Published in: Clinical Oral Investigations 1/2005

01-03-2005 | Original Article

Methods for measuring agreement: glucose levels in gingival crevice blood

Authors: Hans-Peter Müller, Ebrahim Behbehani

Published in: Clinical Oral Investigations | Issue 1/2005

Login to get access

Abstract

The aim of the present study was to compare conclusions drawn by two different methods for comparison of blood glucose determination in capillary fingerstick blood (CFB) and gingival crevice blood (GCB). Glucose levels in CFB and GCB oozing from the gingiva after periodontal probing were measured in 31 patients with gingivitis or periodontitis using a novel, very sensitive self-monitoring device (Freestyle, TheraSense Inc.) developed for off-finger tip glucose testing. Correlation analysis revealed that measurements of glucose levels in CFB from left and right finger tips were highly correlated pointing to excellent performance of the device, whereas CFB and GCB measurements were moderately, but highly significantly, correlated. A thorough analysis of agreement revealed, on the other hand, questionable performance of the device for screening hypoglycaemic patients. The mean difference of measurements in CFB samples was +3.2±12.7 mg/dl. The 95% limits of agreement were −21.7 and +28.2. The mean difference of glucose determination in CFB and GCB samples was −22.0±26.6 mg/dl, and limits of agreement were −74.4 and +30.1. By plotting differences on means of measurements and doing linear regression analysis no systematic trend of change in differences with increasing mean of measurements was ascertained. Analysis of agreement revealed that performance of the Freestyle measuring device yielded considerably large limits of agreement, and gingival crevice blood cannot be recommended for measuring blood glucose levels.
Literature
1.
go back to reference Beikler T, Kuczek A, Petersilka G, Flemmig TF (2002) In-dental-office screening for diabetes mellitus using gingival crevicular blood. J Clin Periodontol 29:216–218PubMed Beikler T, Kuczek A, Petersilka G, Flemmig TF (2002) In-dental-office screening for diabetes mellitus using gingival crevicular blood. J Clin Periodontol 29:216–218PubMed
2.
go back to reference Bland JM, Altman DG (1986) Comparing methods for assessing agreement between two methods of clinical measurement. Lancet i:307–310 Bland JM, Altman DG (1986) Comparing methods for assessing agreement between two methods of clinical measurement. Lancet i:307–310
3.
go back to reference Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160PubMed Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160PubMed
4.
go back to reference Clarke WL, Cox D, Gender-Frederick LA, Cater W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10:622–628PubMed Clarke WL, Cox D, Gender-Frederick LA, Cater W, Pohl SL (1987) Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 10:622–628PubMed
5.
go back to reference Feldman B, McGarraugh G, Heller A, Bohannon N, Skyler J, DeLeeuw E, Clarke D (2000) FreeStyle: a small-volume electrochemical glucose sensor for home blood glucose testing. Diabetes Technol Ther 2:221–229 Feldman B, McGarraugh G, Heller A, Bohannon N, Skyler J, DeLeeuw E, Clarke D (2000) FreeStyle: a small-volume electrochemical glucose sensor for home blood glucose testing. Diabetes Technol Ther 2:221–229
6.
go back to reference Fleiss JL (1986) Reliability of measurement. In: Fleiss JL (ed) The design and analysis of clinical experiments. Wiley, New York, pp 1–32 Fleiss JL (1986) Reliability of measurement. In: Fleiss JL (ed) The design and analysis of clinical experiments. Wiley, New York, pp 1–32
7.
go back to reference Koran LM (1975) The reliability of clinical methods, data and judgements (first of two parts). N Engl J Med 293:642–646PubMed Koran LM (1975) The reliability of clinical methods, data and judgements (first of two parts). N Engl J Med 293:642–646PubMed
8.
go back to reference Koran LM (1975) The reliability of clinical methods, data and judgements (second of two parts). N Engl J Med 293:695–701PubMed Koran LM (1975) The reliability of clinical methods, data and judgements (second of two parts). N Engl J Med 293:695–701PubMed
9.
go back to reference Lee DM, Weinert SE, Miller EE (2002) A study of forearm versus finger stick glucose monitoring. Diabetes Technol Ther 4:13–23PubMed Lee DM, Weinert SE, Miller EE (2002) A study of forearm versus finger stick glucose monitoring. Diabetes Technol Ther 4:13–23PubMed
11.
go back to reference McGarraugh G, Price D, Schwartz S, Weinstein R (2001) Physiological influences on off-finger glucose testing. Diabetes Technol Ther 3:367–376PubMed McGarraugh G, Price D, Schwartz S, Weinstein R (2001) Physiological influences on off-finger glucose testing. Diabetes Technol Ther 3:367–376PubMed
12.
go back to reference Mealey B (2000) Diabetes and periodontal disease. J Periodontol 71:664–678PubMed Mealey B (2000) Diabetes and periodontal disease. J Periodontol 71:664–678PubMed
13.
go back to reference Müller HP, Behbehani E (2004) Screening of elevated glucose levels in gingival crevice blood using a novel, sensitive self-monitoring device. Med Princ Pract 13:361–365CrossRefPubMed Müller HP, Behbehani E (2004) Screening of elevated glucose levels in gingival crevice blood using a novel, sensitive self-monitoring device. Med Princ Pract 13:361–365CrossRefPubMed
14.
go back to reference Parker RC, Rapley JW, Isley W, Spencer P, Killoy WJ (1993) Gingival crevicular blood for assessment of blood glucose in diabetic patients. J Periodontol 64:666–672PubMed Parker RC, Rapley JW, Isley W, Spencer P, Killoy WJ (1993) Gingival crevicular blood for assessment of blood glucose in diabetic patients. J Periodontol 64:666–672PubMed
15.
go back to reference Stöckl D, Dewitte K, Fierens C, Thienpont LM (2000) Evaluating clinical accuracy of systems for self-monitoring of blood glucose by error grid analysis: comment on constructing the “upper A-line”. Diabetes Care 23:1711PubMed Stöckl D, Dewitte K, Fierens C, Thienpont LM (2000) Evaluating clinical accuracy of systems for self-monitoring of blood glucose by error grid analysis: comment on constructing the “upper A-line”. Diabetes Care 23:1711PubMed
Metadata
Title
Methods for measuring agreement: glucose levels in gingival crevice blood
Authors
Hans-Peter Müller
Ebrahim Behbehani
Publication date
01-03-2005
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 1/2005
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-004-0290-3

Other articles of this Issue 1/2005

Clinical Oral Investigations 1/2005 Go to the issue

Calendar of Events

Calendar of events