Skip to main content
Top
Published in: Journal of Medical Case Reports 1/2016

Open Access 01-12-2016 | Case report

Mechanical aortic valve without anticoagulation for 33 years in a Yemeni man: a case report

Author: Khadija Aman

Published in: Journal of Medical Case Reports | Issue 1/2016

Login to get access

Abstract

Background

Mechanical prosthetic heart valves have been used for many decades to replace damaged native valves. Guidelines mandate the use of anticoagulant therapy in patients with mechanical prosthetic valves of any type, irrespective of the position in the heart. The rationale for this is to prevent valve thrombosis and thromboembolic complications without increasing the risk of excess bleeding. We report a case involving a patient with a functioning aortic mechanical valve without any anticoagulation therapy for 33 years.

Case presentation

A 46-year-old Yemeni man had an aortic valve replacement, using a St Jude Medical mechanical valve, 33 years ago due to aortic regurgitation grade III–IV of his native valve as a result of rheumatic heart disease. His anticoagulant therapy of Syncumar (acenocoumarol which is a derivative of coumarin) was discontinued 4 months after surgery, and he was sustained on aspirin and digoxin. He presented to our cardiac clinic 33 years later with palpitations, which had started 2 weeks previously. On clinical examination, his condition was fair with a New York Heart Association functional classification of I. He was in sinus rhythm and had normal heart size, as shown on chest X-ray. Echocardiography revealed normal heart chamber dimensions and normal left ventricular systolic and diastolic function. His mean transaortic gradient was 12.58 mmHg and the calculated aortic valve area was 1.44 cm2. He was started on anticoagulant therapy.

Conclusions

Only a few cases of well-functioning mechanical valves without the use of anticoagulant therapy for many years have been reported. Our patient is one such case who used only aspirin for 33 years. Further research is needed to understand the interpersonal variations and other unexplored factors in anticoagulant therapy for patients with mechanical prosthetic heart valves.
Literature
2.
go back to reference Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin 3rd JP, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Thorac Cardiovasc Surg. 2014;148(1):e1–132.CrossRefPubMed Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin 3rd JP, Guyton RA, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Thorac Cardiovasc Surg. 2014;148(1):e1–132.CrossRefPubMed
4.
go back to reference Butchart EG. Antithrombotic management in patients with prosthetic valves: a comparison of American and European guidelines. Heart. 2009;95(5):430–6.CrossRefPubMed Butchart EG. Antithrombotic management in patients with prosthetic valves: a comparison of American and European guidelines. Heart. 2009;95(5):430–6.CrossRefPubMed
5.
go back to reference Torella M, Torella D, Nappi G, Chiodini P, Torella M, De Santo LS. Oral anticoagulation after mechanical heart valve replacement: low intensity regimen can make the difference. J Clin Exp Cardiol. 2014;5:319. doi:10.4172/2155-9880.1000319. Torella M, Torella D, Nappi G, Chiodini P, Torella M, De Santo LS. Oral anticoagulation after mechanical heart valve replacement: low intensity regimen can make the difference. J Clin Exp Cardiol. 2014;5:319. doi:10.​4172/​2155-9880.​1000319.
6.
go back to reference Ikizler M, Birdane A, Sevin B. An old friend is still at work: 34-year-old well functioning Starr-Edwards aortic prosthesis without anticoagulation. Int J Cardiol. 2007;116(1):e1–3.CrossRefPubMed Ikizler M, Birdane A, Sevin B. An old friend is still at work: 34-year-old well functioning Starr-Edwards aortic prosthesis without anticoagulation. Int J Cardiol. 2007;116(1):e1–3.CrossRefPubMed
7.
go back to reference Sharma S, McMurty K, Chalapathy N, Ameen A. Mechanical aortic valve without anticoagulation for twenty-three years. Interact Cardiovasc Thorac Surg. 2009;8(2):263–4.CrossRefPubMed Sharma S, McMurty K, Chalapathy N, Ameen A. Mechanical aortic valve without anticoagulation for twenty-three years. Interact Cardiovasc Thorac Surg. 2009;8(2):263–4.CrossRefPubMed
8.
go back to reference Yildiz A, Ozcan F, Dogan M, Ozlu MF, Sasmaz A. Twenty-two years without anticoagulation with metallic heart valve. J Natl Med Assoc. 2006;98(8):1348–9.PubMedPubMedCentral Yildiz A, Ozcan F, Dogan M, Ozlu MF, Sasmaz A. Twenty-two years without anticoagulation with metallic heart valve. J Natl Med Assoc. 2006;98(8):1348–9.PubMedPubMedCentral
9.
go back to reference Iscan HZ, Seren M, Kucukaksu DS, Bayazit K. Mechanical heart valve prosthesis in the pulmonary position without anticoagulation: case report. J Heart Valve Dis. 2004;13(1):149–51.PubMed Iscan HZ, Seren M, Kucukaksu DS, Bayazit K. Mechanical heart valve prosthesis in the pulmonary position without anticoagulation: case report. J Heart Valve Dis. 2004;13(1):149–51.PubMed
10.
go back to reference Emery RW, Krogh CC, Arom KV, Emery AM, Benyo-Albrecht K, Joyce LD, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement. Ann Thorac Surg. 2005;79(3):776–82. discussion 782-773.CrossRefPubMed Emery RW, Krogh CC, Arom KV, Emery AM, Benyo-Albrecht K, Joyce LD, et al. The St. Jude Medical cardiac valve prosthesis: a 25-year experience with single valve replacement. Ann Thorac Surg. 2005;79(3):776–82. discussion 782-773.CrossRefPubMed
11.
go back to reference Yoganathan AP, He Z, Casey Jones S. Fluid mechanics of heart valves. Annu Rev Biomed Eng. 2004;6:331–62.CrossRefPubMed Yoganathan AP, He Z, Casey Jones S. Fluid mechanics of heart valves. Annu Rev Biomed Eng. 2004;6:331–62.CrossRefPubMed
13.
go back to reference Weinstein GS, Mavroudis C, Ebert PA. Preliminary experience with aspirin for anticoagulation in children with prosthetic cardiac valves. Ann Thorac Surg. 1982;33(6):549–53.CrossRefPubMed Weinstein GS, Mavroudis C, Ebert PA. Preliminary experience with aspirin for anticoagulation in children with prosthetic cardiac valves. Ann Thorac Surg. 1982;33(6):549–53.CrossRefPubMed
14.
go back to reference Pass HI, Sade RM, Crawford FA, Hohn AR. Cardiac valve prostheses in children without anticoagulation. J Thorac Cardiovasc Surg. 1984;87(6):832–5.PubMed Pass HI, Sade RM, Crawford FA, Hohn AR. Cardiac valve prostheses in children without anticoagulation. J Thorac Cardiovasc Surg. 1984;87(6):832–5.PubMed
Metadata
Title
Mechanical aortic valve without anticoagulation for 33 years in a Yemeni man: a case report
Author
Khadija Aman
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2016
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-016-0976-6

Other articles of this Issue 1/2016

Journal of Medical Case Reports 1/2016 Go to the issue