Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 2/2024

08-12-2023 | Original Research

Measurement error of pulse pressure variation

Authors: Piet A. H. Wyffels, Stefan De Hert, Patrick F. Wouters

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2024

Login to get access

Abstract

Dynamic preload parameters are used to guide perioperative fluid management. However, reported cut-off values vary and the presence of a gray zone complicates clinical decision making. Measurement error, intrinsic to the calculation of pulse pressure variation (PPV) has not been studied but could contribute to this level of uncertainty. The purpose of this study was to quantify and compare measurement errors associated with PPV calculations. Hemodynamic data of patients undergoing liver transplantation were extracted from the open-access VitalDatabase. Three algorithms were applied to calculate PPV based on 1 min observation periods. For each method, different durations of sampling periods were assessed. Best Linear Unbiased Prediction was determined as the reference PPV-value for each observation period. A Bayesian model was used to determine bias and precision of each method and to simulate the uncertainty of measured PPV-values. All methods were associated with measurement error. The range of differential and proportional bias were [− 0.04%, 1.64%] and [0.92%, 1.17%] respectively. Heteroscedasticity influenced by sampling period was detected in all methods. This resulted in a predicted range of reference PPV-values for a measured PPV of 12% of [10.2%, 13.9%] and [10.3%, 15.1%] for two selected methods. The predicted range in reference PPV-value changes for a measured absolute change of 1% was [− 1.3%, 3.3%] and [− 1.9%, 4%] for these two methods. We showed that all methods that calculate PPV come with varying degrees of uncertainty. Accounting for bias and precision may have important implications for the interpretation of measured PPV-values or PPV-changes.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mlodinow L. The drunkard’s walk: how randomness rules our lives. New York: Pantheon Books; 2008. Mlodinow L. The drunkard’s walk: how randomness rules our lives. New York: Pantheon Books; 2008.
10.
go back to reference Alvarado Sanchez JI, Caicedo Ruiz JD, Diaztagle Fernandez JJ, Cruz Martinez LE, Carreno Hernadez FL,Santacruz Herrera CA, Ospina-Tascon GA . Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis Crit Care 2023; 27(1):361. https://doi.org/10.1186/s13054-023-04629-w Alvarado Sanchez JI, Caicedo Ruiz JD, Diaztagle Fernandez JJ, Cruz Martinez LE, Carreno Hernadez FL,Santacruz Herrera CA, Ospina-Tascon GA . Variables influencing the prediction of fluid responsiveness: a systematic review and meta-analysis Crit Care 2023; 27(1):361. https://​doi.​org/​10.​1186/​s13054-023-04629-w
12.
go back to reference Messina A, Montagnini C, Cammarota G, Giuliani F, Muratore L, Baggiani M, Bennett V, della Corte F, Navalesi P, Cecconi M. Assessment of fluid responsiveness in prone neurosurgical patients undergoing protective ventilation: role of dynamic indices, tidal volume challenge, and end-expiratory occlusion test. Anesth Analg. 2020;130:752–61. https://doi.org/10.1213/ANE.00000000000004494.CrossRefPubMed Messina A, Montagnini C, Cammarota G, Giuliani F, Muratore L, Baggiani M, Bennett V, della Corte F, Navalesi P, Cecconi M. Assessment of fluid responsiveness in prone neurosurgical patients undergoing protective ventilation: role of dynamic indices, tidal volume challenge, and end-expiratory occlusion test. Anesth Analg. 2020;130:752–61. https://​doi.​org/​10.​1213/​ANE.​0000000000000449​4.CrossRefPubMed
Metadata
Title
Measurement error of pulse pressure variation
Authors
Piet A. H. Wyffels
Stefan De Hert
Patrick F. Wouters
Publication date
08-12-2023
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2024
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-023-01099-x

Other articles of this Issue 2/2024

Journal of Clinical Monitoring and Computing 2/2024 Go to the issue

Letter to the editor

Letter to the editor