Near-Infrared Fluorescence Imaging with Intraoperative Administration of Indocyanine Green for Robotic Partial Nephrectomy

Authors: Marc A. Bjurlin, Tyler R. McClintock, Michael D. Stifelman

Published in: Current Urology Reports | Issue 4/2015

Login to get access

Abstract

Near-infrared fluorescence (NIRF) imaging with intraoperative administration of indocyanine green (ICG) is a technology with emerging applications in urologic surgery. ICG is a water-soluble dye that fluoresces bright green when viewed under near-infrared light (700–1000 nm). This technology has been applied to robotic partial nephrectomy, first to potentially allow for the differentiation of renal tumor from normal parenchyma. In this application, it has been hypothesized that normal kidney tissue fluoresces green, while the tumor commonly remains hypofluorescent, thereby aiding tumor excision. Secondly, NIRF imaging with ICG has been employed to facilitate selective arterial clamping during robotic partial nephrectomy, allowing for a regional perfusion deficit in the kidney to be readily identified and therefore targeted at a given tumor. Recent studies have shown the associated decrease in global ischemia to minimize resultant loss of renal function at certain time endpoints. This review presents the most recent studies and evidence on the intraoperative administration of indocyanine green for robotic partial nephrectomy.
Literature
1.
go back to reference Binder J, Brautigam R, Jonas D, Bentas W. Robotic surgery in urology: fact or fantasy? BJU Int. 2004;94:1183–7.CrossRefPubMed Binder J, Brautigam R, Jonas D, Bentas W. Robotic surgery in urology: fact or fantasy? BJU Int. 2004;94:1183–7.CrossRefPubMed
2.
go back to reference Atug F, Castle EP, Woods M, Davis R, Thomas R. Robotics in urologic surgery: an evolving new technology. Int J Urol. 2006;13:857–63.CrossRefPubMed Atug F, Castle EP, Woods M, Davis R, Thomas R. Robotics in urologic surgery: an evolving new technology. Int J Urol. 2006;13:857–63.CrossRefPubMed
3.
go back to reference van den Berg NS, van Leeuwen FW, van der Poel HG. Fluorescence guidance in urologic surgery. Curr Opin Urol. 2012;22:109–20.CrossRefPubMed van den Berg NS, van Leeuwen FW, van der Poel HG. Fluorescence guidance in urologic surgery. Curr Opin Urol. 2012;22:109–20.CrossRefPubMed
4.
go back to reference Baker KJ. Binding of sulfobromophthalein (BSP) sodium and indocyanine green (ICG) by plasma alpha-1 lipoproteins. Proc Soc Exp Biol Med. 1966;122:957–63.CrossRefPubMed Baker KJ. Binding of sulfobromophthalein (BSP) sodium and indocyanine green (ICG) by plasma alpha-1 lipoproteins. Proc Soc Exp Biol Med. 1966;122:957–63.CrossRefPubMed
5.
go back to reference Desmettre T, Devoisselle JM, Mordon S. Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography. Surv Ophthalmol. 2000;45:15–27.CrossRefPubMed Desmettre T, Devoisselle JM, Mordon S. Fluorescence properties and metabolic features of indocyanine green (ICG) as related to angiography. Surv Ophthalmol. 2000;45:15–27.CrossRefPubMed
6.
go back to reference Tobis S, Knopf JK, Silvers CR, Marshall J, Cardin A, Wood RW, et al. Near infrared fluorescence imaging after intravenous indocyanine green: initial clinical experience with open partial nephrectomy for renal cortical tumors. Urology. 2012;79:958–64.CrossRefPubMed Tobis S, Knopf JK, Silvers CR, Marshall J, Cardin A, Wood RW, et al. Near infrared fluorescence imaging after intravenous indocyanine green: initial clinical experience with open partial nephrectomy for renal cortical tumors. Urology. 2012;79:958–64.CrossRefPubMed
7.
go back to reference Hope-Ross M, Yannuzzi LA, Gragoudas ES, Guyer DR, Slakter JS, Sorenson JA, et al. Adverse reactions due to indocyanine green. Ophthalmology. 1994;101:529–33.CrossRefPubMed Hope-Ross M, Yannuzzi LA, Gragoudas ES, Guyer DR, Slakter JS, Sorenson JA, et al. Adverse reactions due to indocyanine green. Ophthalmology. 1994;101:529–33.CrossRefPubMed
8.
