Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 2/2014

01-02-2014 | Basic Science

Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation

Authors: Alberto Domínguez-Vicent, Daniel Monsálvez-Romín, Cari Pérez-Vives, Teresa Ferrer-Blasco, Robert Montés-Micó

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 2/2014

Login to get access

Abstract

Purpose

To measure angle kappa distance with Orbscan II and Galilei G4, and to evaluate possible variations in this value for different accommodation degrees.

Methods

Angle kappa was measured using the Orbscan II and the Galilei G4 in the right eye of 80 patients aged from 20 to 40 years. This value was measured three times per eye and per device, and the average was retained. Angle kappa was measured for far vision using the Orbscan II and the Galilei G4 in a random order for each subject. The Galilei G4 was used to measure angle kappa as a function of accommodation, where the first measure started at +1 D and the vergence was changed until reaching −4 D, in 1 D steps. In both measures, the kappa distance was expressed in millimetres.

Results

At distance, the values of angle kappa were 0.43 ± 0.13 mm and 0.27 ± 0.15 mm measured with the Orbscan II and Galilei G4 systems respectively. Statistical significant differences were found (P < 0.01). With regard to the angle kappa values obtained as a function of accommodation, the values were 0.25 ± 0.15 mm, 0.26 ± 0.15 mm, 0.30 ± 0.20 mm, 0.27 ± 0.15 and 0.26 ± 0.15 mm, for +1 D, −1 D, −2 D, -3 D and −4 D respectively. No statistical significant differences were found among 0 D and the other vergences evaluated (P > 0.01).

