Abstract

Purpose

The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device.

Methods

Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score.

Results

All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points.

Conclusions

For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries.
Literature
2.
go back to reference Self J, Viegas SF, Buford WL Jr, Patterson RM (1995) A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg 4(1 Pt 1):10–16PubMedCrossRef Self J, Viegas SF, Buford WL Jr, Patterson RM (1995) A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg 4(1 Pt 1):10–16PubMedCrossRef
3.
go back to reference Waddell JP, Hatch J, Richards R (1988) Supracondylar fractures of the humerus–results of surgical treatment. J Trauma 28(12):1615–1621PubMedCrossRef Waddell JP, Hatch J, Richards R (1988) Supracondylar fractures of the humerus–results of surgical treatment. J Trauma 28(12):1615–1621PubMedCrossRef
4.
go back to reference Korner J, Lill H, Müller LP, Hessmann M, Kopf K, Goldhahn J, Gonschorek O, Josten C, Rommens PM (2005) Distal humerus fractures in elderly patients: results after open reduction and internal fixation. Osteoporos Int 16(Suppl 2):S73–S79. doi:10.1007/s00198-004-1764-5 PubMedCrossRef Korner J, Lill H, Müller LP, Hessmann M, Kopf K, Goldhahn J, Gonschorek O, Josten C, Rommens PM (2005) Distal humerus fractures in elderly patients: results after open reduction and internal fixation. Osteoporos Int 16(Suppl 2):S73–S79. doi:10.​1007/​s00198-004-1764-5 PubMedCrossRef
5.
go back to reference Levy JC, Kalandiak SP, Hutson JJ, Zych G (2005) An alternative method of osteosynthesis for distal humeral shaft fractures. J Orthop Trauma 19(1):43–47PubMedCrossRef Levy JC, Kalandiak SP, Hutson JJ, Zych G (2005) An alternative method of osteosynthesis for distal humeral shaft fractures. J Orthop Trauma 19(1):43–47PubMedCrossRef
7.
go back to reference Korner J, Diederichs G, Arzdorf M, Lill H, Josten C, Schneider E, Linke B (2004) A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma 18(5):286–293PubMedCrossRef Korner J, Diederichs G, Arzdorf M, Lill H, Josten C, Schneider E, Linke B (2004) A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J Orthop Trauma 18(5):286–293PubMedCrossRef
8.
go back to reference Jawa A, McCarty P, Doornberg J, Harris M, Ring D (2006) Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 88(11):2343–2347. doi:10.2106/JBJS.F.00334 PubMedCrossRef Jawa A, McCarty P, Doornberg J, Harris M, Ring D (2006) Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J Bone Joint Surg Am 88(11):2343–2347. doi:10.​2106/​JBJS.​F.​00334 PubMedCrossRef
9.
go back to reference Paris H, Tropiano P, Clouet D'orval B, Chaudet H, Poitout DG (2000) Fractures of the shaft of the humerus: systematic plate fixation. Anatomic and functional results in 156 cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 86(4):346–359PubMed Paris H, Tropiano P, Clouet D'orval B, Chaudet H, Poitout DG (2000) Fractures of the shaft of the humerus: systematic plate fixation. Anatomic and functional results in 156 cases and a review of the literature. Rev Chir Orthop Reparatrice Appar Mot 86(4):346–359PubMed
10.
go back to reference Moran MC (1997) Modified lateral approach to the distal humerus for internal fixation. Clin Orthop Relat Res 340:190–197 Moran MC (1997) Modified lateral approach to the distal humerus for internal fixation. Clin Orthop Relat Res 340:190–197
11.
go back to reference Egol KA, Su E, Tejwani NC, Sims SH, Kummer FJ, Koval KJ (2004) Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma 57(2):340–346PubMedCrossRef Egol KA, Su E, Tejwani NC, Sims SH, Kummer FJ, Koval KJ (2004) Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma 57(2):340–346PubMedCrossRef
13.
