Published in: Journal of Robotic Surgery 6/2023

Open Access 04-09-2023 | Neuromonitoring | Research

Integrating navigation assistance for redirecting freehanded spinal instrumentation: experience and technique

Authors: Lauren Stone, Marin McDonald, Luke Wojdyla, Joseph A. Osorio

Published in: Journal of Robotic Surgery | Issue 6/2023

Login to get access

Abstract

Retrospective review of all spinal fusions > 3 levels involving the thoracolumbar and/or sacroiliac at a single institution, by a single surgeon between 3/12/2020 and 8/13/2021 were reviewed. All screws that were secondarily navigated after identified as misdirected on intraoperative CT scan were included. Neuromonitoring reports were culled for mA threshold to triggered EMG response for all redirected screws. Intraoperative, post-de novo screw placement images (fluoroscopy scout and intraoperative CT) and post-redirection intraoperative scoliosis films and post-operative scoliosis films were independently reviewed by a senior neuroradiologist. Fifty redirected screws in the thoracic, lumbar, sacral, and ilium were identified as misdirected and redirected via navigation. The new trajectory of all screws was confirmed satisfactory by independent review between a senior neuroradiologist and neurosurgeon. Four screws could not be verified by post-operative imaging (4/50, 8%). All triggered EMG stimulated > 15 mA. No screws required return to the operating room for revision. No patients experienced a post-operative deficit. Redirection of misdirected thoracolumbar and sacroiliac screws can be performed using intraoperative CT and navigation as a means to detect and directly visualize appropriate placement.
Literature
1.
go back to reference Kothe R, Panjabi MM, Liu W (1997) Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. Biomech Investig Spine 22:1836–1842 Kothe R, Panjabi MM, Liu W (1997) Multidirectional instability of the thoracic spine due to iatrogenic pedicle injuries during transpedicular fixation. Biomech Investig Spine 22:1836–1842
3.
go back to reference Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614CrossRefPubMed Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25:606–614CrossRefPubMed
4.
go back to reference Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240CrossRefPubMedPubMedCentral Laine T, Lund T, Ylikoski M, Lohikoski J, Schlenzka D (2000) Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 9:235–240CrossRefPubMedPubMedCentral
5.
go back to reference Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed Laine T, Schlenzka D, Makitalo K, Tallroth K, Nolte LP, Visarius H (1997) Improved accuracy of pedicle screw insertion with computer assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254–1258CrossRefPubMed
7.
9.
go back to reference George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ (1991) Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine 16:181–184PubMed George DC, Krag MH, Johnson CC, Van Hal ME, Haugh LD, Grobler LJ (1991) Hole preparation techniques for transpedicle screws. Effect on pull-out strength from human cadaveric vertebrae. Spine 16:181–184PubMed
13.
go back to reference Mikula AL, Williams SK, Anderson PA (2016) The use of intraoperative triggered electromyography to detect misplaced pedicle screws: a systematic review and meta-analysis. J Neurosurg Spine SPI 24(4):624–638CrossRef Mikula AL, Williams SK, Anderson PA (2016) The use of intraoperative triggered electromyography to detect misplaced pedicle screws: a systematic review and meta-analysis. J Neurosurg Spine SPI 24(4):624–638CrossRef
14.
go back to reference Wagner C (2018) Robotics in neurosurgery. Congress of Neurological Surgeons Wagner C (2018) Robotics in neurosurgery. Congress of Neurological Surgeons
17.
go back to reference Kassis SZ, Abukwedar LK, Msaddi AK, Majer CN, Othman W (2016) Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation. Eur Spine J 25(6):1724–1728. https://doi.org/10.1007/s00586-015-3973-3. (PMID: 25921653)CrossRefPubMed Kassis SZ, Abukwedar LK, Msaddi AK, Majer CN, Othman W (2016) Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation. Eur Spine J 25(6):1724–1728. https://​doi.​org/​10.​1007/​s00586-015-3973-3. (PMID: 25921653)CrossRefPubMed
Metadata
Title
Integrating navigation assistance for redirecting freehanded spinal instrumentation: experience and technique
Authors
Lauren Stone
Marin McDonald
Luke Wojdyla
Joseph A. Osorio
Publication date
04-09-2023
Publisher
Springer London
Published in
Journal of Robotic Surgery / Issue 6/2023
Print ISSN: 1863-2483
Electronic ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-023-01686-9

Other articles of this Issue 6/2023

Journal of Robotic Surgery 6/2023 Go to the issue