Skip to main content
Top
Published in: BMC Surgery 1/2022

Open Access 01-12-2022 | Research article

Novel multifunctional robotically assisted bipolar instrument for simultaneous radiofrequency sealing and transection: preclinical and single-center experience

Authors: Cristina Ibanez Jimenez, Adrit Lath, Forrest Ringold

Published in: BMC Surgery | Issue 1/2022

Login to get access

Abstract

Background

A novel robotic-assisted bipolar radiofrequency (RF) multifunctional vessel seal-and-transection instrument (SynchroSeal, Intuitive Surgical, Inc., Sunnyvale, CA) has been developed. The objective of the current paper is to describe the design of SynchroSeal based on bench studies, assess the safety of SynchroSeal in ex vivo and in vivo porcine studies, and provide early clinical context.

Methods

SynchroSeal grasping, energy activation time, and jaw temperature were evaluated with those of the Harmonic Ace+7. Data were analyzed with descriptive statistics, with Mann–Whitney for comparisons and statistical significance < 0.05. Ex vivo and in vivo animal safety assessments of tissue after SynchroSeal use were evaluated for burst pressure, thermal spread, and acute sealing. Last, a single-center analysis of the technical metrics of SynchroSeal and Vessel Sealer Extend (robotically assisted seal-and-transection instrument) in bariatric cases is provided.

Results

Bench studies of SynchroSeal and Harmonic Ace+7 evidenced SynchroSeal’s greater slip resistance force (8.4 ± 1.0 vs. 3.1 ± 0.4 N; p = 0.0002), lower grip pressure (3.0 ± 0.2 vs. 4.2 ± 0.5 kg/cm2; p = 0.0002), faster seal time (1.5 ± 0.4 vs. 11.6 ± 2.5 s; < 0.0001), lower mean jaw temperature (109.7 ± 7.2 vs. 247.4 ± 8.6 °C; p = 0.0051), and faster cooling to 40 °C (53.6 ± 2.1 vs. 68.0 ± 3.5 s; p = 0.0051). SynchroSeal’s mean burst pressures after seal-and-transection and seal only modes were, respectively, 1169.1 ± 393.1 mmHg and 1159.2 ± 454.6 mmHg. Mean thermal spreads were, respectively, 1.2 ± 0.6 mm and 1.5 ± 0.55 mm. In the chronic animal study, 102 vessels were sealed; at 3 weeks post-procedure, there was no evidence of leakage or adverse events, such as non-target tissue thermal spread or tissue damage. In bariatrics cases, SynchroSeal was activated more frequently per case; however, its mean activation time was significantly shorter than Vessel Sealer Extend. No adverse events were reported for either device.

Conclusions

SynchroSeal’s multifunctional design provides enhanced sealing and transection capabilities with an acceptable safety profile.
Literature
1.
go back to reference Buysse Steven P, Orszulak James H, Wham Robert H. Vessel sealing system. U.S. Patent No. 6,398,779. 4 Jun. 2002. Buysse Steven P, Orszulak James H, Wham Robert H. Vessel sealing system. U.S. Patent No. 6,398,779. 4 Jun. 2002.
5.
7.
go back to reference Shah JM, Hemphill JW, Lundstrom FR, Marion DW. Patent Number: 20210093369 “Simultaneous electrosurgical sealing and cutting” Intuitive Surgical Operations, Inc., Sunnyvale, CA, USA. Shah JM, Hemphill JW, Lundstrom FR, Marion DW. Patent Number: 20210093369 “Simultaneous electrosurgical sealing and cutting” Intuitive Surgical Operations, Inc., Sunnyvale, CA, USA.
9.
go back to reference Kim FJ, Chammas MF Jr, Gewehr E, Morihisa M, Caldas F, Hayacibara E, Baptistussi M, Meyer F, Martins AC. Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc. 2008;22:1464–9.CrossRef Kim FJ, Chammas MF Jr, Gewehr E, Morihisa M, Caldas F, Hayacibara E, Baptistussi M, Meyer F, Martins AC. Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc. 2008;22:1464–9.CrossRef
10.
go back to reference Premarket Notification (510(k)) Submissions for Bipolar Electrosurgical Vessel Sealers for General Surgery, Guidance for Industry and Food and Drug Administration Staff, August 2016. Premarket Notification (510(k)) Submissions for Bipolar Electrosurgical Vessel Sealers for General Surgery, Guidance for Industry and Food and Drug Administration Staff, August 2016.
Metadata
Title
Novel multifunctional robotically assisted bipolar instrument for simultaneous radiofrequency sealing and transection: preclinical and single-center experience
Authors
Cristina Ibanez Jimenez
Adrit Lath
Forrest Ringold
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Surgery / Issue 1/2022
Electronic ISSN: 1471-2482
DOI
https://doi.org/10.1186/s12893-022-01483-5

Other articles of this Issue 1/2022

BMC Surgery 1/2022 Go to the issue