Skip to main content
Top
Published in: Clinical Oral Investigations 2/2016

01-03-2016 | Original Article

Multibracket appliance: impression defaults and their reduction by blocking-out  —  a three-dimensional study

Authors: Susanne Wriedt, Moritz Foersch, Jan Daniel Muhle, Irene Schmidtmann, Heinrich Wehrbein

Published in: Clinical Oral Investigations | Issue 2/2016

Login to get access

Abstract

Objectives

This study examines accuracy of dental impressions and following plaster models taken during treatment with fixed appliances.

Materials and methods

A maxillary typodont was provided with brackets. Three examiners took impressions three times each of the variants: brackets only, archwire fixed by alastics, ligatures or Kobayashi-hooks, and brackets and archwire covered completely or just on the gingival side by protection or impression wax. Casts were scanned using Activity102®. Virtual models were compared to the scan of the typodont using Comparison®. Differences were measured and descriptively analyzed. Estimated means with 95 % confidence intervals were computed. Significance was assessed using linear mixed models.

Results

While pyramidal reference blocks had a mean difference of 0.019 mm (95 % CI = 0.017–0.021 mm) to the master model, teeth without attachments showed 0.097 mm (95 % CI = 0.082–0.111 mm), and teeth with brackets 0.169 mm (95 % CI = 0.156–0.182 mm) (p < 0.001). Smallest mean was found when using protection wax only on the gingival bracket side (0.152 mm (95 % CI = 0.113–0.192 mm)). Incisors deviated most (0.258 mm (95 % CI = 0.239–0.277 mm)).

Conclusions

Teeth with brackets make impressions more inaccurate because of undercuts. Removing the archwire before taking the impression or covering the brackets on the gingival side shows tendencies toward better precision.

