Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 4/2017

01-04-2017 | Cataract

Outcomes of femtosecond laser-assisted cataract surgery performed by surgeons-in-training

Authors: Greg Brunin, Khurrum Khan, Kristin S. Biggerstaff, Li Wang, Douglas D. Koch, Sumitra S. Khandelwal

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 4/2017

Login to get access

Abstract

Purpose

To compare intraoperative factors and post-operative outcomes of femtosecond laser-assisted cataract surgery (FLACS) and manual cataract surgery performed by resident surgeons.

Methods

All cases of FLACS performed by resident surgeons during the 2013–2014 academic year were compared to a control group of manual cataract surgery cases with regards to pre-operative patient data, operative complications, cumulative dissipated energy (CDE), postoperative corrected distance visual acuity (CDVA), refractive prediction error (RPE), and corneal edema.

Results

There were no significant preoperative differences in the FLACS (n = 57) and manual (n = 68) groups. Operative complication rates were similar in cases with sufficient data and follow-up with a higher rate of posterior capsule tear in the manual group. CDE (percent-seconds) was lower in the FLACS group (FLACS: 14.5 ± 7.5; manual: 21.6 ± 11.5; p < 0.01). CDVA (LogMAR) was comparable at 1 month postoperatively (FLACS: 0.004 ± 0.08; manual: 0.024 ± 0.11; p = 0.24) and 1 year postoperatively (FLACS: 0.013 ± 0.06; manual: 0.032 ± 0.09; p = 0.37). No difference in RPE was found at 1 month postoperatively (FLACS: 0.38 ± 0.24 D; manual: 0.41 ± 0.49 D; p = 0.66) and 1 year postoperatively (FLACS: 0.49 ± 0.63 D; manual: 0.34 ± 0.26 D; p = 0.31).