Conclusions

For far vision, Orbscan II measured significantly higher angle kappa values than Galilei G4, the mean difference being 0.16 ± 0.08 mm. For different accommodation levels, the kappa distance did not change significantly.
Literature
1.
go back to reference Benjamin WJ (2006) Ocular motility. In: Pensyl CD, Benjamin WJ (eds) Borish’s clinical refraction, 2nd edn. Elsevier, Butterworth Heinemann. Inc, St. Louis, pp 385–386 Benjamin WJ (2006) Ocular motility. In: Pensyl CD, Benjamin WJ (eds) Borish’s clinical refraction, 2nd edn. Elsevier, Butterworth Heinemann. Inc, St. Louis, pp 385–386
2.
go back to reference Basmak H, Sahin A, Yildirim N, Papakostas TD, Kanellopoulos AJ (2007) Measurement of angle kappa with synoptophore and orbscan II in a normal population. J Refract Surg 23:456–460PubMed Basmak H, Sahin A, Yildirim N, Papakostas TD, Kanellopoulos AJ (2007) Measurement of angle kappa with synoptophore and orbscan II in a normal population. J Refract Surg 23:456–460PubMed
3.
go back to reference Hashemi H, Khabazkhoob M, Yazdani K, Mehravaran S, Jafarzadehpur R, Fotouhi A (2010) Distribution of angle kappa measurements with orbscan II in a population-based survey. J Refract Surg 26(12):966–971PubMedCrossRef Hashemi H, Khabazkhoob M, Yazdani K, Mehravaran S, Jafarzadehpur R, Fotouhi A (2010) Distribution of angle kappa measurements with orbscan II in a population-based survey. J Refract Surg 26(12):966–971PubMedCrossRef
4.
go back to reference Qazi MA, Roberts CJ, Mahmoud AM, Pepose JS (2005) Topographic and bioechanical differences between hyperopic and myopic laser in situ keratomileusis. J Cataract Refract Surg 31:48–60PubMedCrossRef Qazi MA, Roberts CJ, Mahmoud AM, Pepose JS (2005) Topographic and bioechanical differences between hyperopic and myopic laser in situ keratomileusis. J Cataract Refract Surg 31:48–60PubMedCrossRef
5.
go back to reference Tabernero J, Benito A, Alcón E, Artal P (2007) Mechanism of compensation of aberrations in the human eye. J Opt Soc Am 24(10):3274–3282CrossRef Tabernero J, Benito A, Alcón E, Artal P (2007) Mechanism of compensation of aberrations in the human eye. J Opt Soc Am 24(10):3274–3282CrossRef
6.
go back to reference Von Norden G, Campos E (2002) Examination of the patient II. In: Binocular vision and ocular motility—theory and management of strabismus. 6th ed. Mosby, St Louis, pp 168–173 Von Norden G, Campos E (2002) Examination of the patient II. In: Binocular vision and ocular motility—theory and management of strabismus. 6th ed. Mosby, St Louis, pp 168–173
7.
go back to reference Basmak H, Sahin A, Yildirim N, Saricicek T, Yurdakul S (2007) Measurement of angle kappa in strabismic individuals. Strabismus 15:193–196PubMedCrossRef Basmak H, Sahin A, Yildirim N, Saricicek T, Yurdakul S (2007) Measurement of angle kappa in strabismic individuals. Strabismus 15:193–196PubMedCrossRef
8.
go back to reference Prakash G, Prakash DR, Agarwal A, Kumar DA, Agarwal A, Jacob S (2011) Predictive factor and kappa value analysis for visual satisfaction in patients with multifocal IOL implantation. Eye 25:1187–1193PubMedCrossRef Prakash G, Prakash DR, Agarwal A, Kumar DA, Agarwal A, Jacob S (2011) Predictive factor and kappa value analysis for visual satisfaction in patients with multifocal IOL implantation. Eye 25:1187–1193PubMedCrossRef
9.
go back to reference Espinosa J, Mas D, Kasprzak HT (2009) Corneal primary aberrations compensation by oblique light incidence. J Biomed Opt 14:044003PubMedCrossRef Espinosa J, Mas D, Kasprzak HT (2009) Corneal primary aberrations compensation by oblique light incidence. J Biomed Opt 14:044003PubMedCrossRef
10.
go back to reference Berrio E, Tabernero J, Artal P (2010) Optical aberrations and alignment of the eye with age. J Vis 10(14):14,1–17CrossRef Berrio E, Tabernero J, Artal P (2010) Optical aberrations and alignment of the eye with age. J Vis 10(14):14,1–17CrossRef
11.
go back to reference Merrill KS, Summers CG (2012) Positive angle kappa: a possible sign of aniridia. Am Orthop J 62:70–76CrossRef Merrill KS, Summers CG (2012) Positive angle kappa: a possible sign of aniridia. Am Orthop J 62:70–76CrossRef
12.
go back to reference Merrill KS, Lavoie JD, King RA, Summers CG (2004) Positive angle kappa in albinism. J AAPOS 8:237–239PubMedCrossRef Merrill KS, Lavoie JD, King RA, Summers CG (2004) Positive angle kappa in albinism. J AAPOS 8:237–239PubMedCrossRef
13.
go back to reference Wu L, Zhou X, Chu R, Wang Q (2009) Photoablation centration on the corneal optical center in myopic LASIK using AOV excimer laser. Eur J Ophthalmol 19:923–929PubMed Wu L, Zhou X, Chu R, Wang Q (2009) Photoablation centration on the corneal optical center in myopic LASIK using AOV excimer laser. Eur J Ophthalmol 19:923–929PubMed
14.
go back to reference Pande M, Hillman JS (1993) Optical zone centration in keratorefractive surgery. Entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometric corneal center? Ophthalmology 100:1230–1237PubMedCrossRef Pande M, Hillman JS (1993) Optical zone centration in keratorefractive surgery. Entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometric corneal center? Ophthalmology 100:1230–1237PubMedCrossRef
15.