Clinical relevance

Taking impressions during treatment with fixed appliances, some inaccuracy has to be taken into account.
Literature
4.
go back to reference Taylor RL, Wright PS, Maryan C (2002) Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater 18(2):103–110CrossRefPubMed Taylor RL, Wright PS, Maryan C (2002) Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater 18(2):103–110CrossRefPubMed
6.
go back to reference Ayoub AF, Wray D, Moos KF, Jin J, Niblett TB, Urquhart C, Mowforth P, Siebert P (1997) A three-dimensional imaging system for archiving dental study casts: a preliminary report. Int J Adult Orthodon Orthognath Surg 12(1):79–84PubMed Ayoub AF, Wray D, Moos KF, Jin J, Niblett TB, Urquhart C, Mowforth P, Siebert P (1997) A three-dimensional imaging system for archiving dental study casts: a preliminary report. Int J Adult Orthodon Orthognath Surg 12(1):79–84PubMed
8.
go back to reference Ryden H, Bjelkhagen H, Martensson B (1982) Tooth position measurements on dental casts using holographic images. Am J Orthod 81(4):310–313CrossRefPubMed Ryden H, Bjelkhagen H, Martensson B (1982) Tooth position measurements on dental casts using holographic images. Am J Orthod 81(4):310–313CrossRefPubMed
10.
go back to reference Trefny P, Smahel Z, Formanek P, Peterka M (2004) Three-dimensional analysis of maxillary dental casts using fourier transform profilometry: precision and reliability of the measurement. Cleft Palate Craniofac J 41(1):20–26. doi:10.1597/02-097 CrossRefPubMed Trefny P, Smahel Z, Formanek P, Peterka M (2004) Three-dimensional analysis of maxillary dental casts using fourier transform profilometry: precision and reliability of the measurement. Cleft Palate Craniofac J 41(1):20–26. doi:10.​1597/​02-097 CrossRefPubMed
13.
go back to reference Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ (2009) Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 136(1):16 e11–16 e14 discussion 16. doi:10.1016/j.ajodo.2008.11.019 Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ (2009) Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 136(1):16 e11–16 e14 discussion 16. doi:10.​1016/​j.​ajodo.​2008.​11.​019
14.
go back to reference Wiranto MG, Engelbrecht WP, Tutein Nolthenius HE, van der Meer WJ, Ren Y (2013) Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod DentofacOrthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 143(1):140–147. doi:10.1016/j.ajodo.2012.06.018 Wiranto MG, Engelbrecht WP, Tutein Nolthenius HE, van der Meer WJ, Ren Y (2013) Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod DentofacOrthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 143(1):140–147. doi:10.​1016/​j.​ajodo.​2012.​06.​018
17.
go back to reference Mullen SR, Martin CA, Ngan P, Gladwin M (2007) Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 132(3):346–352. doi:10.1016/j.ajodo.2005.08.044 Mullen SR, Martin CA, Ngan P, Gladwin M (2007) Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 132(3):346–352. doi:10.​1016/​j.​ajodo.​2005.​08.​044
18.
go back to reference Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 124(1):101–105. doi:10.1016/S0889540603001525 Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 124(1):101–105. doi:10.​1016/​S088954060300152​5
19.
go back to reference Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 129(6):794–803. doi:10.1016/j.ajodo.2004.08.023 Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 129(6):794–803. doi:10.​1016/​j.​ajodo.​2004.​08.​023
20.
go back to reference Wriedt S, Schmidtmann I, Niemann M, Wehrbein H (2013) Digital 3D image of bimaxillary casts connected by a vestibular scan. J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 74(4):309–318. doi:10.1007/s00056-013-0152-1 CrossRef Wriedt S, Schmidtmann I, Niemann M, Wehrbein H (2013) Digital 3D image of bimaxillary casts connected by a vestibular scan. J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 74(4):309–318. doi:10.​1007/​s00056-013-0152-1 CrossRef
21.
go back to reference DeLong R, Heinzen M, Hodges JS, Ko CC, Douglas WH (2003) Accuracy of a system for creating 3D computer models of dental arches. J Dent Res 82(6):438–442CrossRefPubMed DeLong R, Heinzen M, Hodges JS, Ko CC, Douglas WH (2003) Accuracy of a system for creating 3D computer models of dental arches. J Dent Res 82(6):438–442CrossRefPubMed
23.
go back to reference Asquith JA, McIntyre GT (2012) Dental arch relationships on three-dimensional digital study models and conventional plaster study models for patients with unilateral cleft lip and palate. Cleft Palate Craniofac J 49(5):530–534. doi:10.1597/10-099 CrossRefPubMed Asquith JA, McIntyre GT (2012) Dental arch relationships on three-dimensional digital study models and conventional plaster study models for patients with unilateral cleft lip and palate. Cleft Palate Craniofac J 49(5):530–534. doi:10.​1597/​10-099 CrossRefPubMed
26.
go back to reference Braumann B, Rosenhayn SE, Bourauel C, Jäger A (2001) Two- or three-dimensional cast analysis in patients with cleft lip and palate? J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 62(6):451–465CrossRef Braumann B, Rosenhayn SE, Bourauel C, Jäger A (2001) Two- or three-dimensional cast analysis in patients with cleft lip and palate? J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 62(6):451–465CrossRef
27.
go back to reference Boldt F, Weinzierl C, Hertrich K, Hirschfelder U (2009) Comparison of the spatial landmark scatter of various 3D digitalization methods. J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 70(3):247–263. doi:10.1007/s00056-009-0902-2 CrossRef Boldt F, Weinzierl C, Hertrich K, Hirschfelder U (2009) Comparison of the spatial landmark scatter of various 3D digitalization methods. J Orofac Orthop Fortschr Kieferorthop Organ/Off J Deut Ges Kieferorthop 70(3):247–263. doi:10.​1007/​s00056-009-0902-2 CrossRef
28.
go back to reference Craig RG (1988) Review of dental impression materials. Adv Dent Res 2(1):51–64PubMed Craig RG (1988) Review of dental impression materials. Adv Dent Res 2(1):51–64PubMed
29.
go back to reference Peters MC, Tieleman A (1992) Accuracy and dimensional stability of a combined hydrocolloid impression system. J Prosthet Dent 67(6):873–878CrossRefPubMed Peters MC, Tieleman A (1992) Accuracy and dimensional stability of a combined hydrocolloid impression system. J Prosthet Dent 67(6):873–878CrossRefPubMed
30.
31.
go back to reference Cohen BI, Pagnillo M, Deutsch AS, Musikant BL (1995) Dimensional accuracy of three different alginate impression materials. J Prosthodont 4(3):195–199CrossRefPubMed Cohen BI, Pagnillo M, Deutsch AS, Musikant BL (1995) Dimensional accuracy of three different alginate impression materials. J Prosthodont 4(3):195–199CrossRefPubMed
32.
go back to reference Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A (2012) Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 142(2):269–273. doi:10.1016/j.ajodo.2011.12.028 Sousa MV, Vasconcelos EC, Janson G, Garib D, Pinzan A (2012) Accuracy and reproducibility of 3-dimensional digital model measurements. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 142(2):269–273. doi:10.​1016/​j.​ajodo.​2011.​12.​028
33.
go back to reference Wada K (1992) Studies on dimensional accuracy of working casts made by various impression techniques—influence of undercuts on dimensional accuracy. Kokubyo Gakkai Zasshi 59(2):518–540CrossRefPubMed Wada K (1992) Studies on dimensional accuracy of working casts made by various impression techniques—influence of undercuts on dimensional accuracy. Kokubyo Gakkai Zasshi 59(2):518–540CrossRefPubMed
34.
go back to reference Grünheid T, McCarthy SD, Larson BE (2014) Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 146(5):673–682. doi:10.1016/j.ajodo.2014.07.023 Grünheid T, McCarthy SD, Larson BE (2014) Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance. Am J Orthod Dentofac Orthop Off Publ Am Assoc Orthod Constituent Soc Am Board Orthod 146(5):673–682. doi:10.​1016/​j.​ajodo.​2014.​07.​023
Metadata
Title
Multibracket appliance: impression defaults and their reduction by blocking-out  —  a three-dimensional study
Authors
Susanne Wriedt
Moritz Foersch
Jan Daniel Muhle
Irene Schmidtmann
Heinrich Wehrbein
Publication date
01-03-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 2/2016
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1514-4

Other articles of this Issue 2/2016

Clinical Oral Investigations 2/2016 Go to the issue