Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription

Authors: M. Fischbach, J. Terzic, V. Laugel, B. Escande, Cl. Dangelser, A. Helmstetter

Published in: Pediatric Nephrology | Issue 10/2003

Login to get access

Abstract

The prescription of peritoneal dialysis should be individualized based on parameters of tolerance and adequacy. Determination of the intraperitoneal fill volume is essential for optimal patient care. Fill volume enhancement is a factor of exchange surface area recruitment: the wetted, contact peritoneal dialysis membrane. Nevertheless, fill volume enhancement can also lead to patient discomfort, with the potential risk of too high an intraperitoneal pressure (hernia, gastro-esophageal reflux). The perception of the individual patient is also a subjective parameter of fill volume tolerance assessment. In contrast, measurement of the hydrostatic intraperitoneal pressure (IPP, cmH2O) allows an objective approach to fill volume tolerance. From our clinical experience of more than 10 years of IPP measurements in child care, we can give a recommendation for normal values in children: less than 18 cm of water, usually between 5 and 15 cm, correlated to the intraperitoneal fill volume (naturally), but individually taking into account age, gender, "accustomization" and overall body mass index.
Literature
1.
go back to reference Fischbach M, Terzic J, Menouer S, Haraldsson B (2000) Optimal volume prescription for children on peritoneal dialysis. Perit Dial Int 20:603–606PubMed Fischbach M, Terzic J, Menouer S, Haraldsson B (2000) Optimal volume prescription for children on peritoneal dialysis. Perit Dial Int 20:603–606PubMed
2.
go back to reference Durand PY (2000) Optimization of fill volumes in automated peritoneal dialysis. Perit Dial Int 20:601–602PubMed Durand PY (2000) Optimization of fill volumes in automated peritoneal dialysis. Perit Dial Int 20:601–602PubMed
3.
go back to reference Fischbach M, Stefanidis CJ, Watson A for the European Pediatric Dialysis Working Group (2002) Guidelines by an ad hoc European committee on adequacy of the pediatric peritoneal dialysis prescription. Nephrol Dial Transplant 17:380–385CrossRefPubMed Fischbach M, Stefanidis CJ, Watson A for the European Pediatric Dialysis Working Group (2002) Guidelines by an ad hoc European committee on adequacy of the pediatric peritoneal dialysis prescription. Nephrol Dial Transplant 17:380–385CrossRefPubMed
4.
go back to reference Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1996) Measurement of hydrostatic intraperitoneal pressure: a necessary routine test. Perit Dial Int 16:S84–S87PubMed Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1996) Measurement of hydrostatic intraperitoneal pressure: a necessary routine test. Perit Dial Int 16:S84–S87PubMed
5.
go back to reference Fischbach M, Terzic J, Becmeur F, Lahlou A, Desprez P, Battouche D, Geisert J (1996) Relationship between intraperitoneal hydrostatic pressure and dialysate volume in children on PD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 16:330–340 Fischbach M, Terzic J, Becmeur F, Lahlou A, Desprez P, Battouche D, Geisert J (1996) Relationship between intraperitoneal hydrostatic pressure and dialysate volume in children on PD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 16:330–340
6.
go back to reference Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1992) Routine measurement of hydrostatic intraperitoneal pressure. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 8:108–112 Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1992) Routine measurement of hydrostatic intraperitoneal pressure. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 8:108–112
7.
