Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2009

01-05-2009 | Knee

Measurement of joint gap load in patella everted and reset position during total knee arthroplasty

Authors: Nobuyuki Yoshino, Nobuyoshi Watanabe, Yoshinobu Watanabe, Yukihisa Fukuda, Shinro Takai

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 5/2009

Login to get access

Abstract

An original tensor system was developed to directly measure the load between femoral trial component and tibial cut surface in vivo in both patella everted and reset positions during total knee arthroplasty (TKA). We used this system during posterior-stabilized (PS) and cruciate-retaining (CR) TKA. In PS-TKA, there was no significant difference between the loads in extension in patella everted position and reset position. In flexion, however, there was significant increase of load in patella reset position compared to in everted position. In CR-TKA, there was no significant difference between the loads in patella everted position and in patella reset position in either extension or flexion. It was found that the effect of patella position on joint gap load was different between PS-TKA and CR-TKA. It is important to be aware that, when performing PS-KA, the load in flexion gap will increase, in other words, flexion gap distance will decrease by resetting the patella.
Literature
1.
go back to reference Asano H, Hoshino A, Wilton T (2004) Soft-tissue tension total knee arthroplasty. J Arthroplasty 19:558–561PubMedCrossRef Asano H, Hoshino A, Wilton T (2004) Soft-tissue tension total knee arthroplasty. J Arthroplasty 19:558–561PubMedCrossRef
2.
go back to reference Attfield SF, Warren-Forward M, Wilton T, Sambatakakis A (1994) Measurement of soft tissue imbalance in total knee arthroplasty using electronic instrumentation. Med Eng Phys 16:501–505PubMedCrossRef Attfield SF, Warren-Forward M, Wilton T, Sambatakakis A (1994) Measurement of soft tissue imbalance in total knee arthroplasty using electronic instrumentation. Med Eng Phys 16:501–505PubMedCrossRef
3.
go back to reference Booth RE (2003) Tensioners: essential for accurate performance of TKA. Orthopedics 26:962–964PubMed Booth RE (2003) Tensioners: essential for accurate performance of TKA. Orthopedics 26:962–964PubMed
4.
go back to reference D’Lima DD, Patil S, Steklov N, Slamin JE, Colwell CW Jr (2006) Tibial force measured in vivo after total knee arthroplasty. J Arthroplasty 21:255–262PubMedCrossRef D’Lima DD, Patil S, Steklov N, Slamin JE, Colwell CW Jr (2006) Tibial force measured in vivo after total knee arthroplasty. J Arthroplasty 21:255–262PubMedCrossRef
5.
go back to reference Freeman MAR, Todd RC, Bamert P, Day WH (1978) ICLH arthroplasty of the knee: 1968–1977. J Bone Joint Surg 60-B:339–344 Freeman MAR, Todd RC, Bamert P, Day WH (1978) ICLH arthroplasty of the knee: 1968–1977. J Bone Joint Surg 60-B:339–344
6.
go back to reference Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef Griffin FM, Insall JN, Scuderi GR (2000) Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 15:970–973PubMedCrossRef
7.
go back to reference Insall JN (1984) Total knee replacement. In: Insall JN (ed) Surgery of the knee. Churchill-Livingstone, New York Insall JN (1984) Total knee replacement. In: Insall JN (ed) Surgery of the knee. Churchill-Livingstone, New York
8.
go back to reference Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef Matsumoto T, Muratsu H, Tsumura N, Mizuno K, Kuroda R, Yoshiya S, Kurosaka M (2006) Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system. J Biomech Eng 128:867–871PubMedCrossRef
9.
go back to reference Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Kubo S, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef Matsumoto T, Mizuno K, Muratsu H, Tsumura N, Fukase N, Kubo S, Yoshiya S, Kurosaka M, Kuroda R (2007) Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15:1013–1018PubMedCrossRef
