Abstract

Background

The primary experience of open triple-branched stent graft placement for acute aortic arch dissection was reported.

Methods

Between January 2011 and October 2011, 13 well-selected patients (mea age, 46±8.2 years; approximate range, 30~58 years) with acute aortic arch dissection underwent open triple-branched stent graft placement for total arch reconstruction. The triple-branched stent graft was a branched 1-piece graft consisting of a self-expandable nitinol stent and polyester vascular graft fabric (Yuhengjia Sci Tech Corp Ltd, Beijing, China).During hypothermic circulatory arrest, through the transverse incision of the ascending aorta, the main graft of the triple-branched stent graft was inserted into the true lumen of the arch and proximal descending aorta, and then each sidearm graft was positioned one by one into the aortic branch. Once the main graft and sidearm grafts were properly positioned, the restraining strings were withdrawn and then the main graft and sidearm grafts were deployed. Enhanced electric beam computed tomography was performed in each patient before discharge to evaluate the postoperative time course of the residual false lumen.

Results

Open triple-branched stent graft placement was technically successful in all patients. The mean cardiopulmonary bypass time, aortic cross-clamp time and arrest time were 138.40±47.75 min, 70.60±28.94 min and 28.60±12.48 min, respectively. All patients were discharged from hospital. Their computed tomographic scans postoperatively showed that all stent grafts were fully opened and not kinked, there was no blood flow surrounding the triple-branched stent graft.

