Skip to main content
Top
Published in: European Spine Journal 1/2012

01-01-2012 | Chinese section

Modified technique for C1–2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft

Authors: Bin Ni, Fengjin Zhou, Qunfeng Guo, Songkai Li, Xiang Guo, Ning Xie

Published in: European Spine Journal | Issue 1/2012

Login to get access

Abstract

Introduction

Various techniques have been described for posterior atlantoaxial fusion. Sublaminar passage of the wire/cable is cumbersome with a risk of spinal cord injury. Packing morselized bone grafts into the C1–2 facet joints may be difficult and it may cause massive bleeding and neuropathic pain or posterior scalp numbness postoperatively. We introduce a modified method by using C1–2 screw-rod fixation (SRF) to compress a structural iliac bone graft between the posterior elements of C1 and C2 without supplemental wiring construct.

Materials and methods

From December 2006 to May 2009, 35 consecutive patients with atlantoaxial instability treated by this method were reviewed retrospectively. Clinical and radiographic history was recorded. Patients with neck pain had relieved significantly after surgery and the neurologic status was also improved greatly. Thirty-three (94.3%) patients gained bony fusion at 3 months postoperatively. No vertebral artery and spinal cord injuries were noted. There was no instrumentation failure during the observation period.

Conclusion

We conclude that the C1–2 SRF with construct–compression structural bone grafting can be used for C1–2 fusion with relatively simple performance and less time-consuming in selected cases.
Literature
2.
go back to reference Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129:47–53CrossRef Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129:47–53CrossRef
3.
go back to reference Harms J, Melcher RP (2001) Posterior C1–2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef Harms J, Melcher RP (2001) Posterior C1–2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471CrossRef
4.
go back to reference Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 5:464–475PubMedCrossRef Jeanneret B, Magerl F (1992) Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord 5:464–475PubMedCrossRef
6.
go back to reference Resnick DK, Benzel EC (2002) C1–2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery 50:426–428PubMed Resnick DK, Benzel EC (2002) C1–2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery 50:426–428PubMed
7.
go back to reference Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351–1356 discussion 1356–1357PubMed Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351–1356 discussion 1356–1357PubMed
8.
13.
go back to reference Kuroki H, Rengachary SS, Goel VK, Holekamp SA, Pitkanen V, Ebraheim NA (2005) Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 56:151–159 discussion 151–159PubMedCrossRef Kuroki H, Rengachary SS, Goel VK, Holekamp SA, Pitkanen V, Ebraheim NA (2005) Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 56:151–159 discussion 151–159PubMedCrossRef
15.
19.
go back to reference Nojiri K, Matsumoto M, Chiba K, Maruiwa H, Nakamura M, Nishizawa T, Toyama Y (2003) Relationship between alignment of upper and lower cervical spine in asymptomatic individuals. J Neurosurg 99:80–83PubMedCrossRef Nojiri K, Matsumoto M, Chiba K, Maruiwa H, Nakamura M, Nishizawa T, Toyama Y (2003) Relationship between alignment of upper and lower cervical spine in asymptomatic individuals. J Neurosurg 99:80–83PubMedCrossRef
20.
go back to reference Aryan HE, Newman CB, Nottmeier EW, Acosta FL Jr, Wang VY, Ames CP (2008) Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229. doi:10.3171/SPI/2008/8/3/222 PubMedCrossRef Aryan HE, Newman CB, Nottmeier EW, Acosta FL Jr, Wang VY, Ames CP (2008) Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229. doi:10.​3171/​SPI/​2008/​8/​3/​222 PubMedCrossRef
21.
go back to reference Lee SH, Kim ES, Sung JK, Park YM, Eoh W (2010) Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1–2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. J Clin Neurosci 17:886–892. doi:10.1016/j.jocn.2009.10.008 PubMedCrossRef Lee SH, Kim ES, Sung JK, Park YM, Eoh W (2010) Clinical and radiological comparison of treatment of atlantoaxial instability by posterior C1–2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation. J Clin Neurosci 17:886–892. doi:10.​1016/​j.​jocn.​2009.​10.​008 PubMedCrossRef
24.
go back to reference Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Xiang M, Zhao WD, Zhong SZ (2009) C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine (Phila Pa 1976) 34:371–377. doi:10.1097/BRS.0b013e318193a21b CrossRef Ma XY, Yin QS, Wu ZH, Xia H, Liu JF, Xiang M, Zhao WD, Zhong SZ (2009) C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities. Spine (Phila Pa 1976) 34:371–377. doi:10.​1097/​BRS.​0b013e318193a21b​ CrossRef
Metadata
Title
Modified technique for C1–2 screw-rod fixation and fusion using autogenous bicortical iliac crest graft
Authors
Bin Ni
Fengjin Zhou
Qunfeng Guo
Songkai Li
Xiang Guo
Ning Xie
Publication date
01-01-2012
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue 1/2012
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-011-1958-4

Other articles of this Issue 1/2012

European Spine Journal 1/2012 Go to the issue