Abstract

The advent of modern MRI scanners and computer equipment permits the rapid sequential collection of images of gadolinium chelate (Gd) transit through the kidney. The excellent spatial and temporal (0.9 s) resolution permits analyzing the shape of the recovered curves with a sophisticated model that includes both space and time. The purpose of this manuscript is to present such a mathematical model. By building into the model significant physical processes that contribute to the shape of the measured curve, quantitative values can be assigned to important parameters.
In this work, quantitative values are determined for blood dispersion through the cardio-pulmonary system, systemic clearance rate of Gd, blood flow into each kidney, blood transit time in each kidney, the extraction rate of Gd across the capillary membrane, interstitial distribution volume, and the GFR for each kidney.
Literature
1.
go back to reference Holechek MJ (2003) Glomerular filtration: an overview. Nephrol Nurs J 30:285–290; quiz 291–292PubMed Holechek MJ (2003) Glomerular filtration: an overview. Nephrol Nurs J 30:285–290; quiz 291–292PubMed
2.
go back to reference McDaniel BB, Jones RA, Scherz H et al (2005) Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: part 2, anatomic and functional assessment of uteropelvic junction obstruction. AJR 185:1608–1614PubMedCrossRef McDaniel BB, Jones RA, Scherz H et al (2005) Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: part 2, anatomic and functional assessment of uteropelvic junction obstruction. AJR 185:1608–1614PubMedCrossRef
3.
go back to reference Jones RA, Easley K, Little SB et al (2005) Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: part 1, functional assessment. AJR 185:1598–1607PubMedCrossRef Jones RA, Easley K, Little SB et al (2005) Dynamic contrast-enhanced MR urography in the evaluation of pediatric hydronephrosis: part 1, functional assessment. AJR 185:1598–1607PubMedCrossRef
4.
go back to reference Huang AJ, Lee VS, Rusinek H (2004) Functional renal MR imaging. Magn Reson Imaging Clin N Am 12:469–486, viPubMedCrossRef Huang AJ, Lee VS, Rusinek H (2004) Functional renal MR imaging. Magn Reson Imaging Clin N Am 12:469–486, viPubMedCrossRef
5.
go back to reference Lee VS, Rusinek H, Noz ME et al (2003) Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience. Radiology 227:289–294PubMedCrossRef Lee VS, Rusinek H, Noz ME et al (2003) Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience. Radiology 227:289–294PubMedCrossRef
6.
go back to reference Niendorf ER, Grist TM, Frayne R et al (1997) Rapid measurement of Gd-DTPA extraction fraction in a dialysis system using echo-planar imaging. Med Phys 24:1907–1913PubMedCrossRef Niendorf ER, Grist TM, Frayne R et al (1997) Rapid measurement of Gd-DTPA extraction fraction in a dialysis system using echo-planar imaging. Med Phys 24:1907–1913PubMedCrossRef
7.
go back to reference Hackstein N, Heckrodt J, Rau WS (2003) Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique. J Magn Reson Imaging 18:714–725PubMedCrossRef Hackstein N, Heckrodt J, Rau WS (2003) Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique. J Magn Reson Imaging 18:714–725PubMedCrossRef
8.
go back to reference Hackstein N, Kooijman H, Tomaselli S et al (2005) Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of Gd-DTPA. J Magn Reson Imaging 22:406–414PubMedCrossRef Hackstein N, Kooijman H, Tomaselli S et al (2005) Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of Gd-DTPA. J Magn Reson Imaging 22:406–414PubMedCrossRef
9.
go back to reference Park JB, Santos JM, Hargreaves BA et al (2005) Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI. J Magn Reson Imaging 21:590–595PubMedCrossRef Park JB, Santos JM, Hargreaves BA et al (2005) Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI. J Magn Reson Imaging 21:590–595PubMedCrossRef
10.
go back to reference Bax L, Bakker CJ, Klein WM et al (2005) Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: normal values and reproducibility. J Vasc Interv Radiol 16:807–814PubMed Bax L, Bakker CJ, Klein WM et al (2005) Renal blood flow measurements with use of phase-contrast magnetic resonance imaging: normal values and reproducibility. J Vasc Interv Radiol 16:807–814PubMed
11.
go back to reference Thompson RB, McVeigh ER (2004) Flow-gated phase-contrast MRI using radial acquisitions. Magn Reson Med 52:598–604PubMedCrossRef Thompson RB, McVeigh ER (2004) Flow-gated phase-contrast MRI using radial acquisitions. Magn Reson Med 52:598–604PubMedCrossRef
12.
go back to reference de Haan MW, van Engelshoven JM, Houben AJ et al (2003) Phase-contrast magnetic resonance flow quantification in renal arteries: comparison with 133Xenon washout measurements. Hypertension 41:114–118PubMedCrossRef de Haan MW, van Engelshoven JM, Houben AJ et al (2003) Phase-contrast magnetic resonance flow quantification in renal arteries: comparison with 133Xenon washout measurements. Hypertension 41:114–118PubMedCrossRef
13.
go back to reference Thompson HK Jr, Starmer CF, Whalen RE et al (1964) Indicator transit time considered as a gamma variate. Circ Res 14:502–515PubMed Thompson HK Jr, Starmer CF, Whalen RE et al (1964) Indicator transit time considered as a gamma variate. Circ Res 14:502–515PubMed
14.
go back to reference Harpen MD, Lecklitner ML (1984) Derivation of gamma variate indicator dilution function from simple convective dispersion model of blood flow. Med Phys 11:690–692PubMedCrossRef Harpen MD, Lecklitner ML (1984) Derivation of gamma variate indicator dilution function from simple convective dispersion model of blood flow. Med Phys 11:690–692PubMedCrossRef
15.
go back to reference Press W, Flannery B, Teukolsky S et al (1988) Numerical recipes in C. The art of scientific computing. Cambridge University Press, New York Press W, Flannery B, Teukolsky S et al (1988) Numerical recipes in C. The art of scientific computing. Cambridge University Press, New York
16.
go back to reference Patlak CS, Blasberg RG (1985) Graphical evaluation of blood-to-brain transfer constant from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab 5:584–590PubMed Patlak CS, Blasberg RG (1985) Graphical evaluation of blood-to-brain transfer constant from multiple-time uptake data. Generalizations. J Cereb Blood Flow Metab 5:584–590PubMed
17.
go back to reference Patlak CS, Blasberg RG, Fenstermacher JD (1983) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 3:1–7PubMed Patlak CS, Blasberg RG, Fenstermacher JD (1983) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 3:1–7PubMed
Metadata
Title
Modeling systemic and renal gadolinium chelate transport with MRI
Authors
John R. Votaw
Diego Martin
Publication date
01-01-2008
Publisher
Springer-Verlag
Published in
Pediatric Radiology / Issue Special Issue 1/2008
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-007-0588-9

Other articles of this Special Issue 1/2008

Pediatric Radiology 1/2008 Go to the issue