Skip to main content
Top
Published in: European Journal of Nuclear Medicine and Molecular Imaging 11/2003

01-11-2003 | Original Article

Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study

Authors: Fabrice Gutman, Isabelle Gardin, Nicolas Delahaye, Hervé Rakotonirina, Anne Hitzel, Alain Manrique, Dominique Le Guludec, Pierre Véra

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 11/2003

Login to get access

Abstract

Iterative reconstruction algorithms, such as the ordered subsets expectation maximisation (OS-EM), are a promising alternative to filtered backprojection (FBP). The aims of this study were first to optimise the OS-EM algorithm in terms of iteration number and to study the usefulness of post-filtering, and second to compare OS-EM and FBP for image reconstruction on a fluorine-18 fluorodeoxyglucose (18F-FDG) dual-head camera (DHC). These two goals were addressed using phantom acquisitions. The performances of these algorithms were also studied in patient acquisitions performed on a DHC and a PET on the same day. Phantom experiments were performed on a DHC using a Jaszczak phantom containing six spheres filled with 18F-FDG, two background levels (0.95, 6.80 kBq/ml) and three object contrasts (5.9, 3.7, 2.7). The reconstruction algorithms were FBP with a Gaussian filter (FWHM 0.5–2 pixel width) and OS-EM using 8–128 equivalent iterations (equivalent to the ML-EM algorithm) with and without Gaussian post-filtering [OS-EM (iterations, pixel width)]. Contrast recovery coefficient (CRC) and noise characteristics were assessed. Twenty-two patients (21 male, one female; age 55±15 years) with lung cancer underwent, on the same day, PET (1 h post injection of 37 MBq/kg 18F-FDG) and DHC acquisitions (3 h post injection). DHC data were reconstructed using six methods: FBP (1), OS-EM (16), (40), (40,1), (64) and (64,1). These sets were evaluated by two observers and compared to PET reconstructed with OS-EM (16). The number of detected lesions and the visual quality were assessed. A marked improvement in CRC was observed with OS-EM as compared with FBP when more than 24 iterations were used. The CRC increased markedly from 8 to 40 iterations and then reached a plateau. The noise was stable until 40 iterations and then increased. The best compromise was obtained for OS-EM (32) and OS-EM (40,1). For the patient study, OS-EM provided images of better visual quality, but with no significant difference in detection sensitivity. OS-EM was superior to FBP in terms of contrast recovery and noise level. The optimal compromise between contrast recovery and noise was obtained for OS-EM (32) and (40,1) on the phantom study. The clinical study showed that OS-EM yielded images of better visual quality but with no improvement in terms of detection of lung cancer.
Literature
1.
go back to reference Ak I, Stokkel MP, Pauwels EK. Positron emission tomography with 2-[18F]fluoro-2-deoxy-d-glucose in oncology. Part II. The clinical value in detecting and staging primary tumours. J Cancer Res Clin Oncol 2000; 126:560–574.PubMed Ak I, Stokkel MP, Pauwels EK. Positron emission tomography with 2-[18F]fluoro-2-deoxy-d-glucose in oncology. Part II. The clinical value in detecting and staging primary tumours. J Cancer Res Clin Oncol 2000; 126:560–574.PubMed
2.
go back to reference Ak I, Blokland JA, Pauwels EK, Stokkel MP. The clinical value of18F-FDG detection with a dual-head coincidence camera: a review. Eur J Nucl Med 2001; 28:763–778.CrossRefPubMed Ak I, Blokland JA, Pauwels EK, Stokkel MP. The clinical value of18F-FDG detection with a dual-head coincidence camera: a review. Eur J Nucl Med 2001; 28:763–778.CrossRefPubMed
3.
go back to reference Bomanji JB, Costa DC, Ell PJ. Clinical role of positron emission tomography in oncology. Lancet Oncol 2001; 2:157–164.PubMed Bomanji JB, Costa DC, Ell PJ. Clinical role of positron emission tomography in oncology. Lancet Oncol 2001; 2:157–164.PubMed
