Measurements of the contact force from myenteric contractions on a solid bolus

Authors: Benjamin S. Terry, Jonathan A. Schoen, Mark E. Rentschler

Published in: Journal of Robotic Surgery | Issue 1/2013

Login to get access

Abstract

The development of robotic capsule endoscopes (RCEs) is one avenue presently investigated by multiple research groups to minimize invasiveness and enhance outcomes of enteroscopic procedures. Understanding the biomechanical response of the small bowel to RCEs is needed for design optimization of these devices. In previous work, the authors developed, characterized, and tested the migrating motor complex force sensor (MFS), a novel sensor for quantifying the contact forces per unit of axial length exerted by the myenteron on a solid bolus. This work is a continuation, in which the MFS is used to quantify the contractile strength in the small intestine proximal, middle, and distal regions of five live porcine models. The MFSs are surgically implanted in a generally anesthetized animal, and force data from 5 min of dwell time are analyzed. The mean myenteric contact force from all porcine models and locations within the bowel is 1.9 ± 1.0 N cm−1. Examining the results based on the small bowel region shows a statistically significant strengthening trend in the contractile force from proximal to middle to distal with mean forces of 1.2 ± 0.5, 1.9 ± 0.9, and 2.3 ± 1.0 N cm−1, respectively (mean ± one standard deviation). Quantification of the contact force against a solid bolus provides developers of RCEs with a valuable, experimentally derived parameter of the intraluminal environment.
Literature
1.
go back to reference Leighton JA, Legnani P, Seidman EG (2007) Role of capsule endoscopy in inflammatory bowel disease: where we are and where we are going. Inflamm Bowel Dis 13:331–337PubMedCrossRef Leighton JA, Legnani P, Seidman EG (2007) Role of capsule endoscopy in inflammatory bowel disease: where we are and where we are going. Inflamm Bowel Dis 13:331–337PubMedCrossRef
2.
go back to reference Upchurch BR, Vargo JJ (2008) Small bowel enteroscopy. Rev Gastroenterol Disord 8:169–177PubMed Upchurch BR, Vargo JJ (2008) Small bowel enteroscopy. Rev Gastroenterol Disord 8:169–177PubMed
3.
go back to reference Phee L, Accoto D, Menciassi A, Stefanini C, Carrozza MC, Dario P (2002) Analysis and development of locomotion devices for the gastrointestinal tract. Biomed Eng, IEEE Trans on 49:613–616CrossRef Phee L, Accoto D, Menciassi A, Stefanini C, Carrozza MC, Dario P (2002) Analysis and development of locomotion devices for the gastrointestinal tract. Biomed Eng, IEEE Trans on 49:613–616CrossRef
4.
go back to reference Quirini M, Menciassi A, Scapellato S, Dario P, Rieber F, Ho C-N, Schostek S, Schurr MO (2008) Feasibility proof of a legged locomotion capsule for the GI tract. Gastrointest Endosc 67:1153–1158PubMedCrossRef Quirini M, Menciassi A, Scapellato S, Dario P, Rieber F, Ho C-N, Schostek S, Schurr MO (2008) Feasibility proof of a legged locomotion capsule for the GI tract. Gastrointest Endosc 67:1153–1158PubMedCrossRef
5.
go back to reference Glass P, Cheung E, Sitti M (2008) A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. Biomed Eng, IEEE Transact on 55:2759–2767CrossRef Glass P, Cheung E, Sitti M (2008) A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives. Biomed Eng, IEEE Transact on 55:2759–2767CrossRef
6.
go back to reference Wang K, Yan G, Ma G, Ye D (2009) An earthworm-like robotic endoscope system for human intestine: design, analysis, and experiment. Ann Biomed Eng 37:210–221PubMedCrossRef Wang K, Yan G, Ma G, Ye D (2009) An earthworm-like robotic endoscope system for human intestine: design, analysis, and experiment. Ann Biomed Eng 37:210–221PubMedCrossRef
7.
go back to reference Dodou D, Breedveld P, Wieringa P (2005) Friction manipulation for intestinal locomotion. Minim Invasive Ther Allied Technol 14:188–197PubMedCrossRef Dodou D, Breedveld P, Wieringa P (2005) Friction manipulation for intestinal locomotion. Minim Invasive Ther Allied Technol 14:188–197PubMedCrossRef
8.
go back to reference Dodou D, van den Berg M, van Gennip J, Breedveld P, Wieringa PA (2008) Mucoadhesive films inside the colonic tube: performance in a three-dimensional world. J R Soc Interface 5:1353–1362PubMedCrossRef Dodou D, van den Berg M, van Gennip J, Breedveld P, Wieringa PA (2008) Mucoadhesive films inside the colonic tube: performance in a three-dimensional world. J R Soc Interface 5:1353–1362PubMedCrossRef
10.
go back to reference Sliker LJ, Wang X, Schoen JA, Rentschler ME (2010) Micropatterned treads for in vivo robotic mobility. J Med Devices 4:041006–041008CrossRef Sliker LJ, Wang X, Schoen JA, Rentschler ME (2010) Micropatterned treads for in vivo robotic mobility. J Med Devices 4:041006–041008CrossRef
11.
