Skip to main content
Top
Published in: Journal of Maxillofacial and Oral Surgery 1/2024

14-10-2023 | Nerve Block | COMPARATIVE STUDY

Efficacy and Reliability of Single Tooth Anesthesia (STA) for Surgical Removal of Impacted Wisdom Teeth: A Comparative Study

Authors: Manikandhan Ramanathan, Sandeep Ramanuj, Keerthana Ponvel

Published in: Journal of Maxillofacial and Oral Surgery | Issue 1/2024

Login to get access

Abstract

Introduction

Single tooth anesthesia via intra-ligamentary injections has long been used to provide localized pain control with minimal discomfort while avoiding undesirable effects like lip numbness, mainly in pediatric population with definite success. In this study, we aimed to assess the efficacy of single tooth anesthesia (STA) via intra-ligamentary injections using WAND® STA in the surgical removal of impacted third molar.

Methodology

Sixty patients were randomly divided into two groups of 30 each where Group I (study group) received local anesthesia via STA system with 4% articaine and Group II (control group) received conventional injection, that is, inferior alveolar nerve block, (IANB) with 4% articaine. Assessment of the effectiveness of the anesthesia was made by noting the onset of action, failure of anesthesia, intra-operative pain and necessity for additional injection. Additional effects such as lip numbness were also noted. Patients were evaluated for pain and discomfort after 24 h.

Results

The difference between the mean time for onset of action for STA injections and conventional block and the mean difference in the onset of action between both groups was 2.2 (± 0.25) minutes which was statistically significant (p < 0.05). Statistically significant difference in VAS score was noted only during tooth elevation with Group I reporting higher VAS score than Group II. Additional blocks were indicated in 6.7% for lingual block and 50% for long buccal nerve block in Group I and repetition of long buccal nerve block was indicated in 23.3% patients in group II. Postoperative pain and trismus was found to be higher in Group II.

