Abstract

Purpose

This study aims to evaluate the digitally designed ball attachment housing in its initial retentive force and after 2 years of simulated clinical use and to compare it with the regular nylon ball attachment housing.

Materials and methods

Twenty implants with their corresponding ball abutments (diameter 4.5 × 4.0 mm) were inserted in resin blocks. They were divided into two groups. In Group I, ten ball abutments each received their corresponding conventional attachment with nylon rings. In Group II, ten ball abutments received the novel CAD–CAM polyetheretherketone ball attachment housing. A universal testing machine was used to measure the retention force. The achieved maximum values of retention force were recorded at the beginning of the study (initial retention) and after 2 years of artificial ageing (2000 cycles of insertion and removal). Results were statistically analyzed using an independent sample T test.

Results

The PEEK attachment housing showed high retention forces (25.12 ± 0.99 N) compared to the conventional attachment with a nylon ring (15.76 ± 0.93 N) in the initial dislodgement test. There was a statistically significant difference in mean retention at the initial retention test and after 2 years of stimulated usage between the two studied groups, p = 0.000.

Conclusions

Within the limitations of this study, the novel CAD–CAM–PEEK attachment showed high retention characteristics compared to the conventional attachment with nylon rings, initially and after simulated long-term use.
Appendix
Available only for authorised users
Literature
1.
go back to reference Hakeem AA, Shah AS, Shazana QN, Bali KS. Evaluation of patient satisfaction in precision attachment-supported overdentures and conventional overdentures through verbal rating system. Int J Adv Res. 2021;9:963–7.CrossRef Hakeem AA, Shah AS, Shazana QN, Bali KS. Evaluation of patient satisfaction in precision attachment-supported overdentures and conventional overdentures through verbal rating system. Int J Adv Res. 2021;9:963–7.CrossRef
3.
go back to reference Abdelaziz MS, Fawzy AM, Ghali RM, Nassar HI. Retention of different attachment systems for digitally designed mandibular implant overdenture. J Prosthodont. 2023;32:162–9.CrossRefPubMed Abdelaziz MS, Fawzy AM, Ghali RM, Nassar HI. Retention of different attachment systems for digitally designed mandibular implant overdenture. J Prosthodont. 2023;32:162–9.CrossRefPubMed
6.
go back to reference Abdelaziz MS, Fawzy A, Ghali RMNH. Retention loss of locator attachment system different retention caps for two implant retained mandibular overdenture. Futur Dent J. 2022;7:120–6. Abdelaziz MS, Fawzy A, Ghali RMNH. Retention loss of locator attachment system different retention caps for two implant retained mandibular overdenture. Futur Dent J. 2022;7:120–6.
7.
go back to reference Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35:594–600.CrossRefPubMed Stock V, Wagner C, Merk S, Roos M, Schmidlin PR, et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35:594–600.CrossRefPubMed
8.
go back to reference Maryod WH, Taha ER, Alkaranfilly GA, El-anwar MI. Finite element study on short implants retaining mandibular overdentures with different denture materials in severely resorbed ridge. Int J Dent Oral Heal. 2020;6:1–7. Maryod WH, Taha ER, Alkaranfilly GA, El-anwar MI. Finite element study on short implants retaining mandibular overdentures with different denture materials in severely resorbed ridge. Int J Dent Oral Heal. 2020;6:1–7.
9.