go back to reference Ebert B, Riefke B, Sukowski U, Licha K. Cyanine dyes as contrast agents for near-infrared imaging in vivo: acute tolerance, pharmacokinetics, and fluorescence imaging. J Biomed Opt. 2011;16:066003.CrossRefPubMed Ebert B, Riefke B, Sukowski U, Licha K. Cyanine dyes as contrast agents for near-infrared imaging in vivo: acute tolerance, pharmacokinetics, and fluorescence imaging. J Biomed Opt. 2011;16:066003.CrossRefPubMed
9.
go back to reference Ott P, Bass L, Keiding S. The kinetics of continuously infused indocyanine green in the pig. J Pharmacokinet Biopharm. 1996;24:19–44.CrossRefPubMed Ott P, Bass L, Keiding S. The kinetics of continuously infused indocyanine green in the pig. J Pharmacokinet Biopharm. 1996;24:19–44.CrossRefPubMed
10.
go back to reference Shinohara H, Tanaka A, Kitai T, Yanabu N, Inomoto T, Satoh S, et al. Direct measurement of hepatic indocyanine green clearance with near-infrared spectroscopy: separate evaluation of uptake and removal. Hepatology. 1996;23:137–44.CrossRefPubMed Shinohara H, Tanaka A, Kitai T, Yanabu N, Inomoto T, Satoh S, et al. Direct measurement of hepatic indocyanine green clearance with near-infrared spectroscopy: separate evaluation of uptake and removal. Hepatology. 1996;23:137–44.CrossRefPubMed
11.••
go back to reference Bjurlin MA, Gan M, McClintock TR, Volpe A, Borofsky MS, Mottrie A, et al. Near-infrared fluorescence imaging: emerging applications in robotic upper urinary tract surgery. Eur Urol. 2014;65:793–801. Clinical study demonstrating the initial surgical technique for NIRF imaging with ICG to facilitate selective arterial clamping along with additional applications in robotic urinary reconstruction. Short term outcomes demonstrated a median percent change in eGFR of 6.3%.CrossRefPubMed Bjurlin MA, Gan M, McClintock TR, Volpe A, Borofsky MS, Mottrie A, et al. Near-infrared fluorescence imaging: emerging applications in robotic upper urinary tract surgery. Eur Urol. 2014;65:793–801. Clinical study demonstrating the initial surgical technique for NIRF imaging with ICG to facilitate selective arterial clamping along with additional applications in robotic urinary reconstruction. Short term outcomes demonstrated a median percent change in eGFR of 6.3%.CrossRefPubMed
12.•
go back to reference McClintock TR, Bjurlin MA, Wysock JS, Borofsky MS, Marien TP, Okoro C, et al. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy? Urology. 2014;84:327–34. Matched-pair analysis of robotic partial nephrectomy with and without selective arterial clamping with NIRF and ICG. Selective clamping was associated with superior kidney function at discharge but this statistical difference was not observed at 3 months follow-up.CrossRefPubMed McClintock TR, Bjurlin MA, Wysock JS, Borofsky MS, Marien TP, Okoro C, et al. Can selective arterial clamping with fluorescence imaging preserve kidney function during robotic partial nephrectomy? Urology. 2014;84:327–34. Matched-pair analysis of robotic partial nephrectomy with and without selective arterial clamping with NIRF and ICG. Selective clamping was associated with superior kidney function at discharge but this statistical difference was not observed at 3 months follow-up.CrossRefPubMed
13.
go back to reference Piwkowski C, Gabryel P, Gasiorowski L, Zielinski P, Murawa D, Roszak M, et al. Indocyanine green fluorescence in the assessment of the quality of the pedicled intercostal muscle flap: a pilot study. Eur J Cardiothorac Surg. 2013;44(1):e77–81.CrossRefPubMed Piwkowski C, Gabryel P, Gasiorowski L, Zielinski P, Murawa D, Roszak M, et al. Indocyanine green fluorescence in the assessment of the quality of the pedicled intercostal muscle flap: a pilot study. Eur J Cardiothorac Surg. 2013;44(1):e77–81.CrossRefPubMed
14.
