Skip to main content
Top
Published in: International Orthopaedics 6/2009

01-12-2009 | Original Paper

Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement

Authors: Ian Holloway, William L. Walter, Bernie Zicat, William K. Walter

Published in: International Orthopaedics | Issue 6/2009

Login to get access

Abstract

This study examined the long-term results of a metal-on-metal total hip replacement with a Metasul-lined cup. Twenty-nine total hip arthroplasties were performed in 27 young patients (mean age 49 years). Twenty-two patients (23 hips) were available for clinical and radiographic analysis after a mean duration of 99 months. Mean preoperative Harris hip score of 60 improved to 93 at most recent follow-up. One patient required revision of his cup for periacetabular osteolysis. Radiographic analysis showed osteolysis in another four hips. The high rate of osteolysis found in this series has not previously been reported with this type of implant. The length of follow-up in this series is greater than other reports in the literature and may explain this difference.
Literature
1.
go back to reference Cozzolino FMM, Costa L, Scognamiglio D, Cozzolino A, Marino D, Milano C (2002) A comparative study on medium-term results of cementless acetabular components with metal-on-metal and metal-on-polyethylene articulations. J Orthopaed Traumatol 2(3):129–133 Cozzolino FMM, Costa L, Scognamiglio D, Cozzolino A, Marino D, Milano C (2002) A comparative study on medium-term results of cementless acetabular components with metal-on-metal and metal-on-polyethylene articulations. J Orthopaed Traumatol 2(3):129–133
2.
go back to reference Delaunay CP (2004) Metal-on-metal bearings in cementless primary total hip arthroplasty. J Arthroplasty 19(Suppl 3):8 Delaunay CP (2004) Metal-on-metal bearings in cementless primary total hip arthroplasty. J Arthroplasty 19(Suppl 3):8
3.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32 DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32
4.
go back to reference Dorr LD, Hilton KR, Wan Z, Markovich GD, Bloebaum R (1996) Modern metal on metal articulation for total hip replacements. Clin Orthop Relat Res 333:108–117 Dorr LD, Hilton KR, Wan Z, Markovich GD, Bloebaum R (1996) Modern metal on metal articulation for total hip replacements. Clin Orthop Relat Res 333:108–117
5.
go back to reference Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R (2000) Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg Am 82:6 Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R (2000) Total hip arthroplasty with use of the Metasul metal-on-metal articulation. Four to seven-year results. J Bone Joint Surg Am 82:6
6.
go back to reference Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:4 Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am 51:4
7.
go back to reference Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am 87:4CrossRef Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am 87:4CrossRef
8.
go back to reference Jacobs JJ, Hallab NJ (2006) Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity? J Bone Joint Surg Am 88:6 Jacobs JJ, Hallab NJ (2006) Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity? J Bone Joint Surg Am 88:6
9.
go back to reference Johnston RC, Fitzgerald RH Jr., Harris WH, Poss R, Muller ME, Sledge CB (1990) Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 72:2 Johnston RC, Fitzgerald RH Jr., Harris WH, Poss R, Muller ME, Sledge CB (1990) Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 72:2
10.
go back to reference Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY (2004) Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am 86:11CrossRef Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY (2004) Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am 86:11CrossRef
11.
go back to reference Kitamura N, Naudie DD, Leung SB, Hopper RH Jr., Engh CA Sr. (2005) Diagnostic features of pelvic osteolysis on computed tomography: the importance of communication pathways. J Bone Joint Surg Am 87:7CrossRef Kitamura N, Naudie DD, Leung SB, Hopper RH Jr., Engh CA Sr. (2005) Diagnostic features of pelvic osteolysis on computed tomography: the importance of communication pathways. J Bone Joint Surg Am 87:7CrossRef
12.
go back to reference Klapperich C, Graham J, Pruitt L, Ries MD (1999) Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis. J Arthroplasty 14:7CrossRef Klapperich C, Graham J, Pruitt L, Ries MD (1999) Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis. J Arthroplasty 14:7CrossRef