go back to reference Kutkut A, Rezk M, Zephyr D, Dawson D, Frazer R, Al-Sabbagh M. Immediate loading of unsplinted implant retained mandibular overdenture: a randomized controlled clinical study. J Oral Implantol. 2019;45:378–89.CrossRefPubMed Kutkut A, Rezk M, Zephyr D, Dawson D, Frazer R, Al-Sabbagh M. Immediate loading of unsplinted implant retained mandibular overdenture: a randomized controlled clinical study. J Oral Implantol. 2019;45:378–89.CrossRefPubMed
11.
go back to reference Dantas IDS, de Souza MBC, de Siqueira Torres Morais ST, da Fonte Porto Carreiro A, Barbosa GAS. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review. Braz Oral Res. 2014;28:74–80.PubMed Dantas IDS, de Souza MBC, de Siqueira Torres Morais ST, da Fonte Porto Carreiro A, Barbosa GAS. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review. Braz Oral Res. 2014;28:74–80.PubMed
12.
go back to reference Matthys C, Vervaeke S, Besseler J, Doornewaard R, Dierens M, De Bruyn H. Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: Implant results, patient-related outcome, and prosthetic aftercare. Clin Implant Dent Relat Res. 2019;21:835–44.CrossRefPubMed Matthys C, Vervaeke S, Besseler J, Doornewaard R, Dierens M, De Bruyn H. Five years follow-up of mandibular 2-implant overdentures on locator or ball abutments: Implant results, patient-related outcome, and prosthetic aftercare. Clin Implant Dent Relat Res. 2019;21:835–44.CrossRefPubMed
13.
go back to reference Choi J-W, Yun B-H, Jeong C-M, Huh J-B. Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures. Int J Oral Maxillofac Implants. 2018;33:1079–88.CrossRefPubMed Choi J-W, Yun B-H, Jeong C-M, Huh J-B. Retentive properties of two stud attachments with polyetherketoneketone or nylon insert in mandibular implant overdentures. Int J Oral Maxillofac Implants. 2018;33:1079–88.CrossRefPubMed
14.
go back to reference Marin DOM, Leite ARP, de Oliveira Junior NM, Paleari AG, Pero AC, Compagnoni MA. Retention force and wear characteristics of three attachment systems after dislodging cycles. Braz Dent J. 2018;29:576–82.CrossRefPubMed Marin DOM, Leite ARP, de Oliveira Junior NM, Paleari AG, Pero AC, Compagnoni MA. Retention force and wear characteristics of three attachment systems after dislodging cycles. Braz Dent J. 2018;29:576–82.CrossRefPubMed
15.
go back to reference Li P, Hasselbeck D, Unkovskiy A, Sharghi F, Spintzyk S. Retentive characteristics of a polyetheretherketone post-core restoration with polyvinylsiloxane attachments. Polymers (Basel). 2020;12:1–9. Li P, Hasselbeck D, Unkovskiy A, Sharghi F, Spintzyk S. Retentive characteristics of a polyetheretherketone post-core restoration with polyvinylsiloxane attachments. Polymers (Basel). 2020;12:1–9.
17.
go back to reference Atashrazm P, Dashti MH, Alavijeh LZ, Azarmaeh SMS. The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study. J Indian Prosthodont Soc. 2014;14:72–7.CrossRefPubMed Atashrazm P, Dashti MH, Alavijeh LZ, Azarmaeh SMS. The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study. J Indian Prosthodont Soc. 2014;14:72–7.CrossRefPubMed
18.
go back to reference da Fontoura Frasca LC, Castro Mattia PR, Botega DMRE, Da Fontoura Frasca LC, Castro Mattia PR, Botega DM, Rivaldo EG. Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components. Implant Dent. 2014;23:451–5.PubMed da Fontoura Frasca LC, Castro Mattia PR, Botega DMRE, Da Fontoura Frasca LC, Castro Mattia PR, Botega DM, Rivaldo EG. Evaluation of retention forces and resistance to fatigue of attachment systems for overdentures: plastic and metal components. Implant Dent. 2014;23:451–5.PubMed
19.
go back to reference Schweiger J, Edelhoff DGJ. 3D printing in digital prosthetic dentistry: an overview of recent developments in additive manufacturing. Clin Med. 2021;10:2010. Schweiger J, Edelhoff DGJ. 3D printing in digital prosthetic dentistry: an overview of recent developments in additive manufacturing. Clin Med. 2021;10:2010.
