Skip to main content
Top
Published in: Journal of Digital Imaging 6/2013

01-12-2013

Optimization of Computed Tomography Protocols: Limitations of a Methodology Employing a Phantom with Location-Known Opacities

Authors: Karen L. Dobeli, Sarah J. Lewis, Steven R. Meikle, David L. Thiele, Patrick C. Brennan

Published in: Journal of Imaging Informatics in Medicine | Issue 6/2013

Login to get access

Abstract

This study aimed to determine if phantom-based methodologies for optimization of hepatic lesion detection with computed tomography (CT) require randomization of lesion placement and inclusion of normal images. A phantom containing fixed opacities of varying size (diameters, 2.4, 4.8, and 9.5 mm) was scanned at various exposure and slice thickness settings. Two image sets were compared: All images in the first image set contained opacities with known location; the second image set contained images with opacities in random locations. Following Institutional Review Board approval, nine experienced observers scored opacity visualization using a 4-point confidence scale. Comparisons between image sets were performed using Spearman, Kappa, and Wilcoxon techniques. Observer scores demonstrated strong correlation between both approaches when all opacity sizes were combined (r = 0.92, p < 0.0001), for the 9.5 mm opacity (r = 0.96, p < 0.0001) and for the 2.4 mm opacity (r = 0.64, p < 0.05). There was no significant correlation for the 4.8 mm opacity. A significantly higher sensitivity score for the known compared with the unknown location was found for the 9.5 mm opacity and 4.8 mm opacity for a single slice thickness and exposure condition (p < 0.05). Phantom-based optimization of CT hepatic examinations requires randomized lesion location when investigating challenging conditions; however, a standard phantom with fixed lesion location is suitable for the optimization of routine liver protocols. The development of more sophisticated phantoms or methods than those currently available is indicated for the optimization of CT protocols for diagnostic tasks involving the detection of subtle change.
Literature
1.
go back to reference Wise K, Thomson J: Changes in CT radiation doses in Australia from 1994–2002. The Radiographer 51:81–85, 2004 Wise K, Thomson J: Changes in CT radiation doses in Australia from 1994–2002. The Radiographer 51:81–85, 2004
2.
go back to reference Kaul A, Bauer B, Bernhardt J, Nosske D, Veit R: Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany. Eur Radiol 7:1127–1132, 1997PubMedCrossRef Kaul A, Bauer B, Bernhardt J, Nosske D, Veit R: Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany. Eur Radiol 7:1127–1132, 1997PubMedCrossRef
3.
go back to reference Mettler Jr, FA, Wiest PW, Locken JA, Kelsey CA: CT scanning: patterns of use and dose. J Radiol Prot 20:353–359, 2000PubMedCrossRef Mettler Jr, FA, Wiest PW, Locken JA, Kelsey CA: CT scanning: patterns of use and dose. J Radiol Prot 20:353–359, 2000PubMedCrossRef
4.
go back to reference Hart D, Wall B: Radiation exposure of the UK population from medical and dental x-ray examinations. Chilton: National Radiological Protection Board, Report No. NRPB-W4, 2002 Hart D, Wall B: Radiation exposure of the UK population from medical and dental x-ray examinations. Chilton: National Radiological Protection Board, Report No. NRPB-W4, 2002
5.
go back to reference Aroua A, Burnand B, Decka I, Vader JP, Valley JF: Nation-wide survey on radiation doses in diagnostic and interventional radiology in Switzerland in 1998. Health Phys 83:46–55, 2002PubMedCrossRef Aroua A, Burnand B, Decka I, Vader JP, Valley JF: Nation-wide survey on radiation doses in diagnostic and interventional radiology in Switzerland in 1998. Health Phys 83:46–55, 2002PubMedCrossRef