go back to reference Kregor PJ, Stannard JA, Zlowodzki M, Cole PA (2004) Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures. J Orthop Trauma 18(8):509–520PubMedCrossRef Kregor PJ, Stannard JA, Zlowodzki M, Cole PA (2004) Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures. J Orthop Trauma 18(8):509–520PubMedCrossRef
14.
go back to reference Cole PA, Zlowodzki M, Kregor PJ (2004) Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma 18(8):528–535PubMedCrossRef Cole PA, Zlowodzki M, Kregor PJ (2004) Treatment of proximal tibia fractures using the less invasive stabilization system: surgical experience and early clinical results in 77 fractures. J Orthop Trauma 18(8):528–535PubMedCrossRef
15.
go back to reference Bedi A, Le TT, Karunakar MA (2006) Surgical treatment of nonarticular distal tibia fractures. J Am Acad Orthop Surg 14(7):406–416PubMed Bedi A, Le TT, Karunakar MA (2006) Surgical treatment of nonarticular distal tibia fractures. J Am Acad Orthop Surg 14(7):406–416PubMed
17.
go back to reference Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78(11):1690–1695PubMed Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78(11):1690–1695PubMed
18.
go back to reference Robinson CM, Hill RM, Jacobs N, Dall G, Court-Brown CM (2003) Adult distal humeral metaphyseal fractures: epidemiology and results of treatment. J Orthop Trauma 17(1):38–47PubMedCrossRef Robinson CM, Hill RM, Jacobs N, Dall G, Court-Brown CM (2003) Adult distal humeral metaphyseal fractures: epidemiology and results of treatment. J Orthop Trauma 17(1):38–47PubMedCrossRef
19.
go back to reference Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ (2009) Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma 66(3):795–799. doi:10.1097/TA.0b013e318181e53c PubMedCrossRef Tejwani NC, Murthy A, Park J, McLaurin TM, Egol KA, Kummer FJ (2009) Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study. J Trauma 66(3):795–799. doi:10.​1097/​TA.​0b013e318181e53c​ PubMedCrossRef
21.
22.
go back to reference Greiner S, Haas NP, Bail HJ (2008) Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Arch Orthop Trauma Surg 128(7):723–729. doi:10.1007/s00402-007-0428-2 PubMedCrossRef Greiner S, Haas NP, Bail HJ (2008) Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Arch Orthop Trauma Surg 128(7):723–729. doi:10.​1007/​s00402-007-0428-2 PubMedCrossRef
24.
go back to reference Wenzl ME, Porté T, Fuchs S, Faschingbauer M, Jürgens C (2004) Delayed and non-union of the humeral diaphysis–compression plate or internal plate fixator? Injury 35(1):55–60PubMedCrossRef Wenzl ME, Porté T, Fuchs S, Faschingbauer M, Jürgens C (2004) Delayed and non-union of the humeral diaphysis–compression plate or internal plate fixator? Injury 35(1):55–60PubMedCrossRef
25.
go back to reference Aggarwal S, Kumar V, Bhagwat KR, Behera P (2013) AO extra-articular distal humerus locking plate: extended spectrum of usage in intra-articular distal fractures with metaphyseal extension-our experience with 20 cases. Eur J Orthop Surg Traumatol. doi:10.1007/s00590-013-1217-y PubMed Aggarwal S, Kumar V, Bhagwat KR, Behera P (2013) AO extra-articular distal humerus locking plate: extended spectrum of usage in intra-articular distal fractures with metaphyseal extension-our experience with 20 cases. Eur J Orthop Surg Traumatol. doi:10.​1007/​s00590-013-1217-y PubMed
Metadata
Title
Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate
Authors
John T. Capo
Monika P. Debkowska
Frank Liporace
Bryan G. Beutel
Eitan Melamed
Publication date
01-05-2014
Publisher
Springer Berlin Heidelberg
Published in
International Orthopaedics / Issue 5/2014
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2213-x

Other articles of this Issue 5/2014

International Orthopaedics 5/2014 Go to the issue