go back to reference Pacheco PE, Hill SM, Henriques SM, Paulsen JK, Anderson RC. The novel use of intraoperative laser-induced fluorescence of indocyanine green tissue angiography for evaluation of the gastric conduit in esophageal reconstructive surgery. Am J Surg. 2013;205:349–52. discussion 352–343.CrossRefPubMed Pacheco PE, Hill SM, Henriques SM, Paulsen JK, Anderson RC. The novel use of intraoperative laser-induced fluorescence of indocyanine green tissue angiography for evaluation of the gastric conduit in esophageal reconstructive surgery. Am J Surg. 2013;205:349–52. discussion 352–343.CrossRefPubMed
15.
go back to reference Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, et al. The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc. 2013;27(8):3003–8.CrossRefPubMed Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, et al. The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc. 2013;27(8):3003–8.CrossRefPubMed
16.
go back to reference Tobis S, Knopf J, Silvers C, Yao J, Rashid H, Wu G, et al. Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors. J Urol. 2011;186:47–52.CrossRefPubMed Tobis S, Knopf J, Silvers C, Yao J, Rashid H, Wu G, et al. Near infrared fluorescence imaging with robotic assisted laparoscopic partial nephrectomy: initial clinical experience for renal cortical tumors. J Urol. 2011;186:47–52.CrossRefPubMed
17.
go back to reference Tobis S, Knopf JK, Silvers C, Messing E, Yao J, Rashid H, et al. Robot-assisted and laparoscopic partial nephrectomy with near infrared fluorescence imaging. J Endourol. 2012;26:797–802.CrossRefPubMed Tobis S, Knopf JK, Silvers C, Messing E, Yao J, Rashid H, et al. Robot-assisted and laparoscopic partial nephrectomy with near infrared fluorescence imaging. J Endourol. 2012;26:797–802.CrossRefPubMed
18.
go back to reference Krane LS, Manny TB, Hemal AK. Is near infrared fluorescence imaging using indocyanine green dye useful in robotic partial nephrectomy: a prospective comparative study of 94 patients. Urology. 2012;80:110–6.CrossRefPubMed Krane LS, Manny TB, Hemal AK. Is near infrared fluorescence imaging using indocyanine green dye useful in robotic partial nephrectomy: a prospective comparative study of 94 patients. Urology. 2012;80:110–6.CrossRefPubMed
19.
go back to reference Golijanin DJMJ, Cardin A, Singer EA, Wood RW, Reeder JE, et al. Bilitranslocase (BTL) is immunolocalised in proximal and distal renal tubules and absent in renal cortical tumors accurately corresponding to intraoperative near infrared fluorescence (NIRF) expression of renal cortical tumors using intravenous INDOCYANINE GREEN (ICG). J Urol. 2008;179:137.CrossRef Golijanin DJMJ, Cardin A, Singer EA, Wood RW, Reeder JE, et al. Bilitranslocase (BTL) is immunolocalised in proximal and distal renal tubules and absent in renal cortical tumors accurately corresponding to intraoperative near infrared fluorescence (NIRF) expression of renal cortical tumors using intravenous INDOCYANINE GREEN (ICG). J Urol. 2008;179:137.CrossRef
20.
go back to reference Manny T, Krane LS, Hemal AK. Indocyanine green cannot predict malignancy in partial nephrectomy: histopathologic correlation with fluorescence pattern in 100 patients. J Endourol 2013;27:918–21. Manny T, Krane LS, Hemal AK. Indocyanine green cannot predict malignancy in partial nephrectomy: histopathologic correlation with fluorescence pattern in 100 patients. J Endourol 2013;27:918–21.
21.
go back to reference Phillips BT, Lanier ST, Conkling N, Wang ED, Dagum AB, Ganz JC, et al. Intraoperative perfusion techniques can accurately predict mastectomy skin flap necrosis in breast reconstruction: results of a prospective trial. Plast Reconstr Surg. 2012;129:778e–88.CrossRefPubMed Phillips BT, Lanier ST, Conkling N, Wang ED, Dagum AB, Ganz JC, et al. Intraoperative perfusion techniques can accurately predict mastectomy skin flap necrosis in breast reconstruction: results of a prospective trial. Plast Reconstr Surg. 2012;129:778e–88.CrossRefPubMed
22.•