6.
go back to reference Bongartz G, Golding SJ, Jurik A, Leonardi M, van Persijn van Meerten E, Rodriquez R, Schneider K, Calzado A, Geleijns A, Jessen J, Panzer KA, Shrimpton PC, Tosi G: European Guidelines for multislice computed tomography. European Commission, contract no. FIGM-CT2000-20078-CT-TIP, 2004 Bongartz G, Golding SJ, Jurik A, Leonardi M, van Persijn van Meerten E, Rodriquez R, Schneider K, Calzado A, Geleijns A, Jessen J, Panzer KA, Shrimpton PC, Tosi G: European Guidelines for multislice computed tomography. European Commission, contract no. FIGM-CT2000-20078-CT-TIP, 2004
7.
go back to reference Cohnen M, Poll LJ, Puettmann C, Ewen K, Saleh A, Modder U: Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153, 2003PubMed Cohnen M, Poll LJ, Puettmann C, Ewen K, Saleh A, Modder U: Effective doses in standard protocols for multi-slice CT scanning. Eur Radiol 13:1148–1153, 2003PubMed
8.
go back to reference International Commission on Radiological Protection: The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann. ICRP 37, 1–332, 2007 International Commission on Radiological Protection: The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann. ICRP 37, 1–332, 2007
9.
go back to reference Rusinek H, Naidich DP, McGuinness G, Leitman BS, McCauley DI, Krinsky GA, Clayton K, Cohen H: Pulmonary nodule detection: low-dose versus conventional CT. Radiology 209:243–249, 1998PubMed Rusinek H, Naidich DP, McGuinness G, Leitman BS, McCauley DI, Krinsky GA, Clayton K, Cohen H: Pulmonary nodule detection: low-dose versus conventional CT. Radiology 209:243–249, 1998PubMed
10.
go back to reference Hoe CL, Samei E, Frush DP, Delong DM: Simulation of liver lesions for pediatric CT. Radiology 238:699–705, 2006PubMedCrossRef Hoe CL, Samei E, Frush DP, Delong DM: Simulation of liver lesions for pediatric CT. Radiology 238:699–705, 2006PubMedCrossRef
11.
go back to reference Li X, Samei E, Delong DM, Jones RP, Gaca AM, Hollingsworth CL, Maxfield CM, Carrico CW, Frush DP: Three-dimensional simulation of lung nodules for paediatric multidetector array CT. Br J Radiol 82:401–411, 2009PubMedCrossRef Li X, Samei E, Delong DM, Jones RP, Gaca AM, Hollingsworth CL, Maxfield CM, Carrico CW, Frush DP: Three-dimensional simulation of lung nodules for paediatric multidetector array CT. Br J Radiol 82:401–411, 2009PubMedCrossRef
12.
go back to reference Starr SJ, Metz CE, Lusted LB, Goodenough DJ: Visual detection and localization of radiographic images. Radiology 116:533–538, 1975PubMed Starr SJ, Metz CE, Lusted LB, Goodenough DJ: Visual detection and localization of radiographic images. Radiology 116:533–538, 1975PubMed
13.
go back to reference Schwartz LH, Gandras EJ, Colangelo SM, Ercolani MC, Panicek DM: Prevalence and importance of small hepatic lesions found at CT in patients with cancer. Radiology 210:71–74, 1999PubMedCrossRef Schwartz LH, Gandras EJ, Colangelo SM, Ercolani MC, Panicek DM: Prevalence and importance of small hepatic lesions found at CT in patients with cancer. Radiology 210:71–74, 1999PubMedCrossRef
14.
go back to reference Robinson PJ, Arnold P, Wilson D: Small “indeterminate” lesions on CT of the liver: a follow-up study of stability. Br J Radiol 76:866–874, 2003PubMedCrossRef Robinson PJ, Arnold P, Wilson D: Small “indeterminate” lesions on CT of the liver: a follow-up study of stability. Br J Radiol 76:866–874, 2003PubMedCrossRef
15.
go back to reference Winterer JT, Kotter E, Ghanem N, Langer M: Detection and characterization of benign focal liver lesions with multislice CT. Eur Radiol 16:2427–2443, 2006PubMedCrossRef Winterer JT, Kotter E, Ghanem N, Langer M: Detection and characterization of benign focal liver lesions with multislice CT. Eur Radiol 16:2427–2443, 2006PubMedCrossRef
16.
