Published in: BMC Anesthesiology 1/2024

Open Access 01-12-2024 | Nerve Block | Research

Comparison of diffusion ranges at different local anesthetic volumes during superior laryngeal nerve block

Authors: Yin Bao, Huijun Wang, Lifeng Li, Hongbo Xu, Yun Li, Guyan Wang

Published in: BMC Anesthesiology | Issue 1/2024

Login to get access

Abstract

Objectives

Ultrasound-guided superior laryngeal nerve (SLN) block is a practical and painless approach to avoid the hemodynamic stress response during endotracheal intubation and relieve sore throat after laryngeal surgery. The main purpose of this study was to establish an optimal dosage of local anesthetic when performing SLN block to help anesthetists balance analgesia and side effects.

Methods

Twenty fresh larynx specimens were obtained immediately after resection and then injected with 2-, 3-, 4-, or 5- mL of a lidocaine-blue dye mixture at bilateral SLN puncture sites. Superficial areas of deposited blue dye were measured. Dye leakage and surrounding dyed tissue were recorded. Another 40 patients were included in the ultrasound investigation. Distances between the internal branch of the SLN (iSLN) and adjacent structures were calculated.

Results

The dye spread area was greater with the administration of larger doses, especially to the visceral space. A 2- or 3-mL injection of local anesthetic was sufficient to infiltrate the SLN gap. A higher incidence of dye leaking out of the thyrohyoid membrane and anterior epiglottis space was observed; furthermore, there was substantially more dyed hyoid/thyroid cartilage with 4 and 5 mL of injected dye mixture than 2 mL. There was no significant difference between the specimen and ultrasound measurements of for length of iSLN-adjacent structures.

Conclusions

In the Chinese population, 2- or 3- mL of local anesthetic is a safe dose during SLN block. A larger volume could overflow from the cavity to cause complications. The thyrohyoid membrane combined with the superior laryngeal artery is a reliable target for positioning the iSLN during ultrasound-guided regional anesthesia.
Appendix
Available only for authorised users
Literature
1.
go back to reference Monsó A, et al. A new application for superior laryngeal nerve block: treatment or prevention of laryngospasm and stridor. Reg Anesth Pain Med. 1999;24(2):186–7.CrossRefPubMed Monsó A, et al. A new application for superior laryngeal nerve block: treatment or prevention of laryngospasm and stridor. Reg Anesth Pain Med. 1999;24(2):186–7.CrossRefPubMed
2.
go back to reference Zhipeng L, Meiyi H, Meirong W, et al. Ultrasound-guided internal branch of superior laryngeal nerve block on postoperative sore throat: A randomized controlled trial. PLoS One. 2020;15(11):e0241834. Zhipeng L, Meiyi H, Meirong W, et al. Ultrasound-guided internal branch of superior laryngeal nerve block on postoperative sore throat: A randomized controlled trial. PLoS One. 2020;15(11):e0241834.
3.
go back to reference Potenza AS, Araujo Filho VJF, Cernea CR. Injury of the external branch of the superior laryngeal nerve in thyroid surgery. Gland Surg. 2017;6(5):552–62.CrossRefPubMedPubMedCentral Potenza AS, Araujo Filho VJF, Cernea CR. Injury of the external branch of the superior laryngeal nerve in thyroid surgery. Gland Surg. 2017;6(5):552–62.CrossRefPubMedPubMedCentral
4.
go back to reference Wiles JR, Kelly J, Mostafa SM. Hypotension and bradycardia following superior laryngeal nerve block. Br J Anaesth. 1989;63(1):125–7.CrossRefPubMed Wiles JR, Kelly J, Mostafa SM. Hypotension and bradycardia following superior laryngeal nerve block. Br J Anaesth. 1989;63(1):125–7.CrossRefPubMed
5.
go back to reference Hsu CH, et al. Convulsions during superior laryngeal nerve block–a case report. Acta Anaesthesiol Sin. 2000;38(2):93–6.PubMed Hsu CH, et al. Convulsions during superior laryngeal nerve block–a case report. Acta Anaesthesiol Sin. 2000;38(2):93–6.PubMed
6.
7.
go back to reference Boonstra H, et al. Cervical tissue shrinkage by formaldehyde fixation, paraffin wax embedding, section cutting and mounting. Virchows Arch A Pathol Anat Histopathol. 1983;402(2):195–201.CrossRefPubMed Boonstra H, et al. Cervical tissue shrinkage by formaldehyde fixation, paraffin wax embedding, section cutting and mounting. Virchows Arch A Pathol Anat Histopathol. 1983;402(2):195–201.CrossRefPubMed
8.
go back to reference Barberet G, et al. Ultrasound description of a superior laryngeal nerve space as an anatomical basis for echoguided regional anaesthesia. Br J Anaesth. 2012;109(1):126–8.ADSCrossRefPubMed Barberet G, et al. Ultrasound description of a superior laryngeal nerve space as an anatomical basis for echoguided regional anaesthesia. Br J Anaesth. 2012;109(1):126–8.ADSCrossRefPubMed
9.
go back to reference Grevstad U, Jæger P, Sørensen JK, et al. The Effect of Local Anesthetic Volume Within the Adductor Canal on Quadriceps Femoris Function Evaluated by Electromyography: A Randomized, Observer- and Subject-Blinded. Placebo-Controlled Study in Volunteers. Anesth Analg. 2016;123(2):493–500. Grevstad U, Jæger P, Sørensen JK, et al. The Effect of Local Anesthetic Volume Within the Adductor Canal on Quadriceps Femoris Function Evaluated by Electromyography: A Randomized, Observer- and Subject-Blinded. Placebo-Controlled Study in Volunteers. Anesth Analg. 2016;123(2):493–500.
10.
go back to reference Stopar-Pintaric T, Vlassakov K, Azman J, Cvetko E. The thyrohyoid membrane as a target for ultrasonography-guided block of the internal branch of the superior laryngeal nerve. J Clin Anesth. 2015;27(7):548–52.CrossRefPubMed Stopar-Pintaric T, Vlassakov K, Azman J, Cvetko E. The thyrohyoid membrane as a target for ultrasonography-guided block of the internal branch of the superior laryngeal nerve. J Clin Anesth. 2015;27(7):548–52.CrossRefPubMed
11.
go back to reference Goldstein A. Errors in ultrasound digital image distance measurements. Ultrasound Med Biol. 2000;26(7):1125–32.CrossRefPubMed Goldstein A. Errors in ultrasound digital image distance measurements. Ultrasound Med Biol. 2000;26(7):1125–32.CrossRefPubMed
Metadata
Title
Comparison of diffusion ranges at different local anesthetic volumes during superior laryngeal nerve block
Authors
Yin Bao
Huijun Wang
Lifeng Li
Hongbo Xu
Yun Li
Guyan Wang
Publication date
01-12-2024
Publisher
BioMed Central
Keyword
Nerve Block
Published in
BMC Anesthesiology / Issue 1/2024
Electronic ISSN: 1471-2253
DOI
https://doi.org/10.1186/s12871-024-02490-0