Conclusion

In spite of some limits in the extent of anesthesia achieved, WAND® STA was seen to be able to achieve adequate anesthesia for surgical removal of impacted third molar and is a viable alternative, particularly in patients where blocks are contraindicated due to systemic conditions.
Appendix
Available only for authorised users
Literature
1.
go back to reference Subbiya A, Vikash R, Anuradha B, Mitthra S (2020) Failure of inferior alveolar nerve block and how to overcome it: a review. Eur J Mol Clin Med 7(5):2020 Subbiya A, Vikash R, Anuradha B, Mitthra S (2020) Failure of inferior alveolar nerve block and how to overcome it: a review. Eur J Mol Clin Med 7(5):2020
2.
go back to reference Kaufman E, Weinstein P, Milgrom P (1984) Difficulties in achieving local anesthesia. J Am Dent Assoc 108:205–208CrossRefPubMed Kaufman E, Weinstein P, Milgrom P (1984) Difficulties in achieving local anesthesia. J Am Dent Assoc 108:205–208CrossRefPubMed
3.
go back to reference Burtscher D, Dalla Torre D (2019) Intraligamentary anesthesia–a brief review of an underestimated anesthetic technique. Oral Heal Care 4:1–3 Burtscher D, Dalla Torre D (2019) Intraligamentary anesthesia–a brief review of an underestimated anesthetic technique. Oral Heal Care 4:1–3
4.
go back to reference Kumar TY, John JB, Asokan S, Priya PG, Punithavathy R, Praburajan V (2015) Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe. J Indian Soc Pedod Prev Dent 33:223–228CrossRef Kumar TY, John JB, Asokan S, Priya PG, Punithavathy R, Praburajan V (2015) Behavioral response and pain perception to computer controlled local anesthetic delivery system and cartridge syringe. J Indian Soc Pedod Prev Dent 33:223–228CrossRef
5.
go back to reference Garret-Bernardin A, Cantile T, D’Antò V, Galanakis A, Fauxpoint G, Ferrazzano GF, De Rosa S, Vallogini G, Romeo U, Galeotti A (2017) Research article pain experience and behavior management in pediatric dentistry: a comparison between traditional local anesthesia and the wand computerized delivery system. Dentist Garret-Bernardin A, Cantile T, D’Antò V, Galanakis A, Fauxpoint G, Ferrazzano GF, De Rosa S, Vallogini G, Romeo U, Galeotti A (2017) Research article pain experience and behavior management in pediatric dentistry: a comparison between traditional local anesthesia and the wand computerized delivery system. Dentist
6.
go back to reference Froum SJ, Tarnow D, Caiazzo A, Hochman MN (2000) Histologic response to intraligament injections using a computerized local anesthetic delivery system. A pilot study in mini-swine. J Periodontol 71:1453–1459CrossRefPubMed Froum SJ, Tarnow D, Caiazzo A, Hochman MN (2000) Histologic response to intraligament injections using a computerized local anesthetic delivery system. A pilot study in mini-swine. J Periodontol 71:1453–1459CrossRefPubMed
7.
go back to reference Kwak EJ, Pang NS, Park W et al (2016) Computer-controlled local anesthetic delivery for painless anesthesia: a literature review. J Dental Anesth Pain Med 16(2):81–88CrossRef Kwak EJ, Pang NS, Park W et al (2016) Computer-controlled local anesthetic delivery for painless anesthesia: a literature review. J Dental Anesth Pain Med 16(2):81–88CrossRef
8.
go back to reference Saxena P, Gupta SK, Newaskar V, Chandra A (2013) Advances in dental local anesthesia techniques and devices: an update. Natl J Maxillofac Surg 4(1):19–24CrossRefPubMedPubMedCentral Saxena P, Gupta SK, Newaskar V, Chandra A (2013) Advances in dental local anesthesia techniques and devices: an update. Natl J Maxillofac Surg 4(1):19–24CrossRefPubMedPubMedCentral
9.
go back to reference Fischer G (1933) Local anesthesia in dentistry, 4th edn. Lea & Febiger, Philadelphia Fischer G (1933) Local anesthesia in dentistry, 4th edn. Lea & Febiger, Philadelphia
10.
go back to reference Cassamani C (1924) Une Nouvelle Technique d’Anesthesia Intraliga–mentarire. [PhD thesis]. Paris Cassamani C (1924) Une Nouvelle Technique d’Anesthesia Intraliga–mentarire. [PhD thesis]. Paris
11.
go back to reference Pashley EL, Nelson R, Pashley DH (1981) Pressures created by dental injections. J Dental Res 60:1742–1748CrossRef Pashley EL, Nelson R, Pashley DH (1981) Pressures created by dental injections. J Dental Res 60:1742–1748CrossRef
12.