4.
go back to reference Meikle SR, Hutton BF, Bailey DL, Hooper PK, Fulham MJ. Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability. Phys Med Biol 1994; 39:1689–1704.CrossRef Meikle SR, Hutton BF, Bailey DL, Hooper PK, Fulham MJ. Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability. Phys Med Biol 1994; 39:1689–1704.CrossRef
5.
go back to reference Liow JS, Strother SC. Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions. IEEE Trans Med Imaging 1991; 10:563–570.CrossRef Liow JS, Strother SC. Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions. IEEE Trans Med Imaging 1991; 10:563–570.CrossRef
6.
go back to reference Liow JS, Strother SC. The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction. Phys Med Biol 1993; 38:55–70.CrossRefPubMed Liow JS, Strother SC. The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction. Phys Med Biol 1993; 38:55–70.CrossRefPubMed
7.
go back to reference Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994; 13:601–609.CrossRef Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994; 13:601–609.CrossRef
8.
go back to reference Beekman FJ, Slijpen ET, Niessen WJ. Selection of task-dependent diffusion filters for the post-processing of SPECT images. Phys Med Biol 1998; 43:1713–1730. Beekman FJ, Slijpen ET, Niessen WJ. Selection of task-dependent diffusion filters for the post-processing of SPECT images. Phys Med Biol 1998; 43:1713–1730.
9.
go back to reference Tiling R, Tatsch K, Sommer H, Meyer G. Technetium-99m-sestamibi scintimammography for the detection of breast carcinoma: comparison between planar and SPECT imaging. J Nucl Med 1998; 39:849–856.PubMed Tiling R, Tatsch K, Sommer H, Meyer G. Technetium-99m-sestamibi scintimammography for the detection of breast carcinoma: comparison between planar and SPECT imaging. J Nucl Med 1998; 39:849–856.PubMed
10.
go back to reference Blocklet D, Seret A, Popa N, Schoutens A. Maximum-likelihood reconstruction with ordered subsets in bone SPECT. J Nucl Med 1999; 40:1978–1984.PubMed Blocklet D, Seret A, Popa N, Schoutens A. Maximum-likelihood reconstruction with ordered subsets in bone SPECT. J Nucl Med 1999; 40:1978–1984.PubMed
11.
go back to reference Moka D, Eschner W, Voth E, Dietlein M, Larena-Avellaneda A, Schicha H. Iterative reconstruction: an improvement of technetium-99m MIBI SPET for the detection of parathyroid adenomas? Eur J Nucl Med 2000; 27:485–489.PubMed Moka D, Eschner W, Voth E, Dietlein M, Larena-Avellaneda A, Schicha H. Iterative reconstruction: an improvement of technetium-99m MIBI SPET for the detection of parathyroid adenomas? Eur J Nucl Med 2000; 27:485–489.PubMed
12.
go back to reference Zasadny KR, Wahl RL. Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-d-glucose: variations with body weight and a method for correction. Radiology 1993; 189:847–850.PubMed Zasadny KR, Wahl RL. Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-d-glucose: variations with body weight and a method for correction. Radiology 1993; 189:847–850.PubMed
13.
go back to reference Brix G, Zaers J, Adam LE, et al. Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers' Association. J Nucl Med 1997; 38:1614–1623.PubMed Brix G, Zaers J, Adam LE, et al. Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers' Association. J Nucl Med 1997; 38:1614–1623.PubMed
14.
go back to reference Martin WH, Delbeke D, Patton JA, Sandler MP. Detection of malignancies with SPECT versus PET, with 2-[fluorine-18]fluoro-2-deoxy-d-glucose. Radiology 1996; 198:225–231.PubMed Martin WH, Delbeke D, Patton JA, Sandler MP. Detection of malignancies with SPECT versus PET, with 2-[fluorine-18]fluoro-2-deoxy-d-glucose. Radiology 1996; 198:225–231.PubMed
15.