10.
go back to reference Morris BA, D’Lima DD, Slamin J, Kovacevic N, Arms SW, Townsend CP, Colwell Jr CW (2001) e-Knee: evolution of the electronic knee prosthesis. J Bone Joint Surg 83-A(supplement 2, Part 1):62–66 Morris BA, D’Lima DD, Slamin J, Kovacevic N, Arms SW, Townsend CP, Colwell Jr CW (2001) e-Knee: evolution of the electronic knee prosthesis. J Bone Joint Surg 83-A(supplement 2, Part 1):62–66
11.
go back to reference Sambatakakis A, Attfield SF, Newton G (1993) Quantification of soft-tissue imbalance in condylar knee arthroplasty. J Biomed Eng 15:339–343PubMedCrossRef Sambatakakis A, Attfield SF, Newton G (1993) Quantification of soft-tissue imbalance in condylar knee arthroplasty. J Biomed Eng 15:339–343PubMedCrossRef
12.
go back to reference Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Why are total knee arthroplasties failing today. Clin Orthop 404:7–13PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Why are total knee arthroplasties failing today. Clin Orthop 404:7–13PubMedCrossRef
13.
go back to reference Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: a new roentgenographic technique to assess the rotational deformity and alignment of the distal femur. J Arthroplasty 18:478–483PubMedCrossRef Takai S, Yoshino N, Isshiki T, Hirasawa Y (2003) Kneeling view: a new roentgenographic technique to assess the rotational deformity and alignment of the distal femur. J Arthroplasty 18:478–483PubMedCrossRef
14.
go back to reference Viskontas DG, Skrinskas TV, Johnson JA, King GJ, Winemaker MJ, Chess DG (2007) Computer-assisted gap equalization in total knee arthroplasty. J Arthroplasty 22:334–342PubMedCrossRef Viskontas DG, Skrinskas TV, Johnson JA, King GJ, Winemaker MJ, Chess DG (2007) Computer-assisted gap equalization in total knee arthroplasty. J Arthroplasty 22:334–342PubMedCrossRef
15.
go back to reference Wasielewski RC, Galat DD, Komistek RD (2005) Correlation of compartment pressure data from an intraoperative sensing device with postoperative fluoroscopic kinematic results in TKA patients. J Biomech 38:333–339PubMedCrossRef Wasielewski RC, Galat DD, Komistek RD (2005) Correlation of compartment pressure data from an intraoperative sensing device with postoperative fluoroscopic kinematic results in TKA patients. J Biomech 38:333–339PubMedCrossRef
16.
go back to reference Winemakaer MJ (2002) Perfect balance in total knee arthroplasty. J Arthroplasty 17:2–10CrossRef Winemakaer MJ (2002) Perfect balance in total knee arthroplasty. J Arthroplasty 17:2–10CrossRef
17.
go back to reference Yagishita K, Muneta T, Ikeda H (2003) Step-by-step measurement of soft tissue balancing during total knee arthroplasty for patients with varus knees. J Arthroplasty 18:313–320PubMedCrossRef Yagishita K, Muneta T, Ikeda H (2003) Step-by-step measurement of soft tissue balancing during total knee arthroplasty for patients with varus knees. J Arthroplasty 18:313–320PubMedCrossRef
18.
go back to reference Zalzal P, Papini M, Petruccelli D, de Beer J, Winemaker MJ (2004) An in vivo biomechanical analysis of the soft-tissue envelope of osteoarthritis knees. J Arthroplasty 19:217–223PubMedCrossRef Zalzal P, Papini M, Petruccelli D, de Beer J, Winemaker MJ (2004) An in vivo biomechanical analysis of the soft-tissue envelope of osteoarthritis knees. J Arthroplasty 19:217–223PubMedCrossRef
Metadata
Title
Measurement of joint gap load in patella everted and reset position during total knee arthroplasty
Authors
Nobuyuki Yoshino
Nobuyoshi Watanabe
Yoshinobu Watanabe
Yukihisa Fukuda
Shinro Takai
Publication date
01-05-2009
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 5/2009
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-008-0656-1

Other articles of this Issue 5/2009

Knee Surgery, Sports Traumatology, Arthroscopy 5/2009 Go to the issue