Excerpt

Sir: The use of standard devices to provide continuous positive airway pressure (CPAP) outside the intensive care unit (ICU) environment may be awkward in the absence of adequate facilities. Therefore, simplified respirators and transportable CPAP systems are employed. However, these devices are still bulky, due to the presence of ventilatory circuits and separate additional machines. …
Literature
1.
go back to reference Monchi M (1997) Comparison of the performance of 5 systems of spontaneous ventilation with CPAP on a mechanical lung. Thèse de Doctorat en Médecine, Université Paris VI, Paris, France Monchi M (1997) Comparison of the performance of 5 systems of spontaneous ventilation with CPAP on a mechanical lung. Thèse de Doctorat en Médecine, Université Paris VI, Paris, France
2.
go back to reference Maitre B, Jaber S, Maggiore SM, Bergot E, Richard JC, Bakthiari H, Housset B, Boussignac G, Brochard L (2000) Continuous positive airway pressure during fiberoptic bronchoscopy in hypoxemic patients. A randomized double-blind study using a new device. Am J Respir Crit Care Med 162:1063–1067PubMed Maitre B, Jaber S, Maggiore SM, Bergot E, Richard JC, Bakthiari H, Housset B, Boussignac G, Brochard L (2000) Continuous positive airway pressure during fiberoptic bronchoscopy in hypoxemic patients. A randomized double-blind study using a new device. Am J Respir Crit Care Med 162:1063–1067PubMed
3.
go back to reference Moritz F, Benichou J, Vanheste M, Richard JC, Line S, Hellot MF, Bonmarchand C, Muller JM (2003) Boussignac continuous positive airway pressure device in the emergency care of acute cardiogenic pulmonary oedema: a randomized pilot study. Eur J Emerg Med 10:204–208PubMedCrossRef Moritz F, Benichou J, Vanheste M, Richard JC, Line S, Hellot MF, Bonmarchand C, Muller JM (2003) Boussignac continuous positive airway pressure device in the emergency care of acute cardiogenic pulmonary oedema: a randomized pilot study. Eur J Emerg Med 10:204–208PubMedCrossRef
4.
go back to reference Leman P, Greene S, Whelan K, Legassick T (2005) Simple lightweight disposable continuous positive airways pressure mask to effectively treat acute pulmonary oedema: Randomized controlled trial. Emerg Med Australas 17:224–230PubMed Leman P, Greene S, Whelan K, Legassick T (2005) Simple lightweight disposable continuous positive airways pressure mask to effectively treat acute pulmonary oedema: Randomized controlled trial. Emerg Med Australas 17:224–230PubMed
5.
go back to reference Templier F, Dolveck F, Baer M, Chauvin M, Fletcher D (2003) “Boussignac” continuous positive airway pressure system: practical use in a prehospital medical care unit. Eur J Emerg Med 10:87–93PubMedCrossRef Templier F, Dolveck F, Baer M, Chauvin M, Fletcher D (2003) “Boussignac” continuous positive airway pressure system: practical use in a prehospital medical care unit. Eur J Emerg Med 10:87–93PubMedCrossRef
Metadata
Title
Novel indications for the Boussignac CPAP valve
Authors
Marco Cigada
Giovanluigi Elia
Michele Umbrello
Matteo Giacomini
Giovanni Mistraletti
Concezione Tommasino
Gaetano Iapichino
Publication date
01-02-2007
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 2/2007
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-006-0472-3

Other articles of this Issue 2/2007

Intensive Care Medicine 2/2007 Go to the issue

Announcements

Announcement