go back to reference Hochman MN (2007) Single-tooth anesthesia: pressure-sensing technology provides innovative advancement in the field of dental local anesthesia. Compend Contin Educ Dent 28:168–188 Hochman MN (2007) Single-tooth anesthesia: pressure-sensing technology provides innovative advancement in the field of dental local anesthesia. Compend Contin Educ Dent 28:168–188
13.
go back to reference Hochman M (2001) inventor; pressure/force computer controlled drug delivery system and the like. Assigned: Milestone Scientific, Inc. US Patent 6,200,289 Hochman M (2001) inventor; pressure/force computer controlled drug delivery system and the like. Assigned: Milestone Scientific, Inc. US Patent 6,200,289
14.
go back to reference Kämmerer PW, Adubae A, Buttchereit I, Thiem DGE, Daubländer M, Frerich B (2018) Prospective clinical study comparing intraligamentary anesthesia and inferior alveolar nerve block for extraction of posterior mandibular teeth. Clin Oral Investig 22(3):1469–1475CrossRefPubMed Kämmerer PW, Adubae A, Buttchereit I, Thiem DGE, Daubländer M, Frerich B (2018) Prospective clinical study comparing intraligamentary anesthesia and inferior alveolar nerve block for extraction of posterior mandibular teeth. Clin Oral Investig 22(3):1469–1475CrossRefPubMed
15.
go back to reference Ferrari M, Cagidiaco MC, Vichi A, Goracci C (2009) Efficacy of the computer-controlled injection system STA TM, the Ligmaject, and the dental syringe for intraligamentary anesthesia in restorative patients. Int Dent 11:4–12 Ferrari M, Cagidiaco MC, Vichi A, Goracci C (2009) Efficacy of the computer-controlled injection system STA TM, the Ligmaject, and the dental syringe for intraligamentary anesthesia in restorative patients. Int Dent 11:4–12
16.
go back to reference Nicholson JW, Berry TG, Summitt JB, Yuan CH, Witten TM (2001) Pain perception and utility: a comparison of the syringe and computerized local injection techniques. General Dent 49:167–173 Nicholson JW, Berry TG, Summitt JB, Yuan CH, Witten TM (2001) Pain perception and utility: a comparison of the syringe and computerized local injection techniques. General Dent 49:167–173
17.
go back to reference Ashkenazi M, Blumer S, Eli I (2005) Effectiveness of computerized delivery of intrasulcular anesthetic in primary molars. J Am Dent Assoc 136:1418–1425CrossRefPubMed Ashkenazi M, Blumer S, Eli I (2005) Effectiveness of computerized delivery of intrasulcular anesthetic in primary molars. J Am Dent Assoc 136:1418–1425CrossRefPubMed
18.
go back to reference Versloot J, Veerkamp JS, Hoogstraten J (2005) Computerized anesthesia delivery system vs. traditional syringe: comparing pain and pain-related behavior in children. Eur J Oral Sci 113:488–493CrossRefPubMed Versloot J, Veerkamp JS, Hoogstraten J (2005) Computerized anesthesia delivery system vs. traditional syringe: comparing pain and pain-related behavior in children. Eur J Oral Sci 113:488–493CrossRefPubMed
19.
go back to reference Campanella V, Libonati A, Nardi R, Angotti V, Gallusi G, Montemurro E et al (2018) Single tooth anesthesia versus conventional anesthesia: a cross-over study. Clin Oral Investig 22:3205–3213CrossRefPubMed Campanella V, Libonati A, Nardi R, Angotti V, Gallusi G, Montemurro E et al (2018) Single tooth anesthesia versus conventional anesthesia: a cross-over study. Clin Oral Investig 22:3205–3213CrossRefPubMed
20.
go back to reference Kämmerer PW, Schiegnitz E, von Haussen T, Shabazfar N, Kämmerer P, Willershausen B et al (2015) Clinical efficacy of a computerised device (STATM) and a pressure syringe (VarioJect INTRA TM) for intraligamentary anaesthesia. Eur J Dent Educ 19:16–22CrossRefPubMed Kämmerer PW, Schiegnitz E, von Haussen T, Shabazfar N, Kämmerer P, Willershausen B et al (2015) Clinical efficacy of a computerised device (STATM) and a pressure syringe (VarioJect INTRA TM) for intraligamentary anaesthesia. Eur J Dent Educ 19:16–22CrossRefPubMed
Metadata
Title
Efficacy and Reliability of Single Tooth Anesthesia (STA) for Surgical Removal of Impacted Wisdom Teeth: A Comparative Study
Authors
Manikandhan Ramanathan
Sandeep Ramanuj
Keerthana Ponvel
Publication date
14-10-2023
Publisher
Springer India
Published in
Journal of Maxillofacial and Oral Surgery / Issue 1/2024
Print ISSN: 0972-8279
Electronic ISSN: 0974-942X
DOI
https://doi.org/10.1007/s12663-023-02017-z

Other articles of this Issue 1/2024

Journal of Maxillofacial and Oral Surgery 1/2024 Go to the issue