go back to reference Brennan PC, McEntee M, Evanoff M, Phillips P, O’Connor WT, Manning DJ: Ambient lighting: effect of illumination on soft-copy viewing of radiographs of the wrist. Am J Roentgenol 188:W177–W180, 2007CrossRef Brennan PC, McEntee M, Evanoff M, Phillips P, O’Connor WT, Manning DJ: Ambient lighting: effect of illumination on soft-copy viewing of radiographs of the wrist. Am J Roentgenol 188:W177–W180, 2007CrossRef
17.
go back to reference Hanai K, Horiuchi T, Sekiguchi J, Muramatsu Y, Kakinuma R, Moriyama N, Tuchiiya R, Niki N: Computer-simulation technique for low dose computed tomographic screening. J Comput Assist Tomogr 30:955–961, 2006PubMedCrossRef Hanai K, Horiuchi T, Sekiguchi J, Muramatsu Y, Kakinuma R, Moriyama N, Tuchiiya R, Niki N: Computer-simulation technique for low dose computed tomographic screening. J Comput Assist Tomogr 30:955–961, 2006PubMedCrossRef
18.
go back to reference Tuddenham WJ: Visual search, image organization, and reader error in roentgen diagnosis. Studies of the psycho-physiology of Roentgen image perception. Radiology 78:694–704, 1962PubMed Tuddenham WJ: Visual search, image organization, and reader error in roentgen diagnosis. Studies of the psycho-physiology of Roentgen image perception. Radiology 78:694–704, 1962PubMed
19.
go back to reference Donovan T, Manning DJ: The radiology task: Bayesian theory and perception. Br J Radiol 80:389–391, 2007PubMedCrossRef Donovan T, Manning DJ: The radiology task: Bayesian theory and perception. Br J Radiol 80:389–391, 2007PubMedCrossRef
20.
go back to reference Jones EC, Chezmar JL, Nelson RC, Bernardino ME: The frequency and significance of small (less than or equal to 15 mm) hepatic lesions detected by CT. Am J Roentgenol 158:535–539, 1992CrossRef Jones EC, Chezmar JL, Nelson RC, Bernardino ME: The frequency and significance of small (less than or equal to 15 mm) hepatic lesions detected by CT. Am J Roentgenol 158:535–539, 1992CrossRef
21.
go back to reference Kinchla RA, Chen Z, Evert D: Precue effects in visual search: data or resource limited? Percept Psychophys 57:441–450, 1995PubMedCrossRef Kinchla RA, Chen Z, Evert D: Precue effects in visual search: data or resource limited? Percept Psychophys 57:441–450, 1995PubMedCrossRef
22.
23.
go back to reference Kundel HL, Nodine CF, Carmody D: Visual scanning, pattern recognition and decision-making in pulmonary nodule detection. Invest Radiol 13:175–181, 1978PubMedCrossRef Kundel HL, Nodine CF, Carmody D: Visual scanning, pattern recognition and decision-making in pulmonary nodule detection. Invest Radiol 13:175–181, 1978PubMedCrossRef
24.
go back to reference Baron RL: Understanding and optimizing use of contrast material for CT of the liver. Am J Roentgenol 163:323–331, 1994CrossRef Baron RL: Understanding and optimizing use of contrast material for CT of the liver. Am J Roentgenol 163:323–331, 1994CrossRef
25.
go back to reference Foley WD, Berland LL, Lawson TL, Smith DF, Thorsen MK: Contrast enhancement technique for dynamic hepatic computed tomographic scanning. Radiology 147:797–803, 1983PubMed Foley WD, Berland LL, Lawson TL, Smith DF, Thorsen MK: Contrast enhancement technique for dynamic hepatic computed tomographic scanning. Radiology 147:797–803, 1983PubMed
Metadata
Title
Optimization of Computed Tomography Protocols: Limitations of a Methodology Employing a Phantom with Location-Known Opacities
Authors
Karen L. Dobeli
Sarah J. Lewis
Steven R. Meikle
David L. Thiele
Patrick C. Brennan
Publication date
01-12-2013
Publisher
Springer US
Published in
Journal of Imaging Informatics in Medicine / Issue 6/2013
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-013-9595-6

Other articles of this Issue 6/2013

Journal of Digital Imaging 6/2013 Go to the issue