20.
go back to reference Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FRMP. 3D and 4D printing in dentistry and maxillofacial surgery: printing techniques, materials, and applications. Acta Biomater. 2021;1:26–49.CrossRef Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FRMP. 3D and 4D printing in dentistry and maxillofacial surgery: printing techniques, materials, and applications. Acta Biomater. 2021;1:26–49.CrossRef
21.
go back to reference El Aziz MSA, El Sattar Abd El Megid Tella EA. Fully digital workflow for reinforced mandibular implant overdenture – a novel method. J Indian Prosthodont Soc. 2022;22:205–9.CrossRefPubMedPubMedCentral El Aziz MSA, El Sattar Abd El Megid Tella EA. Fully digital workflow for reinforced mandibular implant overdenture – a novel method. J Indian Prosthodont Soc. 2022;22:205–9.CrossRefPubMedPubMedCentral
22.
go back to reference Kuo H, Kuo P, Bittner N, Cavallaro J. Assessment of the changes in retention and surface topography of attachments for maxillary 4-implant-retained overdentures. J Prosthet Dent. 2021;5:413. Kuo H, Kuo P, Bittner N, Cavallaro J. Assessment of the changes in retention and surface topography of attachments for maxillary 4-implant-retained overdentures. J Prosthet Dent. 2021;5:413.
23.
go back to reference Ramadan RE, Mohamed FS. Retention of mandibular implant-retained overdentures with two different attachment designs: an in vitro study. J Prosthet Dent. 2020;1:738. Ramadan RE, Mohamed FS. Retention of mandibular implant-retained overdentures with two different attachment designs: an in vitro study. J Prosthet Dent. 2020;1:738.
24.
go back to reference Cristache CM, Tudor I, Moraru L, Cristache G, Lanza A, Burlibasa M, Cristache CM, Tudor I, Moraru L, Cristache G, Lanza A, et al. Digital workflow in maxillofacial prosthodontics—an update on defect data acquisition, editing and design using open-source and commercial available software. Appl Sci. 2021;11:1–19.CrossRef Cristache CM, Tudor I, Moraru L, Cristache G, Lanza A, Burlibasa M, Cristache CM, Tudor I, Moraru L, Cristache G, Lanza A, et al. Digital workflow in maxillofacial prosthodontics—an update on defect data acquisition, editing and design using open-source and commercial available software. Appl Sci. 2021;11:1–19.CrossRef
25.
go back to reference Oancea L, Burlibasa M, Petre AE, Panaitescu E, Cristache CM. Predictive model for occlusal vertical dimension determination and digital preservation with three-dimensional facial scanning. Appl Sci. 2020;10:7890.CrossRef Oancea L, Burlibasa M, Petre AE, Panaitescu E, Cristache CM. Predictive model for occlusal vertical dimension determination and digital preservation with three-dimensional facial scanning. Appl Sci. 2020;10:7890.CrossRef
26.
go back to reference Cristache CM, Totu EE, Iorgulescu G, et al. Eighteen months follow-up with patient-centered outcomes assessment of complete dentures manufactured using a hybrid nanocomposite and additive CAD/CAM protocol. J Clin Med. 2020;9:324.CrossRefPubMedPubMedCentral Cristache CM, Totu EE, Iorgulescu G, et al. Eighteen months follow-up with patient-centered outcomes assessment of complete dentures manufactured using a hybrid nanocomposite and additive CAD/CAM protocol. J Clin Med. 2020;9:324.CrossRefPubMedPubMedCentral
27.
go back to reference Tian Y, Chen C, Xu X, Wang J, Hou X, Li K, Lu X, Shi H, Lee E-S, Jiang HB. A review of 3D printing in dentistry: technologies, affecting factors, and applications. Scanning. 2021;2021:1.CrossRef Tian Y, Chen C, Xu X, Wang J, Hou X, Li K, Lu X, Shi H, Lee E-S, Jiang HB. A review of 3D printing in dentistry: technologies, affecting factors, and applications. Scanning. 2021;2021:1.CrossRef