Conclusions

Femtosecond laser-assisted cataract surgery is safe and effective compared to manual cataract surgery when performed by resident surgeons. Both 1-month and 1-year outcomes show no difference in refractive predictive error in FLACS compared to manual cataract surgery in surgeons in training.
Literature
1.
go back to reference Nagy Z (2014) New technology update: femtosecond laser in cataract surgery. Clin Ophthalmol 201:1157–1167CrossRef Nagy Z (2014) New technology update: femtosecond laser in cataract surgery. Clin Ophthalmol 201:1157–1167CrossRef
2.
go back to reference Linebarger EJ et al (1999) Phacoemulsification and modern cataract surgery. Surv Ophthalmol 44:123–147CrossRefPubMed Linebarger EJ et al (1999) Phacoemulsification and modern cataract surgery. Surv Ophthalmol 44:123–147CrossRefPubMed
3.
go back to reference Abell RG et al (2013) Femtosecond laser-assisted cataract surgery compared with manual cataract surgery. Clin Exp Ophthalmol 41:455–462CrossRefPubMed Abell RG et al (2013) Femtosecond laser-assisted cataract surgery compared with manual cataract surgery. Clin Exp Ophthalmol 41:455–462CrossRefPubMed
4.
go back to reference Chee SP et al (2015) Clinical outcomes in the first two years of femtosecond laser-assisted cataract surgery. Am J Ophthalmol 159:714–719CrossRefPubMed Chee SP et al (2015) Clinical outcomes in the first two years of femtosecond laser-assisted cataract surgery. Am J Ophthalmol 159:714–719CrossRefPubMed
5.
go back to reference Chen M et al (2015) Comparing the intraoperative complication rate of femtosecond laser-assisted cataract surgery to traditional phacoemulsification. Int J Ophthalmol 8:201–203PubMedPubMedCentral Chen M et al (2015) Comparing the intraoperative complication rate of femtosecond laser-assisted cataract surgery to traditional phacoemulsification. Int J Ophthalmol 8:201–203PubMedPubMedCentral
6.
go back to reference Conrad-Hengerer I et al (2012) Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery. J Refract Surg 28:879–883CrossRefPubMed Conrad-Hengerer I et al (2012) Effect of femtosecond laser fragmentation on effective phacoemulsification time in cataract surgery. J Refract Surg 28:879–883CrossRefPubMed
7.
go back to reference Abell RG et al (2013) Toward zero effective phacoemulsification time using femtosecond laser pretreatment. Ophthalmology 120:942–948CrossRefPubMed Abell RG et al (2013) Toward zero effective phacoemulsification time using femtosecond laser pretreatment. Ophthalmology 120:942–948CrossRefPubMed
8.
go back to reference Mastropasqua L et al (2014) Femtosecond laser versus manual clear corneal incision in cataract surgery. J Refract Surg 30:27–33CrossRefPubMed Mastropasqua L et al (2014) Femtosecond laser versus manual clear corneal incision in cataract surgery. J Refract Surg 30:27–33CrossRefPubMed
9.
go back to reference Abell RG et al (2014) Effect of femtosecond laser-assisted cataract surgery on the corneal endothelium. J Cataract Refract Surg 40:1777–1783CrossRefPubMed Abell RG et al (2014) Effect of femtosecond laser-assisted cataract surgery on the corneal endothelium. J Cataract Refract Surg 40:1777–1783CrossRefPubMed
10.
go back to reference Day AC et al (2014) Efficacy of anterior capsulotomy creation in femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:2031–2034CrossRefPubMed Day AC et al (2014) Efficacy of anterior capsulotomy creation in femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:2031–2034CrossRefPubMed
11.
go back to reference Kranitz K et al (2011) Femtosecond laser capsulotomy and manual continuous curvilinear capsulorrhexis and their effects on intraocular lens centration. J Refract Surg 27:558–563CrossRefPubMed Kranitz K et al (2011) Femtosecond laser capsulotomy and manual continuous curvilinear capsulorrhexis and their effects on intraocular lens centration. J Refract Surg 27:558–563CrossRefPubMed
12.
go back to reference Filkorn T et al (2012) Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification. J Refract Surg 28:540–544CrossRefPubMed Filkorn T et al (2012) Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification. J Refract Surg 28:540–544CrossRefPubMed
13.
go back to reference Kranitz K et al (2012) Intraocular lens tilt and decentration measured by Schiempflug camera following manual or femtosecond laser-created continuous circular capsulotomy. J Refract Surg 28:259–263CrossRefPubMed Kranitz K et al (2012) Intraocular lens tilt and decentration measured by Schiempflug camera following manual or femtosecond laser-created continuous circular capsulotomy. J Refract Surg 28:259–263CrossRefPubMed
14.
go back to reference Abell RG et al (2014) Cost-effectiveness of femtosecond laser-assisted cataract surgery versus phacoemulsification cataract surgery. Ophthalmology 121:10–16CrossRefPubMed Abell RG et al (2014) Cost-effectiveness of femtosecond laser-assisted cataract surgery versus phacoemulsification cataract surgery. Ophthalmology 121:10–16CrossRefPubMed
15.
go back to reference Lubahn JG et al (2014) Operating times of experienced cataract surgeons beginning femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:1773–1776CrossRefPubMed Lubahn JG et al (2014) Operating times of experienced cataract surgeons beginning femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:1773–1776CrossRefPubMed
16.
go back to reference Abell RG et al (2015) Femtosecond laser-assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4,000 cases at a single center. J Cataract Refract Surg 41:47–52CrossRefPubMed Abell RG et al (2015) Femtosecond laser-assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4,000 cases at a single center. J Cataract Refract Surg 41:47–52CrossRefPubMed
17.
go back to reference Nagy Z et al (2014) The use of femtosecond lasers in cataract surgery: review of published results with the LenSx system. J Refract Surg 30:730–740CrossRefPubMed Nagy Z et al (2014) The use of femtosecond lasers in cataract surgery: review of published results with the LenSx system. J Refract Surg 30:730–740CrossRefPubMed
18.
go back to reference Bali S et al (2012) Early experience with the femtosecond laser for cataract surgery. Ophthalmology 119:891–899CrossRefPubMed Bali S et al (2012) Early experience with the femtosecond laser for cataract surgery. Ophthalmology 119:891–899CrossRefPubMed
19.
go back to reference Roberts T et al (2013) Surgical outcomes and safety of femtosecond laser cataract surgery. Ophthalmology 120:227–233CrossRefPubMed Roberts T et al (2013) Surgical outcomes and safety of femtosecond laser cataract surgery. Ophthalmology 120:227–233CrossRefPubMed
20.
go back to reference Nagy Z et al (2014) Complications of femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:20–28CrossRefPubMed Nagy Z et al (2014) Complications of femtosecond laser-assisted cataract surgery. J Cataract Refract Surg 40:20–28CrossRefPubMed
21.
go back to reference Randelman J et al (2007) The resident surgeon phacoemulsification learning curve. Arch Ophthalmol 125:1215–1219CrossRef Randelman J et al (2007) The resident surgeon phacoemulsification learning curve. Arch Ophthalmol 125:1215–1219CrossRef
22.
go back to reference Cohen M et al (2015) Femtosecond laser-assisted cataract surgery in residency training. Current Opinions Ophthalmol 26:56–60CrossRef Cohen M et al (2015) Femtosecond laser-assisted cataract surgery in residency training. Current Opinions Ophthalmol 26:56–60CrossRef
23.
go back to reference Hou J et al (2015) Safety of femtosecond laser-assisted cataract surgery performed by surgeons in training. J Refract Surg 31:69–70CrossRefPubMed Hou J et al (2015) Safety of femtosecond laser-assisted cataract surgery performed by surgeons in training. J Refract Surg 31:69–70CrossRefPubMed
Metadata
Title
Outcomes of femtosecond laser-assisted cataract surgery performed by surgeons-in-training
Authors
Greg Brunin
Khurrum Khan
Kristin S. Biggerstaff
Li Wang
Douglas D. Koch
Sumitra S. Khandelwal
Publication date
01-04-2017
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 4/2017
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-016-3581-x

Other articles of this Issue 4/2017

Graefe's Archive for Clinical and Experimental Ophthalmology 4/2017 Go to the issue

Acknowledgement to referees

Thank you list 2016