Skip to main content
Top
Published in: BMC Pregnancy and Childbirth 1/2020

Open Access 01-12-2020 | Research article

Neonatal transitional support with intact umbilical cord in assisted vaginal deliveries: a quality-improvement cohort study

Authors: Elisabeth Sæther, Friedrich Reinhart-Van Gülpen, Christer Jensen, Tor Åge Myklebust, Beate Horsberg Eriksen

Published in: BMC Pregnancy and Childbirth | Issue 1/2020

Login to get access

Abstract

Background

Deferring cord clamping has proven benefits for both term and preterm infants, and recent studies have demonstrated better cardio-respiratory stability if clamping is based on the infant’s physiology, and whether the infant has breathed. Nevertheless, current guidelines for neonatal resuscitation still recommend early cord clamping (ECC) for compromised babies, unless equipment and competent personnel to resuscitate the baby are available at the mother’s bedside. The objective of this quality improvement cohort study was to evaluate whether implementing a new delivery room protocol involving mobile resuscitation equipment (LifeStart™) reduced the prevalence of ECC in assisted vaginal deliveries.

Methods

Data on cord clamping and transitional care were collected 8 months before and 8 months after implementing the new protocol. The Model for Improvement was applied to identify drivers and obstacles to practice change. Statistical Process Control analysis was used to demonstrate signals of improvement, and whether these changes were sustainable. Multivariate logistic regression was used to evaluate the impact of the new protocol on the primary outcome, adjusted for possible confounders.

Results

Overall prevalence of ECC dropped from 13 to 1% (P < 0.01), with a 98% relative risk reduction for infants needing transitional support on a resuscitation table (adjusted OR 0.02, P < 0.001). Mean cord clamping time increased by 43% (p < 0.001). Although fewer infants were placed directly on mothers’ chest (n = 43 [42%] vs n = 69 [75.0%], P < 0.001), there were no significant differences in needs for immediate transitional care or transfers to Neonatal Intensive Care Unit. A pattern of improvement was seen already before the intervention, especially after mandatory educational sessions and cross-professional simulation training.

Conclusions

A new delivery-room protocol involving mobile resuscitation equipment successfully eliminated early cord clamping in assisted vaginal deliveries of term and near-term infants. A systematic approach, like the Model for Improvement, seemed crucial for both achieving and sustaining the desired results.

Trial registration

The study was approved as a service evaluation as defined by the Regional Committee for Medical and Health Research Ethics (2018/​1755/​REK midt).
Literature
4.
go back to reference Sundström AK, Rosén D, Rosén KG. Fosterovervåking. 1st ed. Göteborg: Neoventa Medical AB; 2000. Sundström AK, Rosén D, Rosén KG. Fosterovervåking. 1st ed. Göteborg: Neoventa Medical AB; 2000.
34.
go back to reference Langley GJ, Moen RD, Nolan KM, Nolan TW, Norman CL, Provost LP. The improvement guide: a practical approach to enhancing organizational performance: 2nd ed. San Francisco: Wiley; 2009. Langley GJ, Moen RD, Nolan KM, Nolan TW, Norman CL, Provost LP. The improvement guide: a practical approach to enhancing organizational performance: 2nd ed. San Francisco: Wiley; 2009.
Metadata
Title
Neonatal transitional support with intact umbilical cord in assisted vaginal deliveries: a quality-improvement cohort study
Authors
Elisabeth Sæther
Friedrich Reinhart-Van Gülpen
Christer Jensen
Tor Åge Myklebust
Beate Horsberg Eriksen
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Pregnancy and Childbirth / Issue 1/2020
Electronic ISSN: 1471-2393
DOI
https://doi.org/10.1186/s12884-020-03188-0

Other articles of this Issue 1/2020

BMC Pregnancy and Childbirth 1/2020 Go to the issue