Open Access 01-02-2011 | Research

Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography

Authors: Caroline A Grant, Trang Pham, Judith Hough, Thomas Riedel, Christian Stocker, Andreas Schibler

Published in: Critical Care | Issue 1/2011

Login to get access

Abstract

Introduction

Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship.

Methods

Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared.

Results

Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort.
Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion.
When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions.

Conclusions

The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Appendix
Available only for authorised users
Literature
1.
go back to reference Fagerberg A, Stenqvist O, Aneman A: Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 2009, 53: 152-158. 10.1111/j.1399-6576.2008.01847.xPubMedCrossRef Fagerberg A, Stenqvist O, Aneman A: Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 2009, 53: 152-158. 10.1111/j.1399-6576.2008.01847.xPubMedCrossRef
2.
go back to reference Frerichs I, Pulletz S, Elke G, Reifferscheid F, Schadler D, Scholz J, Weiler N: Assessment of changes in distribution of lung perfusion by electrical impedance tomography. Respiration 2009, 77: 282-291. 10.1159/000193994PubMedCrossRef Frerichs I, Pulletz S, Elke G, Reifferscheid F, Schadler D, Scholz J, Weiler N: Assessment of changes in distribution of lung perfusion by electrical impedance tomography. Respiration 2009, 77: 282-291. 10.1159/000193994PubMedCrossRef
3.
go back to reference Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M, Hellige G: Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Transactions on Medical Imaging 2002, 21: 646-652. 10.1109/TMI.2002.800585PubMedCrossRef Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M, Hellige G: Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE Transactions on Medical Imaging 2002, 21: 646-652. 10.1109/TMI.2002.800585PubMedCrossRef
4.
go back to reference Patterson RP, Zhang J, Mason LI, Jerosch-Herold M: Variability in the cardiac EIT image as a function of electrode position, lung volume and body position. Physiological Measurement 2001, 22: 159-166. 10.1088/0967-3334/22/1/319PubMedCrossRef Patterson RP, Zhang J, Mason LI, Jerosch-Herold M: Variability in the cardiac EIT image as a function of electrode position, lung volume and body position. Physiological Measurement 2001, 22: 159-166. 10.1088/0967-3334/22/1/319PubMedCrossRef
5.
go back to reference Vonk Noordegraaf A, Kunst PW, Janse A, Marcus JT, Postmus PE, Faes TJ, de Vries PM: Pulmonary perfusion measured by means of electrical impedance tomography. Physiological Measurement 1998, 19: 263-273. 10.1088/0967-3334/19/2/013PubMedCrossRef Vonk Noordegraaf A, Kunst PW, Janse A, Marcus JT, Postmus PE, Faes TJ, de Vries PM: Pulmonary perfusion measured by means of electrical impedance tomography. Physiological Measurement 1998, 19: 263-273. 10.1088/0967-3334/19/2/013PubMedCrossRef
6.
go back to reference Vonk-Noordegraaf A, Janse A, Marcus JT, Bronzwaer JG, Postmust PE, Faes TJ, De Vries PM: Determination of stroke volume by means of electrical impedance tomography. Physiological Measurement 2000, 21: 285-293. 10.1088/0967-3334/21/2/308PubMedCrossRef Vonk-Noordegraaf A, Janse A, Marcus JT, Bronzwaer JG, Postmust PE, Faes TJ, De Vries PM: Determination of stroke volume by means of electrical impedance tomography. Physiological Measurement 2000, 21: 285-293. 10.1088/0967-3334/21/2/308PubMedCrossRef
7.
go back to reference Fagerberg A, Stenqvist O, Aneman A: Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model. Critical Care 2009, 13: R34. 10.1186/cc7741PubMedPubMedCentralCrossRef Fagerberg A, Stenqvist O, Aneman A: Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model. Critical Care 2009, 13: R34. 10.1186/cc7741PubMedPubMedCentralCrossRef
8.
go back to reference Bodenstein M, David M, Markstaller K: Principles of electrical impedance tomography and its clinical application. Crit Care Med 2009, 37: 713-724. 10.1097/CCM.0b013e3181958d2fPubMedCrossRef Bodenstein M, David M, Markstaller K: Principles of electrical impedance tomography and its clinical application. Crit Care Med 2009, 37: 713-724. 10.1097/CCM.0b013e3181958d2fPubMedCrossRef
9.
go back to reference Frerichs I, Dargaville PA, Dudykevych T, Rimensberger PC: Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? Intensive Care Medicine 2003, 29: 2312-2316. 10.1007/s00134-003-2029-zPubMedCrossRef Frerichs I, Dargaville PA, Dudykevych T, Rimensberger PC: Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? Intensive Care Medicine 2003, 29: 2312-2316. 10.1007/s00134-003-2029-zPubMedCrossRef
10.