go back to reference Wachler BS, Kom TS, Chandra NS, Michel FK (2003) Decentration of the optical zone: centering on the pupil versus the coaxially sighted corneal light reflex in LASIK for hyperopia. J Refract Surg 19:464–465PubMed Wachler BS, Kom TS, Chandra NS, Michel FK (2003) Decentration of the optical zone: centering on the pupil versus the coaxially sighted corneal light reflex in LASIK for hyperopia. J Refract Surg 19:464–465PubMed
16.
go back to reference Nepomuceno RL, Wachler BS, Kim J, Scruggs R, Sato M (2004) Laser in situ keratomileusis for hyperopia with the LADARVision 4000 with centration on the coaxially sighted corneal light reflex. J Cataract Refract Surg 30:1281–1286PubMedCrossRef Nepomuceno RL, Wachler BS, Kim J, Scruggs R, Sato M (2004) Laser in situ keratomileusis for hyperopia with the LADARVision 4000 with centration on the coaxially sighted corneal light reflex. J Cataract Refract Surg 30:1281–1286PubMedCrossRef
17.
go back to reference Chan CC, Wachler BS (2006) Centration analysis of ablation over the coaxial corneal light reflex for hyperopic LASIK. J Refract Surg 22:467–471PubMed Chan CC, Wachler BS (2006) Centration analysis of ablation over the coaxial corneal light reflex for hyperopic LASIK. J Refract Surg 22:467–471PubMed
18.
go back to reference Prakash G, Agarwal A, Prakash DR, Kumar DA, Agarwal A, Jacob S (2011) Role of angle kappa in patient dissatisfaction with refractive-design multifocal intraocular lenses. J Cataract Refract surg 37:1739–1740PubMedCrossRef Prakash G, Agarwal A, Prakash DR, Kumar DA, Agarwal A, Jacob S (2011) Role of angle kappa in patient dissatisfaction with refractive-design multifocal intraocular lenses. J Cataract Refract surg 37:1739–1740PubMedCrossRef
19.
go back to reference Nishi Y, Hirnschall N, Crnej A, Gangwani V, Tabernero J, Artal P, Findl O (2010) Reproducibility of intraocular lens decentration and tilt measurement using a clinical Punkinje meter. J Cataract Refract Surg 36:1529–1535PubMedCrossRef Nishi Y, Hirnschall N, Crnej A, Gangwani V, Tabernero J, Artal P, Findl O (2010) Reproducibility of intraocular lens decentration and tilt measurement using a clinical Punkinje meter. J Cataract Refract Surg 36:1529–1535PubMedCrossRef
20.
go back to reference Tabernero J, Piers P, Benito A, Redondo M, Artal P (2006) Predicting the optical performance of eyes implanted with IOLs to correct spherical aberrations. Invest Ophthalmol Vis Sci 47:4651–4658PubMedCrossRef Tabernero J, Piers P, Benito A, Redondo M, Artal P (2006) Predicting the optical performance of eyes implanted with IOLs to correct spherical aberrations. Invest Ophthalmol Vis Sci 47:4651–4658PubMedCrossRef
21.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMedCrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMedCrossRef
22.
go back to reference Willson MA, Campbell MC, Simonet P (1992) The Julius F. Neumueller awrard in optics, 1989: change of pupil centration with change of illumination and pupil size. Optom Vis Sci 69:129–136CrossRef Willson MA, Campbell MC, Simonet P (1992) The Julius F. Neumueller awrard in optics, 1989: change of pupil centration with change of illumination and pupil size. Optom Vis Sci 69:129–136CrossRef
23.
go back to reference Uozato H, Guyton DL (1987) Centering corneal surgical procedures. Am J Ophthalmology 103:264–275 Uozato H, Guyton DL (1987) Centering corneal surgical procedures. Am J Ophthalmology 103:264–275
24.
go back to reference Espinosa J, Mas D, Kasprzak HT (2009) Corneal primary aberrations compensation by oblique light incidence. J Biomed Opt 14:044003PubMedCrossRef Espinosa J, Mas D, Kasprzak HT (2009) Corneal primary aberrations compensation by oblique light incidence. J Biomed Opt 14:044003PubMedCrossRef
25.
go back to reference Madrid-Costa D, Ruiz-Alcocer J, Pérez-Vives C, Ferrer-Blasco T, López-Gil N, Montés-Micó R (2012) Visual simulation through different intraocular lenses using adaptive optics: effect of tilt and decentration. J Cataract Refract Surg 38(6):947–958PubMedCrossRef Madrid-Costa D, Ruiz-Alcocer J, Pérez-Vives C, Ferrer-Blasco T, López-Gil N, Montés-Micó R (2012) Visual simulation through different intraocular lenses using adaptive optics: effect of tilt and decentration. J Cataract Refract Surg 38(6):947–958PubMedCrossRef
26.
go back to reference Ruiz-Alcocer J, Pérez-Vives C, Madrid-Costa D, López-Gil N, Montés-Micó R (2012) Effect of simulated IOL tilt and decentration on spherical aberration after hyperopic LASIK for different intraocular lenses. J Refract Surg 28:327–334PubMedCrossRef Ruiz-Alcocer J, Pérez-Vives C, Madrid-Costa D, López-Gil N, Montés-Micó R (2012) Effect of simulated IOL tilt and decentration on spherical aberration after hyperopic LASIK for different intraocular lenses. J Refract Surg 28:327–334PubMedCrossRef
Metadata
Title
Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation
Authors
Alberto Domínguez-Vicent
Daniel Monsálvez-Romín
Cari Pérez-Vives
Teresa Ferrer-Blasco
Robert Montés-Micó
Publication date
01-02-2014
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 2/2014
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-013-2509-y

Other articles of this Issue 2/2014

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2014 Go to the issue