go back to reference Fischbach M, Terzic J, Dangelser C, Schneider P, Roger ML, Geisert J (1997) Improved dialysis dose by optimizing intraperitoneal volume prescription thanks to intraperitoneal pressure measurements in children. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 13:271–273 Fischbach M, Terzic J, Dangelser C, Schneider P, Roger ML, Geisert J (1997) Improved dialysis dose by optimizing intraperitoneal volume prescription thanks to intraperitoneal pressure measurements in children. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 13:271–273
8.
go back to reference Ventura MJ, Amato D, Correa-Rotter R, Paniagna R (2000) Relationship between fill volume, intraperitoneal pressure, body size and subjective discomfort perception in CAPD patients. Perit Dial Int 20:188–193PubMed Ventura MJ, Amato D, Correa-Rotter R, Paniagna R (2000) Relationship between fill volume, intraperitoneal pressure, body size and subjective discomfort perception in CAPD patients. Perit Dial Int 20:188–193PubMed
9.
go back to reference Scanziani R, Dozio B, Pasi A, Sangalli L, Bonforte G, Rivera R, Surian M (2001) Optimization of dialysate flow on automated peritoneal dialysis (APD). Perit Dial Int 21 (Suppl 1) S31 (abstract) Scanziani R, Dozio B, Pasi A, Sangalli L, Bonforte G, Rivera R, Surian M (2001) Optimization of dialysate flow on automated peritoneal dialysis (APD). Perit Dial Int 21 (Suppl 1) S31 (abstract)
10.
go back to reference Fischbach M, Terzic J, Menouer S, Provot E, Laugel V (2001) Relationship between fill volume (IPV), intraperitoneal pressure (IPP) and body mass index in children on chronic peritoneal dialysis (PD). Perit Dial Int 21 (Suppl 1) S88 (abstract); Perit Dial Int 2003 (in press) Fischbach M, Terzic J, Menouer S, Provot E, Laugel V (2001) Relationship between fill volume (IPV), intraperitoneal pressure (IPP) and body mass index in children on chronic peritoneal dialysis (PD). Perit Dial Int 21 (Suppl 1) S88 (abstract); Perit Dial Int 2003 (in press)
11.
go back to reference Barak N, Ehrenpreis ED, Harrison JR, Sitrin MD (2002) Gastro-oesophageal reflux disease in obesity: pathophysiological and therapeutic considerations. Obes Rev 3:9–15CrossRefPubMed Barak N, Ehrenpreis ED, Harrison JR, Sitrin MD (2002) Gastro-oesophageal reflux disease in obesity: pathophysiological and therapeutic considerations. Obes Rev 3:9–15CrossRefPubMed
12.
go back to reference Fischbach M, Terzic J, Schneider P, Roger ML (1998) Effect of posture on intraperitoneal pressure and peritoneal equilibration test in children. Pediatr Nephrol 12:311–314CrossRefPubMed Fischbach M, Terzic J, Schneider P, Roger ML (1998) Effect of posture on intraperitoneal pressure and peritoneal equilibration test in children. Pediatr Nephrol 12:311–314CrossRefPubMed
13.
go back to reference Fischbach M, Desprez P, Donnars F, Geisert J (1994) Hydrostatic intraperitoneal pressure in children on peritoneal dialysis: practical implications. An 18-month clinical experience. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 10:294–296 Fischbach M, Desprez P, Donnars F, Geisert J (1994) Hydrostatic intraperitoneal pressure in children on peritoneal dialysis: practical implications. An 18-month clinical experience. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 10:294–296
14.
go back to reference Fischbach M, Terzic J, Chauve S, Laugel V, Muller A, Haraldsson B (2003) In children, the peritoneal area available for exchange is influenced by the composition of the peritoneal dialysis fluid. J Am Soc Nephrol (in press) Fischbach M, Terzic J, Chauve S, Laugel V, Muller A, Haraldsson B (2003) In children, the peritoneal area available for exchange is influenced by the composition of the peritoneal dialysis fluid. J Am Soc Nephrol (in press)
15.