go back to reference Borofsky MS, Gill IS, Hemal AK, Marien TP, Jayaratna I, Krane LS, et al. Near-infrared fluorescence imaging to facilitate super-selective arterial clamping during zero-ischaemia robotic partial nephrectomy. BJU Int 2013;111:604–10. First study to demonstrate the improvement in short term kidney function of robotic partial nephrectomy with selective arterial clamping using NIRF and ICG with only a 1.8% loss in eGFR compared to 14.9% in the main artery clamp cohort. Borofsky MS, Gill IS, Hemal AK, Marien TP, Jayaratna I, Krane LS, et al. Near-infrared fluorescence imaging to facilitate super-selective arterial clamping during zero-ischaemia robotic partial nephrectomy. BJU Int 2013;111:604–10. First study to demonstrate the improvement in short term kidney function of robotic partial nephrectomy with selective arterial clamping using NIRF and ICG with only a 1.8% loss in eGFR compared to 14.9% in the main artery clamp cohort.
24.
go back to reference Dulabon LM, Kaouk JH, Haber GP, Berkman DS, Rogers CG, Petros F, et al. Multi-institutional analysis of robotic partial nephrectomy for hilar versus nonhilar lesions in 446 consecutive cases. Eur Urol. 2011;59:325–30.CrossRefPubMed Dulabon LM, Kaouk JH, Haber GP, Berkman DS, Rogers CG, Petros F, et al. Multi-institutional analysis of robotic partial nephrectomy for hilar versus nonhilar lesions in 446 consecutive cases. Eur Urol. 2011;59:325–30.CrossRefPubMed
25.
go back to reference Mitsui Y, Shiina H, Arichi N, et al. Indocyanine green (ICG)-based fluorescence navigation system for discrimination of kidney cancer from normal parenchyma: application during partial nephrectomy. Int Urol Nephrol. 2012;44:753.CrossRefPubMed Mitsui Y, Shiina H, Arichi N, et al. Indocyanine green (ICG)-based fluorescence navigation system for discrimination of kidney cancer from normal parenchyma: application during partial nephrectomy. Int Urol Nephrol. 2012;44:753.CrossRefPubMed
26.
go back to reference Angell JE, Khemees TA, Abaza R. Optimization of near infrared fluorescence tumor localization during robotic partial nephrectomy. J Urol. 2013;190:1668–73.CrossRefPubMed Angell JE, Khemees TA, Abaza R. Optimization of near infrared fluorescence tumor localization during robotic partial nephrectomy. J Urol. 2013;190:1668–73.CrossRefPubMed
27.
go back to reference Harke N, Schoen G, Schiefelbein F, et al. Selective clamping under the usage of near-infrared fluorescence imaging with indocyanine green in robot-assisted partial nephrectomy: a single-surgeon matched-pair study. World J Urol. 2014;32:1259.CrossRefPubMed Harke N, Schoen G, Schiefelbein F, et al. Selective clamping under the usage of near-infrared fluorescence imaging with indocyanine green in robot-assisted partial nephrectomy: a single-surgeon matched-pair study. World J Urol. 2014;32:1259.CrossRefPubMed
28.
go back to reference Chapman D, Moore R, Klarenbach S, Braam B. Residual renal function after partial or radical nephrectomy for renal cell carcinoma. Can Urol Assoc J. 2010;4:337–43.PubMedCentralPubMed Chapman D, Moore R, Klarenbach S, Braam B. Residual renal function after partial or radical nephrectomy for renal cell carcinoma. Can Urol Assoc J. 2010;4:337–43.PubMedCentralPubMed
Metadata
Title
Near-Infrared Fluorescence Imaging with Intraoperative Administration of Indocyanine Green for Robotic Partial Nephrectomy
Authors
Marc A. Bjurlin
Tyler R. McClintock
Michael D. Stifelman
Publication date
01-04-2015
Publisher
Springer US
Published in
Current Urology Reports / Issue 4/2015
Print ISSN: 1527-2737
Electronic ISSN: 1534-6285
DOI
https://doi.org/10.1007/s11934-015-0495-9

Other articles of this Issue 4/2015

Current Urology Reports 4/2015 Go to the issue

New Imaging Techniques (A Rastinehad and S Rais-Bahrami, Section Editors)

Contemporary Assessment of Renal Stone Complexity Using Cross-Sectional Imaging

Prostate Cancer (A Kibel, Section Editor)

Active Surveillance for Low-Risk Prostate Cancer

New Imaging Techniques (A Rastinehad and S Rais-Bahrami, Section Editors)

Post Partial Nephrectomy Surveillance Imaging: an Evidence-Based Approach

New Imaging Techniques (A Rastinehad and S Rais-Bahrami, Section Editors)

Preoperative Imaging for Staging Bladder Cancer