13.
go back to reference Lazennec JL, Boyer PJ, Rousseau MA, Laude F, Catonne Y, Saillant G (2007) Poor eight year survival of second generation metal-on-metal cemented total hip arthroplasty. Presented at the annual meeting of the American Academy of Orthopaedic Surgeons, San Diego, CA Lazennec JL, Boyer PJ, Rousseau MA, Laude F, Catonne Y, Saillant G (2007) Poor eight year survival of second generation metal-on-metal cemented total hip arthroplasty. Presented at the annual meeting of the American Academy of Orthopaedic Surgeons, San Diego, CA
14.
go back to reference Migaud H, Jobin A, Chantelot C, Giraud F, Laffargue P, Duquennoy A (2004) Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up. J Arthroplasty 19(Suppl 3):8 Migaud H, Jobin A, Chantelot C, Giraud F, Laffargue P, Duquennoy A (2004) Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up. J Arthroplasty 19(Suppl 3):8
15.
go back to reference Milosev I, Trebse R, Kovac S, Cor A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:6CrossRef Milosev I, Trebse R, Kovac S, Cor A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:6CrossRef
16.
go back to reference Prakash U, Mulgrew S, Espley AJ (1999) Effect of activity levels on polyethylene wear in Charnley low-friction arthroplasty. J R Coll Surg Edinb 44:3 Prakash U, Mulgrew S, Espley AJ (1999) Effect of activity levels on polyethylene wear in Charnley low-friction arthroplasty. J R Coll Surg Edinb 44:3
17.
go back to reference Szuszczewicz ES, Schmalzried TP, Petersen TD (1997) Progressive bilateral pelvic osteolysis in a patient with McKee-Farrar metal-metal total hip prostheses. J Arthroplasty 12:7CrossRef Szuszczewicz ES, Schmalzried TP, Petersen TD (1997) Progressive bilateral pelvic osteolysis in a patient with McKee-Farrar metal-metal total hip prostheses. J Arthroplasty 12:7CrossRef
18.
go back to reference Wagner M, Wagner H (2000) Medium-term results of a modern metal-on-metal system in total hip replacement. Clin Orthop Relat Res 379:123–133 Wagner M, Wagner H (2000) Medium-term results of a modern metal-on-metal system in total hip replacement. Clin Orthop Relat Res 379:123–133
19.
go back to reference Walter WL, Clabeaux J, Wright TM, Walsh W, Walter WK, Sculco TP (2005) Mechanisms for pumping fluid through cementless acetabular components with holes. J Arthroplasty 20:8CrossRef Walter WL, Clabeaux J, Wright TM, Walsh W, Walter WK, Sculco TP (2005) Mechanisms for pumping fluid through cementless acetabular components with holes. J Arthroplasty 20:8CrossRef
20.
go back to reference Walter WL, Walter WK, O’Sullivan M (2004) The pumping of fluid in cementless cups with holes. J Arthroplasty 19:2 Walter WL, Walter WK, O’Sullivan M (2004) The pumping of fluid in cementless cups with holes. J Arthroplasty 19:2
21.
go back to reference Wasielewski RC, Jacobs JJ, Arthurs B, Rubash HE (2005) The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty 20:7CrossRef Wasielewski RC, Jacobs JJ, Arthurs B, Rubash HE (2005) The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty 20:7CrossRef
22.
go back to reference Weber BG (1996) Experience with the Metasul total hip bearing system. Clin Orthop Relat Res 329(Suppl):69–77 Weber BG (1996) Experience with the Metasul total hip bearing system. Clin Orthop Relat Res 329(Suppl):69–77
23.
go back to reference Willert HG, Bertram H, Buchhorn GH (1990) Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop Relat Res 258:108–121 Willert HG, Bertram H, Buchhorn GH (1990) Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop Relat Res 258:108–121
24.
go back to reference Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87:1CrossRef Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87:1CrossRef
25.
go back to reference Young AM, Sychterz CJ, Hopper RH Jr., Engh CA (2002) Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84:1CrossRef Young AM, Sychterz CJ, Hopper RH Jr., Engh CA (2002) Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am 84:1CrossRef
26.
go back to reference Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:3 Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:3
Metadata
Title
Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement
Authors
Ian Holloway
William L. Walter
Bernie Zicat
William K. Walter
Publication date
01-12-2009
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 6/2009
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0679-8

Other articles of this Issue 6/2009

International Orthopaedics 6/2009 Go to the issue