28.
go back to reference Pillai S, Upadhyay A, Khayambashi P, et al. Dental 3D-printing: transferring art from the laboratories to the clinics. Polym. 2021;13:157.CrossRef Pillai S, Upadhyay A, Khayambashi P, et al. Dental 3D-printing: transferring art from the laboratories to the clinics. Polym. 2021;13:157.CrossRef
29.
go back to reference Unkovskiy A, Spintzyk S, Brom J, Huettig FKC. Direct 3D printing of silicone facial prostheses: a preliminary experience in digital workflow. J Prosthet Dent. 2018;120:303–8.CrossRefPubMed Unkovskiy A, Spintzyk S, Brom J, Huettig FKC. Direct 3D printing of silicone facial prostheses: a preliminary experience in digital workflow. J Prosthet Dent. 2018;120:303–8.CrossRefPubMed
30.
go back to reference Reda KM, El-Torky IR, El-Gendy MN, Reda KM, El-Torky IR, El-Gendy M. In vitro retention force measurement for three different attachment systems for implant-retained overdenture. J Indian Prosthodont Soc. 2016;16:380–5.CrossRefPubMedPubMedCentral Reda KM, El-Torky IR, El-Gendy MN, Reda KM, El-Torky IR, El-Gendy M. In vitro retention force measurement for three different attachment systems for implant-retained overdenture. J Indian Prosthodont Soc. 2016;16:380–5.CrossRefPubMedPubMedCentral
31.
go back to reference Koutsoukis T, Zinelis S, Eliades G, Al-Wazzan K, Rifaiy M, Al Jabbari YS. Selective laser melting technique of Co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques. J Prosthodont. 2015;24:303–12.CrossRefPubMed Koutsoukis T, Zinelis S, Eliades G, Al-Wazzan K, Rifaiy M, Al Jabbari YS. Selective laser melting technique of Co-Cr dental alloys: a review of structure and properties and comparative analysis with other available techniques. J Prosthodont. 2015;24:303–12.CrossRefPubMed
32.
go back to reference Yu W, Zhang H, Lan A, Yang S, Zhang J, Wang H, Zhou Z, Zhou Y, Zhao J, Jiang Z. Enhanced bioactivity and osteogenic property of carbon fiber reinforced polyetheretherketone composites modified with amino groups. Colloids Surf B Biointerfaces. 2020;193:111098.CrossRefPubMed Yu W, Zhang H, Lan A, Yang S, Zhang J, Wang H, Zhou Z, Zhou Y, Zhao J, Jiang Z. Enhanced bioactivity and osteogenic property of carbon fiber reinforced polyetheretherketone composites modified with amino groups. Colloids Surf B Biointerfaces. 2020;193:111098.CrossRefPubMed
33.
go back to reference Qin L, Yao S, Zhao J, Zhou C, Oates TW, Weir MD, Wu J, Xu HHK. Review on development and dental applications of polyetheretherketone-based biomaterials and restorations. Materials (Basel). 2021;14:408.CrossRefPubMedPubMedCentral Qin L, Yao S, Zhao J, Zhou C, Oates TW, Weir MD, Wu J, Xu HHK. Review on development and dental applications of polyetheretherketone-based biomaterials and restorations. Materials (Basel). 2021;14:408.CrossRefPubMedPubMedCentral
34.
go back to reference Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M, Papathanasiou I, Kamposiora P, Papavasiliou G, et al. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health. 2020;217:1–11. Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M, Papathanasiou I, Kamposiora P, Papavasiliou G, et al. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health. 2020;217:1–11.
35.
go back to reference Chen T, Chen Q, Fu H, et al. Construction and performance evaluation of a sustained release implant material polyetheretherketone with antibacterial properties. Mater Sci Eng C, Mater Biol Appl. 2021;126:112109.CrossRefPubMed Chen T, Chen Q, Fu H, et al. Construction and performance evaluation of a sustained release implant material polyetheretherketone with antibacterial properties. Mater Sci Eng C, Mater Biol Appl. 2021;126:112109.CrossRefPubMed