go back to reference Hahn G, Dudykevych T, Frerichs I, Hellige G: EIT System for clinical and space applications. Proceedings of the 2nd European Medical and Biological Engineering Conference: December 4-8, 2002, Vienna, Austria, IFMBE Proceedings Series 3 110-111. Hahn G, Dudykevych T, Frerichs I, Hellige G: EIT System for clinical and space applications. Proceedings of the 2nd European Medical and Biological Engineering Conference: December 4-8, 2002, Vienna, Austria, IFMBE Proceedings Series 3 110-111.
11.
go back to reference Carlisle HR, Armstrong RK, Davis PG, Schibler A, Frerichs I, Tingay DG: Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation. Intensive Care Medicine 2010, 36: 2101-2108. 10.1007/s00134-010-2049-4PubMedCrossRef Carlisle HR, Armstrong RK, Davis PG, Schibler A, Frerichs I, Tingay DG: Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation. Intensive Care Medicine 2010, 36: 2101-2108. 10.1007/s00134-010-2049-4PubMedCrossRef
12.
go back to reference Dunlop S, Hough J, Riedel T, Fraser JF, Dunster K, Schibler A: Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain. Physiological Measurement 2006, 27: 1151-1165. 10.1088/0967-3334/27/11/008PubMedCrossRef Dunlop S, Hough J, Riedel T, Fraser JF, Dunster K, Schibler A: Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain. Physiological Measurement 2006, 27: 1151-1165. 10.1088/0967-3334/27/11/008PubMedCrossRef
13.
go back to reference Pulletz S, van Genderingen HR, Schmitz G, Zick G, Schadler D, Scholz J, Weiler N, Frerichs I: Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT. Physiological Measurement 2006, 27: S115-127. 10.1088/0967-3334/27/5/S10PubMedCrossRef Pulletz S, van Genderingen HR, Schmitz G, Zick G, Schadler D, Scholz J, Weiler N, Frerichs I: Comparison of different methods to define regions of interest for evaluation of regional lung ventilation by EIT. Physiological Measurement 2006, 27: S115-127. 10.1088/0967-3334/27/5/S10PubMedCrossRef
14.
go back to reference Riedel T, Fraser JF, Dunster K, Fitzgibbon J, Schibler A: Effect of smoke inhalation on viscoelastic properties and ventilation distribution in sheep. Journal of Applied Physiology 2006, 101: 763-770. 10.1152/japplphysiol.01635.2005PubMedCrossRef Riedel T, Fraser JF, Dunster K, Fitzgibbon J, Schibler A: Effect of smoke inhalation on viscoelastic properties and ventilation distribution in sheep. Journal of Applied Physiology 2006, 101: 763-770. 10.1152/japplphysiol.01635.2005PubMedCrossRef
15.
go back to reference Riedel T, Richards T, Schibler A: The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects. Intensive Care Medicine 2005, 31: 1522-1528. 10.1007/s00134-005-2734-xPubMedCrossRef Riedel T, Richards T, Schibler A: The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjects. Intensive Care Medicine 2005, 31: 1522-1528. 10.1007/s00134-005-2734-xPubMedCrossRef
16.
go back to reference Glenny RW, Bernard S, Robertson HT, Hlastala MP: Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates. J Appl Physiol 1999, 86: 623-632.PubMed Glenny RW, Bernard S, Robertson HT, Hlastala MP: Gravity is an important but secondary determinant of regional pulmonary blood flow in upright primates. J Appl Physiol 1999, 86: 623-632.PubMed
17.
go back to reference Jones AT, Hansell DM, Evans TW: Pulmonary perfusion in supine and prone positions: an electron-beam computed tomography study. J Appl Physiol 2001, 90: 1342-1348. 10.1063/1.1376404PubMedCrossRef Jones AT, Hansell DM, Evans TW: Pulmonary perfusion in supine and prone positions: an electron-beam computed tomography study. J Appl Physiol 2001, 90: 1342-1348. 10.1063/1.1376404PubMedCrossRef
18.
go back to reference Amis TC, Jones HA, Hughes JM: Effect of posture on inter-regional distribution of pulmonary perfusion and VA/Q ratios in man. Respiration Physiology 1984, 56: 169-182. 10.1016/0034-5687(84)90101-4PubMedCrossRef Amis TC, Jones HA, Hughes JM: Effect of posture on inter-regional distribution of pulmonary perfusion and VA/Q ratios in man. Respiration Physiology 1984, 56: 169-182. 10.1016/0034-5687(84)90101-4PubMedCrossRef
19.
go back to reference Deibele JM, Luepschen H, Leonhardt S: Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Physiological Measurement 2008, 29: S1-14. 10.1088/0967-3334/29/6/S01PubMedCrossRef Deibele JM, Luepschen H, Leonhardt S: Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Physiological Measurement 2008, 29: S1-14. 10.1088/0967-3334/29/6/S01PubMedCrossRef
Metadata
Title
Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography
Authors
Caroline A Grant
Trang Pham
Judith Hough
Thomas Riedel
Christian Stocker
Andreas Schibler
Publication date
01-02-2011
Publisher
BioMed Central
Published in
Critical Care / Issue 1/2011
Electronic ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc9985

Other articles of this Issue 1/2011

Critical Care 1/2011 Go to the issue