go back to reference Miftahof RN (2005) The wave phenomena in smooth muscle syncytia. In Silico Biol (Gedrukt) 5:479–498 Miftahof RN (2005) The wave phenomena in smooth muscle syncytia. In Silico Biol (Gedrukt) 5:479–498
12.
go back to reference Mortazavi S, Smart J (1995) An investigation of some factors influencing the in vitro assessment of mucoadhesion. Int J Pharma 116:223–230CrossRef Mortazavi S, Smart J (1995) An investigation of some factors influencing the in vitro assessment of mucoadhesion. Int J Pharma 116:223–230CrossRef
13.
go back to reference Hoeg HD, Slatkin AB, Burdick JW, Grundfest WS (2000) Biomechanical modeling of the small intestine as required for the design and operation of a robotic endoscope. In: Robotics and automation, 2000. Proc ICRA’00. IEEE Int Conf, San Francisco, pp 1599–1606 Hoeg HD, Slatkin AB, Burdick JW, Grundfest WS (2000) Biomechanical modeling of the small intestine as required for the design and operation of a robotic endoscope. In: Robotics and automation, 2000. Proc ICRA’00. IEEE Int Conf, San Francisco, pp 1599–1606
14.
go back to reference Higa M, Luo Y, Okuyama T, Takagi T (2007) Characterization of the passive mechanical properties of large intestine. Int J Appl Electromagnet Mech 25:595–599 Higa M, Luo Y, Okuyama T, Takagi T (2007) Characterization of the passive mechanical properties of large intestine. Int J Appl Electromagnet Mech 25:595–599
15.
go back to reference Macagno EO, Christensen J (1980) Fluid mechanics of the duodenum. Annu Rev Fluid Mech 12:139–158CrossRef Macagno EO, Christensen J (1980) Fluid mechanics of the duodenum. Annu Rev Fluid Mech 12:139–158CrossRef
16.
go back to reference Ciarletta P, Dario P, Tendick F, Micera S (2009) Hyperelastic model of anisotropic fiber reinforcements within intestinal walls for applications in medical robotics. Int J Robot Res 28:1279–1288CrossRef Ciarletta P, Dario P, Tendick F, Micera S (2009) Hyperelastic model of anisotropic fiber reinforcements within intestinal walls for applications in medical robotics. Int J Robot Res 28:1279–1288CrossRef
17.
go back to reference Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA (2002) Mechanical properties of the human gastrointestinal tract. J Biomech 35:1417–1425PubMedCrossRef Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA (2002) Mechanical properties of the human gastrointestinal tract. J Biomech 35:1417–1425PubMedCrossRef
18.
go back to reference Jørgensen CS, Assentoft JE, Knauss D, Gregersen H, Briggs GAD (2001) Small intestine wall distribution of elastic stiffness measured with 500 MHz scanning acoustic microscopy. Ann Biomed Eng 29:1059–1063PubMedCrossRef Jørgensen CS, Assentoft JE, Knauss D, Gregersen H, Briggs GAD (2001) Small intestine wall distribution of elastic stiffness measured with 500 MHz scanning acoustic microscopy. Ann Biomed Eng 29:1059–1063PubMedCrossRef
19.
go back to reference Terry BS, Lyle AB, Schoen JA, Rentschler ME (2011) Preliminary mechanical characterization of the small bowel for in vivo robotic mobility. ASME J Biomech Eng 133(9):091010–091017 Terry BS, Lyle AB, Schoen JA, Rentschler ME (2011) Preliminary mechanical characterization of the small bowel for in vivo robotic mobility. ASME J Biomech Eng 133(9):091010–091017
20.
go back to reference Samsom M, Smout AJPM, Hebbard G, Fraser R, Omari T, Horowitz M, Dent J (1998) A novel portable perfused manometric system for recording of small intestinal motility. Neurogastroenterol Motil 10:139–148PubMedCrossRef Samsom M, Smout AJPM, Hebbard G, Fraser R, Omari T, Horowitz M, Dent J (1998) A novel portable perfused manometric system for recording of small intestinal motility. Neurogastroenterol Motil 10:139–148PubMedCrossRef
21.
go back to reference Clinton Texter E (1968) Pressure and transit in the small intestine. Dig Dis Sci 13:443–454CrossRef Clinton Texter E (1968) Pressure and transit in the small intestine. Dig Dis Sci 13:443–454CrossRef
22.
23.
go back to reference Miftahof R, Fedotov E (2005) Intestinal propulsion of a solid non-deformable bolus. J Theor Biol 235:57–70PubMedCrossRef Miftahof R, Fedotov E (2005) Intestinal propulsion of a solid non-deformable bolus. J Theor Biol 235:57–70PubMedCrossRef
24.
go back to reference Terry BS, Schoen JA, Rentschler ME (2012) Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions. IEEE Transact Biomed Eng Terry BS, Schoen JA, Rentschler ME (2012) Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions. IEEE Transact Biomed Eng
Metadata
Title
Measurements of the contact force from myenteric contractions on a solid bolus
Authors
Benjamin S. Terry
Jonathan A. Schoen
Mark E. Rentschler
Publication date
01-03-2013
Publisher
Springer-Verlag
Published in
Journal of Robotic Surgery / Issue 1/2013
Print ISSN: 1863-2483
Electronic ISSN: 1863-2491
DOI
https://doi.org/10.1007/s11701-012-0346-3

Other articles of this Issue 1/2013

Journal of Robotic Surgery 1/2013 Go to the issue