go back to reference Wahl RL, Cody RL, Hutchins GD, Mudgett EE. Primary and metastatic breast carcinoma: initial clinical evaluation with PET with the radiolabeled glucose analogue 2-[F-18]-fluoro-2-deoxy-d-glucose. Radiology 1991; 179:765–770.PubMed Wahl RL, Cody RL, Hutchins GD, Mudgett EE. Primary and metastatic breast carcinoma: initial clinical evaluation with PET with the radiolabeled glucose analogue 2-[F-18]-fluoro-2-deoxy-d-glucose. Radiology 1991; 179:765–770.PubMed
16.
go back to reference Muehllehner G, Buchin M, Dudek J. Performance parameters of a positron imaging camera. IEEE Trans Nucl Sci 1976; NS-23:528–537. Muehllehner G, Buchin M, Dudek J. Performance parameters of a positron imaging camera. IEEE Trans Nucl Sci 1976; NS-23:528–537.
17.
go back to reference Snyder DL, Miller MI, Thomas LJ, Politte DG. Noise and edge artifacts in maximum-likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1987; 6:228–238. Snyder DL, Miller MI, Thomas LJ, Politte DG. Noise and edge artifacts in maximum-likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1987; 6:228–238.
18.
go back to reference Wallis JW, Miller TR. Rapidly converging iterative reconstruction algorithms in single-photon emission computed tomography. J Nucl Med 1993; 34:1793–1800.PubMed Wallis JW, Miller TR. Rapidly converging iterative reconstruction algorithms in single-photon emission computed tomography. J Nucl Med 1993; 34:1793–1800.PubMed
19.
go back to reference Kadrmas DJ, Christian PE. Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis. J Nucl Med 2002; 43:1545–1554. Kadrmas DJ, Christian PE. Comparative evaluation of lesion detectability for 6 PET imaging platforms using a highly reproducible whole-body phantom with (22)Na lesions and localization ROC analysis. J Nucl Med 2002; 43:1545–1554.
20.
go back to reference Farquhar TH, Llacer J, Sayre J, Tai YC, Hoffman EJ. ROC and LROC analyses of the effects of lesion contrast, size, and signal-to-noise ratio on detectability in PET images. J Nucl Med 2000; 41:745–754.PubMed Farquhar TH, Llacer J, Sayre J, Tai YC, Hoffman EJ. ROC and LROC analyses of the effects of lesion contrast, size, and signal-to-noise ratio on detectability in PET images. J Nucl Med 2000; 41:745–754.PubMed
21.
go back to reference Farquhar TH, Llacer J, Hoh CK, et al. ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm. J Nucl Med 1999; 40:2043–2052.PubMed Farquhar TH, Llacer J, Hoh CK, et al. ROC and localization ROC analyses of lesion detection in whole-body FDG PET: effects of acquisition mode, attenuation correction and reconstruction algorithm. J Nucl Med 1999; 40:2043–2052.PubMed
22.
go back to reference Ramos CD, Erdi YE, Gonen M, et al. FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection. Eur J Nucl Med 2001; 28:155–164.CrossRefPubMed Ramos CD, Erdi YE, Gonen M, et al. FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection. Eur J Nucl Med 2001; 28:155–164.CrossRefPubMed
23.
go back to reference Paul AK, Tatsumi M, Yutani K, Fujino K, Hashikawa K, Nishimura T. Effects of iterative reconstruction on image contrast and lesion detection in gamma camera coincidence imaging in lung and breast cancers. Nucl Med Commun 2002; 23:103–110.CrossRefPubMed Paul AK, Tatsumi M, Yutani K, Fujino K, Hashikawa K, Nishimura T. Effects of iterative reconstruction on image contrast and lesion detection in gamma camera coincidence imaging in lung and breast cancers. Nucl Med Commun 2002; 23:103–110.CrossRefPubMed
Metadata
Title
Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study
Authors
Fabrice Gutman
Isabelle Gardin
Nicolas Delahaye
Hervé Rakotonirina
Anne Hitzel
Alain Manrique
Dominique Le Guludec
Pierre Véra
Publication date
01-11-2003
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 11/2003
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-003-1246-6

Other articles of this Issue 11/2003

European Journal of Nuclear Medicine and Molecular Imaging 11/2003 Go to the issue

Letter to the Editor

Reply