Conclusion

Open triple-branched stent graft placement is a new effective technique for total arch reconstruction in acute arch dissection.
Appendix
Available only for authorised users
Literature
1.
go back to reference Borst HG, Walterbusch G, Schaps D: Extensive aortic replacement using the “elephant trunk” prosthesis. Thorac Cardiovasc Surg. 1983, 31: 37-40. 10.1055/s-2007-1020290.CrossRefPubMed Borst HG, Walterbusch G, Schaps D: Extensive aortic replacement using the “elephant trunk” prosthesis. Thorac Cardiovasc Surg. 1983, 31: 37-40. 10.1055/s-2007-1020290.CrossRefPubMed
2.
go back to reference Heinemann MK, Buehner B, Jurmann MJ, Borst HG: Use of the “elephant trunk technique” in aortic surgery. Ann Thorac Surg. 1995, 60: 2-7.CrossRefPubMed Heinemann MK, Buehner B, Jurmann MJ, Borst HG: Use of the “elephant trunk technique” in aortic surgery. Ann Thorac Surg. 1995, 60: 2-7.CrossRefPubMed
3.
go back to reference Svensson LG: Rationale and technique for replacement of the ascending aorta, arch, and distal aorta using a modified elephant trunk procedure. J Card Surg. 1992, 7: 301-321. 10.1111/j.1540-8191.1992.tb01020.x.CrossRefPubMed Svensson LG: Rationale and technique for replacement of the ascending aorta, arch, and distal aorta using a modified elephant trunk procedure. J Card Surg. 1992, 7: 301-321. 10.1111/j.1540-8191.1992.tb01020.x.CrossRefPubMed
4.
go back to reference Crawford ES, Coselli JS, Svensson LG, Safi HJ, Hess KR: Diffuse aneurysmal disease (chronic aortic dissection, Marfan, and mega aorta syndromes) and multiple aneurysm: treatment by subtotal and total aortic replacement emphasizing the elephant trunk operation. Ann Surg. 1990, 211: 521-537. 10.1097/00000658-199005000-00002.CrossRefPubMedPubMedCentral Crawford ES, Coselli JS, Svensson LG, Safi HJ, Hess KR: Diffuse aneurysmal disease (chronic aortic dissection, Marfan, and mega aorta syndromes) and multiple aneurysm: treatment by subtotal and total aortic replacement emphasizing the elephant trunk operation. Ann Surg. 1990, 211: 521-537. 10.1097/00000658-199005000-00002.CrossRefPubMedPubMedCentral
5.
go back to reference Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, Matsuda H: New graft-implanting method for thoracic aortic aneurysm or dissectionwith a stented graft. Circulation. 1996, 94 (suppl II): II188-II193.PubMed Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, Matsuda H: New graft-implanting method for thoracic aortic aneurysm or dissectionwith a stented graft. Circulation. 1996, 94 (suppl II): II188-II193.PubMed
6.
go back to reference Liu ZG, Sun LZ, Chang Q, Zhu JM, Dong C, Yu CT, Liu YM, Zhang HT: Should the “elephant trunk” be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection. J Thorac Cardiovasc Surg. 2006, 131: 107-113. 10.1016/j.jtcvs.2005.09.015.CrossRefPubMed Liu ZG, Sun LZ, Chang Q, Zhu JM, Dong C, Yu CT, Liu YM, Zhang HT: Should the “elephant trunk” be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection. J Thorac Cardiovasc Surg. 2006, 131: 107-113. 10.1016/j.jtcvs.2005.09.015.CrossRefPubMed
7.
go back to reference Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K: The results of total arch graft implantation with open stent graft placement for type A aortic dissection. J Thorac Cardiovasc Surg. 2002, 124: 531-540. 10.1067/mtc.2002.124388.CrossRefPubMed Kato M, Kuratani T, Kaneko M, Kyo S, Ohnishi K: The results of total arch graft implantation with open stent graft placement for type A aortic dissection. J Thorac Cardiovasc Surg. 2002, 124: 531-540. 10.1067/mtc.2002.124388.CrossRefPubMed
8.
go back to reference Ishihara H, Uchida N, Yamasaki C, Sakashita M, Kanou M: Extensive primary repair of the thoracic aorta in Stanford type A acute aortic dissection by means of a synthetic vascular graft with a self-expandable stent. J Thorac Cardiovasc Surg. 2002, 123: 1035-1040. 10.1067/mtc.2002.120729.CrossRefPubMed Ishihara H, Uchida N, Yamasaki C, Sakashita M, Kanou M: Extensive primary repair of the thoracic aorta in Stanford type A acute aortic dissection by means of a synthetic vascular graft with a self-expandable stent. J Thorac Cardiovasc Surg. 2002, 123: 1035-1040. 10.1067/mtc.2002.120729.CrossRefPubMed
9.
go back to reference Shimamura K, Kuratani T, Matsumiya G, Kato M, Shirakawa Y, Takano H, Ohta N, Sawa Y: Long-term results of the open stent-grafting technique for extended aortic arch disease. J Thorac Cardiovasc Surg. 2008, 135: 1261-1269. 10.1016/j.jtcvs.2007.10.056.CrossRefPubMed Shimamura K, Kuratani T, Matsumiya G, Kato M, Shirakawa Y, Takano H, Ohta N, Sawa Y: Long-term results of the open stent-grafting technique for extended aortic arch disease. J Thorac Cardiovasc Surg. 2008, 135: 1261-1269. 10.1016/j.jtcvs.2007.10.056.CrossRefPubMed
10.
go back to reference Shimamura K, Kuratani T, Matsumiya G, Shirakawa Y, Takeuchi M, Takano H, Sawa : Hybrid endovascular aortic arch repair using branched endoprosthesis: the second-generation “branched” open stent-grafting technique. J Thorac Cardiovasc Surg. 2009, 138: 46-53. 10.1016/j.jtcvs.2009.03.025.CrossRefPubMed Shimamura K, Kuratani T, Matsumiya G, Shirakawa Y, Takeuchi M, Takano H, Sawa : Hybrid endovascular aortic arch repair using branched endoprosthesis: the second-generation “branched” open stent-grafting technique. J Thorac Cardiovasc Surg. 2009, 138: 46-53. 10.1016/j.jtcvs.2009.03.025.CrossRefPubMed
11.
go back to reference Chen LW, Dai XF, Lu L, Zhang GC, Cao H: Extensive primary repair of the thoracic aorta in acute type A aortic dissection by means of ascending aorta replacement combined with open placement of triple-branched stent graft early results. Circulation. 2010, 122: 1373-1378. 10.1161/CIRCULATIONAHA.110.946012.CrossRefPubMed Chen LW, Dai XF, Lu L, Zhang GC, Cao H: Extensive primary repair of the thoracic aorta in acute type A aortic dissection by means of ascending aorta replacement combined with open placement of triple-branched stent graft early results. Circulation. 2010, 122: 1373-1378. 10.1161/CIRCULATIONAHA.110.946012.CrossRefPubMed
12.
go back to reference Hirotani T, Kameda T, Kumamoto T, Shirota S, Yamano M: Protective effect of thiopental against cerebral ischemia during circulatory arrest. Thorac Cardiovasc Surg. 1999, 47: 223-228. 10.1055/s-2007-1013148.CrossRefPubMed Hirotani T, Kameda T, Kumamoto T, Shirota S, Yamano M: Protective effect of thiopental against cerebral ischemia during circulatory arrest. Thorac Cardiovasc Surg. 1999, 47: 223-228. 10.1055/s-2007-1013148.CrossRefPubMed
13.
go back to reference Kato M, Matsuda T, Kaneko M, Kuratani T, Mizushima T, Seo Y, Uchida H, Kichikawa K, Maeda M, Ohnishi K: Outcomes of stent-graft treatment of false lumen in aortic dissection. Circulation. 1998, 98 (suppl II): 305-312. Kato M, Matsuda T, Kaneko M, Kuratani T, Mizushima T, Seo Y, Uchida H, Kichikawa K, Maeda M, Ohnishi K: Outcomes of stent-graft treatment of false lumen in aortic dissection. Circulation. 1998, 98 (suppl II): 305-312.
14.
go back to reference Shen K, Tang H, Jing R, Liu F, Zhou : Application of triple-branched stent graft for Stanford type A aortic dissection: potential risks. Eur J Cardiothorac Surg. 2012, 41: e12-e17. 10.1093/ejcts/ezr259.CrossRefPubMed Shen K, Tang H, Jing R, Liu F, Zhou : Application of triple-branched stent graft for Stanford type A aortic dissection: potential risks. Eur J Cardiothorac Surg. 2012, 41: e12-e17. 10.1093/ejcts/ezr259.CrossRefPubMed
Metadata
Title
Open triple-branched stent graft placement for the surgical treatment of acute aortic arch dissection
Authors
Xiaoning Sun
Shuyang Lu
Shouguo Yang
Hao Lai
Hao Chen
Tao Hong
Chunsheng Wang
Publication date
01-12-2012
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2012
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/1749-8090-7-130

Other articles of this Issue 1/2012

Journal of Cardiothoracic Surgery 1/2012 Go to the issue