Published in: Journal of Anesthesia 5/2012

01-10-2012 | Original Article

One-lung ventilation in infants and small children: blood gas values

Authors: Christopher J. Sutton, Ayman Naguib, Suvikram Puri, Collin J. Sprenker, Enrico M. Camporesi

Published in: Journal of Anesthesia | Issue 5/2012

Login to get access

Abstract

Purpose

We investigated one-lung ventilation (OLV) in pediatric patients under 10 kg. The feasibility of OLV using either Arndt endobronchial blocker (AEB) or mainstem intubation technique is analyzed. Arterial blood gases (ABG) monitored throughout the procedures are presented.

Methods

Following IRB approval, a retrospective chart review was conducted on 9 patients ≤6 months of age and 2 patients ≥12 months of age undergoing lung resections or aortic coarctations. For right thoracotomy, a conventional, cuffed, endotracheal tube (ETT) was inserted and guided into the left mainstem bronchus with a bronchoscope and the left lung was ventilated. For left thoracotomy, an AEB was inserted into the trachea 2 cm past the vocal cords and an ETT was placed through the cords adjacent to the blockers (extraluminal). A bronchoscope was then inserted through the ETT to visualize and manipulate the blocker into the left mainstem bronchus. The blocker cuff was inflated slowly under direct vision while the ETT continued to ventilate the right, dependent lung. ABG values were collected intraoperatively in all cases.

Results

One-lung ventilation could be accomplished within 15 min in all cases, and lung isolation was successful in all patients. All patients were extubated within 12 h of surgery and had an uneventful recovery. ABG values revealed modest arterial acidosis and hypercarbia and mild acute ventilatory insufficiency.

Conclusion

The use of extraluminal AEB or mainstem intubation for OLV can be successfully completed in infants weighing less than 10 kg. OLV may induce acute respiratory pathology; therefore we recommend routine intraoperative ABG monitoring for pediatric patients.
Literature
1.
go back to reference Almeida-Junior AA, da Silva MT, Almeida CC, Ribeiro JD. Relationship between physiologic deadspace/tidal volume ratio and gas exchange in infants with acute bronchiolitis on invasive mechanical ventilation. Pediatr Crit Care Med. 2007;8(4):372–7.PubMedCrossRef Almeida-Junior AA, da Silva MT, Almeida CC, Ribeiro JD. Relationship between physiologic deadspace/tidal volume ratio and gas exchange in infants with acute bronchiolitis on invasive mechanical ventilation. Pediatr Crit Care Med. 2007;8(4):372–7.PubMedCrossRef
2.
go back to reference Hammer GB, Fitzmaurice BG, Brodsky JB. Methods for single-lung ventilation in pediatric patients. Anesth Analg. 1999;89(6):1426–9.PubMed Hammer GB, Fitzmaurice BG, Brodsky JB. Methods for single-lung ventilation in pediatric patients. Anesth Analg. 1999;89(6):1426–9.PubMed
3.
go back to reference Hammer GB, Brodsky JB, Redpath JH, Cannon WB. The Univent tube for single-lung ventilation in paediatric patients. Paediatr Anesth. 1998;8(1):55–7.CrossRef Hammer GB, Brodsky JB, Redpath JH, Cannon WB. The Univent tube for single-lung ventilation in paediatric patients. Paediatr Anesth. 1998;8(1):55–7.CrossRef
5.
6.
go back to reference Yun ES, Saulys A, Popic PM, Arndt GA. Single-lung ventilation in a pediatric patient using a pediatric fibreoptically-directed wire-guided endobronchial blocker. Can J Anaesth. 2002;49:256–61.PubMedCrossRef Yun ES, Saulys A, Popic PM, Arndt GA. Single-lung ventilation in a pediatric patient using a pediatric fibreoptically-directed wire-guided endobronchial blocker. Can J Anaesth. 2002;49:256–61.PubMedCrossRef
7.
go back to reference Use T, Shimamoto H, Fukano T, Sumikawa K. Single lung ventilation in a pediatric patient using a Fogarty catheter with a hollow center. Masui. 2004;53(1):69–71.PubMed Use T, Shimamoto H, Fukano T, Sumikawa K. Single lung ventilation in a pediatric patient using a Fogarty catheter with a hollow center. Masui. 2004;53(1):69–71.PubMed
8.
go back to reference Lew YS. Paediatric one lung anesthesia by selective bronchial intubation. Singapore Med J. 2000;41(8):398–400.PubMed Lew YS. Paediatric one lung anesthesia by selective bronchial intubation. Singapore Med J. 2000;41(8):398–400.PubMed
9.
go back to reference Schmidt C, Rellensmann G, Aken HV, Semik M, Bruessel T, Enk D. Single lung ventilation for pulmonary lobe resection in a newborn. Anesth Analg. 2005;101:362–4.PubMedCrossRef Schmidt C, Rellensmann G, Aken HV, Semik M, Bruessel T, Enk D. Single lung ventilation for pulmonary lobe resection in a newborn. Anesth Analg. 2005;101:362–4.PubMedCrossRef
10.
go back to reference Stephenson LL, Seefelder C. Routine extraluminal use of the 5F Arndt endobronchial blocker for one-lung ventilation in children up to 24 months of age. J Cardiothorac Vasc Anesth. 2011;25(4):683–6.PubMedCrossRef Stephenson LL, Seefelder C. Routine extraluminal use of the 5F Arndt endobronchial blocker for one-lung ventilation in children up to 24 months of age. J Cardiothorac Vasc Anesth. 2011;25(4):683–6.PubMedCrossRef
11.
go back to reference Wald SH, Mahajan A, Kaplan MB, Atkinson JB. Experience with the Arndt paediatric bronchial blocker. Br J Anaesthes. 2005;94(1):92–4.CrossRef Wald SH, Mahajan A, Kaplan MB, Atkinson JB. Experience with the Arndt paediatric bronchial blocker. Br J Anaesthes. 2005;94(1):92–4.CrossRef
Metadata
Title
One-lung ventilation in infants and small children: blood gas values
Authors
Christopher J. Sutton
Ayman Naguib
Suvikram Puri
Collin J. Sprenker
Enrico M. Camporesi
Publication date
01-10-2012
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 5/2012
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-012-1413-7

Other articles of this Issue 5/2012

Journal of Anesthesia 5/2012 Go to the issue