Lee FT. Radiofrequency versus microwave ablation in a hepatic porcine model. Radiology 2005;236:132–139.PubMedCrossRef Wright AS, Sampson LA, Warner TF, Mahvi DM, Lee FT. Radiofrequency versus microwave ablation in a hepatic porcine model. Radiology 2005;236:132–139.PubMedCrossRef
12.
go back to reference Meredith K, Lee F, Henry MB, Warner T, Mahvi D. Microwave ablation of hepatic tumors using dual-loop probes: Results of a phase I clinical trial. Journal of Gastrointestinal Surgery 2005;9:1354–1360.PubMedCrossRef Meredith K, Lee F, Henry MB, Warner T, Mahvi D. Microwave ablation of hepatic tumors using dual-loop probes: Results of a phase I clinical trial. Journal of Gastrointestinal Surgery 2005;9:1354–1360.PubMedCrossRef
13.
go back to reference Shock SA, Meredith K, Warner TF, Sampson LA, Wright AS, Winter TC 3rd, et al. Microwave ablation with loop antenna: In vivo porcine liver model. Radiology 2004;231:143–149.PubMedCrossRef Shock SA, Meredith K, Warner TF, Sampson LA, Wright AS, Winter TC 3rd, et al. Microwave ablation with loop antenna: In vivo porcine liver model. Radiology 2004;231:143–149.PubMedCrossRef
14.
go back to reference Shibata T, Niinobu T, Ogata N. Comparison of the effects of in-vivo thermal ablation of pig liver by microwave and radiofrequency coagulation. Journal of Hepatobiliary Pancreatic Surgery 2000;7:592–598.PubMedCrossRef Shibata T, Niinobu T, Ogata N. Comparison of the effects of in-vivo thermal ablation of pig liver by microwave and radiofrequency coagulation. Journal of Hepatobiliary Pancreatic Surgery 2000;7:592–598.PubMedCrossRef
15.
go back to reference Goldberg SN, Gazelle GS, Compton CC, Mueller PR, Tanabe KK. Treatment of intrahepatic malignancy with radiofrequency ablation: Radiologic–pathologic correlation. Cancer 2000;88:2452–2463.PubMedCrossRef Goldberg SN, Gazelle GS, Compton CC, Mueller PR, Tanabe KK. Treatment of intrahepatic malignancy with radiofrequency ablation: Radiologic–pathologic correlation. Cancer 2000;88:2452–2463.PubMedCrossRef
16.
go back to reference Matlaga BR, Zagoria RJ, Woodruff RD, Torti FM, Hall MC. Phase II trial of radio frequency ablation of renal cancer: Evaluation of the kill zone. Journal of Urology 2002;68:2401–2405.PubMedCrossRef Matlaga BR, Zagoria RJ, Woodruff RD, Torti FM, Hall MC. Phase II trial of radio frequency ablation of renal cancer: Evaluation of the kill zone. Journal of Urology 2002;68:2401–2405.PubMedCrossRef
17.
go back to reference Simon CJ, Dupuy DE, Iannitti DA, Lu DS, Yu NC, Aswad BI, et al. Intraoperative triple antenna hepatic microwave ablation. American Journal of Roentgenology 2006;187:333–340.CrossRef Simon CJ, Dupuy DE, Iannitti DA, Lu DS, Yu NC, Aswad BI, et al. Intraoperative triple antenna hepatic microwave ablation. American Journal of Roentgenology 2006;187:333–340.CrossRef
18.
go back to reference Seki S, Sakaguchi H, Kadoya H, Morikawa H, Habu D, Nishiguchi S, et al. Laparoscopic microwave coagulation therapy for hepatocellular carcinoma. Endoscopy 2000;32:591–597.PubMedCrossRef Seki S, Sakaguchi H, Kadoya H, Morikawa H, Habu D, Nishiguchi S, et al. Laparoscopic microwave coagulation therapy for hepatocellular carcinoma. Endoscopy 2000;32:591–597.PubMedCrossRef
19.
go back to reference Ohmoto K, Miyake I, Tsuduki M, Shibata N, Takesue M, Kunieda T, et al. Percutaneous microwave coagulation therapy for unresectable hepatocellular carcinoma. Hepatogastroenterology 1999;46:2894–2900.PubMed Ohmoto K, Miyake I, Tsuduki M, Shibata N, Takesue M, Kunieda T, et al. Percutaneous microwave coagulation therapy for unresectable hepatocellular carcinoma. Hepatogastroenterology 1999;46:2894–2900.PubMed
Metadata
Title
Pathologic Correlation Study of Microwave Coagulation Therapy for Hepatic Malignancies Using a Three-Ring Probe
Authors
Perry Shen
Kim R. Geisinger
Ronald Zagoria
Edward A. Levine
Publication date
01-05-2007
Publisher
Springer-Verlag
Published in
Journal of Gastrointestinal Surgery / Issue 5/2007
Print ISSN: 1091-255X
Electronic ISSN: 1873-4626
DOI
https://doi.org/10.1007/s11605-006-0046-2

Other articles of this Issue 5/2007

Journal of Gastrointestinal Surgery 5/2007 Go to the issue