go back to reference Fischbach M, Lahlou A, Becmeur F, Desprez P, Geisert J (1995) Hydrostatic intraperitoneal pressure in infants on peritoneal dialysis: interest after surgical peritoneal catheter implantation. Pediatr Nephrol 9:C44 (abstract) Fischbach M, Lahlou A, Becmeur F, Desprez P, Geisert J (1995) Hydrostatic intraperitoneal pressure in infants on peritoneal dialysis: interest after surgical peritoneal catheter implantation. Pediatr Nephrol 9:C44 (abstract)
16.
go back to reference Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1993) Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 9:46–48 Durand PY, Chanliau J, Gamberoni J, Hestin D, Kessler M (1993) Intraperitoneal hydrostatic pressure and ultrafiltration volume in CAPD. In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 9:46–48
17.
go back to reference Aranda RA, Romao Junior JE, Kakehashi E, Domingos W, Sabbaga E, Marcondes M, Abensur H (2000) Intraperitoneal pressure and hernias in children on peritoneal dialysis. Pediatr Nephrol 14:22–24PubMed Aranda RA, Romao Junior JE, Kakehashi E, Domingos W, Sabbaga E, Marcondes M, Abensur H (2000) Intraperitoneal pressure and hernias in children on peritoneal dialysis. Pediatr Nephrol 14:22–24PubMed
18.
go back to reference Fischbach M, Terzic J, Gaugler C, Bergere C, Munch K, Hamel G, Provot E, Donnars F (1998) Impact of an increased intraperitoneal fill volume both on tolerance and on dialysis effectiveness in children In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 14:258–264 Fischbach M, Terzic J, Gaugler C, Bergere C, Munch K, Hamel G, Provot E, Donnars F (1998) Impact of an increased intraperitoneal fill volume both on tolerance and on dialysis effectiveness in children In: Khanna R, Nolph KD, Prowant BF, Twardowski ZJ, Oreopoulos DG (eds) Advances in peritoneal dialysis. Peritoneal Dialysis Publications Toronto 14:258–264
19.
go back to reference Keshaviah P, Emerson PF, Vonesh EF, Brandes JC (1994) Relationship between body size, fill volume and mass transfer coefficient in peritoneal dialysis. J Am Soc Nephrol 4:1870–1876 Keshaviah P, Emerson PF, Vonesh EF, Brandes JC (1994) Relationship between body size, fill volume and mass transfer coefficient in peritoneal dialysis. J Am Soc Nephrol 4:1870–1876
20.
go back to reference Brandes JC, Packard WJ, Walters SK, Fritsche C (1995) Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 25:603–610PubMed Brandes JC, Packard WJ, Walters SK, Fritsche C (1995) Optimization of dialysate flow and mass transfer during automated peritoneal dialysis. Am J Kidney Dis 25:603–610PubMed
21.
go back to reference Fischbach M, Haraldsson B (2001) Dynamic changes of total pore area available for peritoneal exchange in children. J Am Soc Nephrol 12:1524–1529PubMed Fischbach M, Haraldsson B (2001) Dynamic changes of total pore area available for peritoneal exchange in children. J Am Soc Nephrol 12:1524–1529PubMed
22.
go back to reference Chagnac A, Herskovitz P, Yaacov O, Weinstein T, Hirsh J, Katz M, Gafter U (2002) Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients. J Am Soc Nephrol 13:2254–2259 Chagnac A, Herskovitz P, Yaacov O, Weinstein T, Hirsh J, Katz M, Gafter U (2002) Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients. J Am Soc Nephrol 13:2254–2259
23.
go back to reference Harris KP, Keogh AM, Alderson L (2001) Peritoneal dialysis fill volume: can the patient tell the difference? Perit Dial Int 21 (Suppl 3) S144–S147 Harris KP, Keogh AM, Alderson L (2001) Peritoneal dialysis fill volume: can the patient tell the difference? Perit Dial Int 21 (Suppl 3) S144–S147
Metadata
Title
Measurement of hydrostatic intraperitoneal pressure: a useful tool for the improvement of dialysis dose prescription
Authors
M. Fischbach
J. Terzic
V. Laugel
B. Escande
Cl. Dangelser
A. Helmstetter
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
Pediatric Nephrology / Issue 10/2003
Print ISSN: 0931-041X
Electronic ISSN: 1432-198X
DOI
https://doi.org/10.1007/s00467-003-1199-9

Other articles of this Issue 10/2003

Pediatric Nephrology 10/2003 Go to the issue