36.
go back to reference Kobayashi M, Srinivasan M, Ammann P, Perriard J, Ohkubo C, Müller F, et al. Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems. Clin Oral Implant Res. 2014;25:426–34.CrossRef Kobayashi M, Srinivasan M, Ammann P, Perriard J, Ohkubo C, Müller F, et al. Effects of in vitro cyclic dislodging on retentive force and removal torque of three overdenture attachment systems. Clin Oral Implant Res. 2014;25:426–34.CrossRef
37.
go back to reference Rutkunas V, Mizutani H, Takahashi HIN. Wear simulation effects on overdenture stud attachments. Dent Mater J. 2011;30:845–53.CrossRefPubMed Rutkunas V, Mizutani H, Takahashi HIN. Wear simulation effects on overdenture stud attachments. Dent Mater J. 2011;30:845–53.CrossRefPubMed
38.
39.
go back to reference Guttal SS, Nadiger RKAS. Effect of insertion and removal of tooth supported overdentures on retention strength and fatigue resistance of two commercially available attachment systems. Int J Prosthodont Restor Dent. 2012;2:47–51. Guttal SS, Nadiger RKAS. Effect of insertion and removal of tooth supported overdentures on retention strength and fatigue resistance of two commercially available attachment systems. Int J Prosthodont Restor Dent. 2012;2:47–51.
40.
go back to reference Gujjalapudi M, Verma AK, Magar SM, Balaji DL, Dang GSBA. An in vitro assessment of retention force for implant retained overdentures using all polyetheretherketone, zirconia, and titanium attachments. Int J Curr Res Rev. 2021;13:75.CrossRef Gujjalapudi M, Verma AK, Magar SM, Balaji DL, Dang GSBA. An in vitro assessment of retention force for implant retained overdentures using all polyetheretherketone, zirconia, and titanium attachments. Int J Curr Res Rev. 2021;13:75.CrossRef
41.
go back to reference Burns DR, Unger JW, Elswick RK, Beck DA. Prospective clinical evaluation of mandibular implant overdentures: Part I-retention, stability, and tissue response. J Prosthet Dent. 1995;73:354–63.CrossRefPubMed Burns DR, Unger JW, Elswick RK, Beck DA. Prospective clinical evaluation of mandibular implant overdentures: Part I-retention, stability, and tissue response. J Prosthet Dent. 1995;73:354–63.CrossRefPubMed
42.
go back to reference Kamal Emera R, Elgamal M, Altonbary G. Retention force of all-zirconia, all-polyetheretherketone, and zirconia-polyetheretherketone telescopic attachments for implant-retained overdentures: in vitro comparative study. J Dent Implant. 2020;10:78.CrossRef Kamal Emera R, Elgamal M, Altonbary G. Retention force of all-zirconia, all-polyetheretherketone, and zirconia-polyetheretherketone telescopic attachments for implant-retained overdentures: in vitro comparative study. J Dent Implant. 2020;10:78.CrossRef
43.
go back to reference Tehini G, Baba NZ, Majzoub Z, Nahas P, Berberi A, Rifai K. In vitro effect of mastication on the retention and wear of locator attachments in a flat mandibular ridge model. J Prosthodont. 2019;28:e744–51.CrossRefPubMed Tehini G, Baba NZ, Majzoub Z, Nahas P, Berberi A, Rifai K. In vitro effect of mastication on the retention and wear of locator attachments in a flat mandibular ridge model. J Prosthodont. 2019;28:e744–51.CrossRefPubMed
Metadata
Title
Novel CAD–CAM fabrication of a custom-made ball attachment retentive housing: an in-vitro study
Authors
Hussein G. El Charkawi
Medhat Sameh Abdelaziz
Publication date
01-12-2023
Publisher
BioMed Central
Published in
European Journal of Medical Research / Issue 1/2023
Electronic ISSN: 2047-783X
DOI
https://doi.org/10.1186/s40001-023-01498-5

Other articles of this Issue 1/2023

European Journal of Medical Research 1/2023 Go to the issue