Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 1/2020

01-01-2020 | Original Article

Maximization of the sealing effect of fibrin glue in aortic surgery

Authors: Masaaki Naganuma, Masatoshi Akiyama, Hiroki Takaya, Kei Sakuma, Kiichiro Kumagai, Shunsuke Kawamoto, Osamu Adachi, Yoshikatsu Saiki

Published in: General Thoracic and Cardiovascular Surgery | Issue 1/2020

Login to get access

Abstract

Objectives

Fibrin glue is used to reinforce anastomosis in aortic surgery. There has not yet been a consensus on how it should be applied optimally. This study aimed to define the optimal condition of applying fibrin glue.

Methods

In experiment 1, we determined the optimal condition for spraying fibrin glue using an expanded polytetrafluoroethylene graft within a needle hole. The length and area of the fibrin cap within the hole were measured. In experiment 2, methods for applying fibrinogen were assessed by comparing brushing and spraying. In experiment 3, swine aorta segments sutured with a Dacron graft were divided into the following three groups: nothing was applied; fibrinogen was sprayed and rubbed using brush. The aorta was clamped and blood was infused from an occlusion catheter inserted into the graft. The pressure at the first appearance of blood leak was recorded.

Results

In experiment 1, among the four groups divided by the pressure and distance of spraying, the fibrin cap area in the group with 0.075 MPa and 2-cm spray distance was significantly larger than that in the group with 0.15 MPa and 2 cm (P < 0.01). In experiment 2, the fibrin cap area in the brushing group was significantly larger than that in the spraying group (P < 0.05). In experiment 3, the capacity to resist endoluminal pressure was higher in the brushing and combined spraying group compared with that in the sequential combined spraying group (P < 0.01).

Conclusions

The brush and spray methods showed excellent hemostatic outcomes.
Literature
1.
go back to reference Matras H, Dinges HP, Lassmann H, Mamoli B. Suture-free interfascicular nerve transplantation in animal experiments. Wien Med Wochenschr. 1972;122:517–23.PubMed Matras H, Dinges HP, Lassmann H, Mamoli B. Suture-free interfascicular nerve transplantation in animal experiments. Wien Med Wochenschr. 1972;122:517–23.PubMed
2.
go back to reference Spängler HP, Braun F, Holle J, Moritz E, Wolner E. The local application of fibrinogen and collagen for hemostasis in heart surgery. Wien Med Wochenschr. 1976;126:86–9.PubMed Spängler HP, Braun F, Holle J, Moritz E, Wolner E. The local application of fibrinogen and collagen for hemostasis in heart surgery. Wien Med Wochenschr. 1976;126:86–9.PubMed
3.
go back to reference Kram HB, Nugent P, Reuben BI, Shoemaker WC. Fibrin glue sealing of polytetrafluoroethylene vascular graft anastomoses: comparison with oxidized cellulose. J Vasc Surg. 1988;8:563–8.CrossRef Kram HB, Nugent P, Reuben BI, Shoemaker WC. Fibrin glue sealing of polytetrafluoroethylene vascular graft anastomoses: comparison with oxidized cellulose. J Vasc Surg. 1988;8:563–8.CrossRef
4.
go back to reference Kheirabadi BS, Pearson R, Rudnicka K, Somwaru L, MacPhee M, Drohan W, et al. Development of an animal model for assessment of the hemostatic efficacy of fibrin sealant in vascular surgery. J Surg Res. 2001;100:84–92.CrossRef Kheirabadi BS, Pearson R, Rudnicka K, Somwaru L, MacPhee M, Drohan W, et al. Development of an animal model for assessment of the hemostatic efficacy of fibrin sealant in vascular surgery. J Surg Res. 2001;100:84–92.CrossRef
5.
go back to reference Seguin JR, Frapier JM, Colson P, Chaptal PA. Fibrin sealant improves surgical results of type A acute aortic dissections. Ann Thorac Surg. 1991;52:745–8 (discussion 8–9).CrossRef Seguin JR, Frapier JM, Colson P, Chaptal PA. Fibrin sealant improves surgical results of type A acute aortic dissections. Ann Thorac Surg. 1991;52:745–8 (discussion 8–9).CrossRef
6.
go back to reference Nakajima T, Kawazoe K, Kataoka T, Kin H, Kazui T, Okabayashi H, et al. Midterm results of aortic repair using a fabric neomedia and fibrin glue for type a acute aortic dissection. Ann Thorac Surg. 2007;83:1615–20.CrossRef Nakajima T, Kawazoe K, Kataoka T, Kin H, Kazui T, Okabayashi H, et al. Midterm results of aortic repair using a fabric neomedia and fibrin glue for type a acute aortic dissection. Ann Thorac Surg. 2007;83:1615–20.CrossRef
7.
go back to reference Minato N, Katayama Y, Yunoki J, Kawasaki H, Satou H. Hemostatic effectiveness of a new application method for fibrin glue, the “rub-and-spray method”, in emergency aortic surgery for acute aortic dissection. Ann Thorac Cardiovasc Surg. 2009;15:265–71.PubMed Minato N, Katayama Y, Yunoki J, Kawasaki H, Satou H. Hemostatic effectiveness of a new application method for fibrin glue, the “rub-and-spray method”, in emergency aortic surgery for acute aortic dissection. Ann Thorac Cardiovasc Surg. 2009;15:265–71.PubMed
8.
go back to reference Rousou JA. Use of fibrin sealants in cardiovascular surgery: a systematic review. J Cardi Surg. 2013;28:238–47.CrossRef Rousou JA. Use of fibrin sealants in cardiovascular surgery: a systematic review. J Cardi Surg. 2013;28:238–47.CrossRef
9.
go back to reference Nakajima S, Fukuda T, Hasue M, Sengoku Y, Haraoka J, Uchida T. New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes. Neurosurgery. 2001;49:117–23.PubMed Nakajima S, Fukuda T, Hasue M, Sengoku Y, Haraoka J, Uchida T. New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes. Neurosurgery. 2001;49:117–23.PubMed
10.
go back to reference Minato N, Shimokawa T, Katayama Y, Yamada N, Sakaguchi M, Itoh M. New application method of fibrin glue for more effective hemostasis in cardiovascular surgery. Jpn J Thorac Cardiovasc Surg. 2004;52:361–6.CrossRef Minato N, Shimokawa T, Katayama Y, Yamada N, Sakaguchi M, Itoh M. New application method of fibrin glue for more effective hemostasis in cardiovascular surgery. Jpn J Thorac Cardiovasc Surg. 2004;52:361–6.CrossRef
Metadata
Title
Maximization of the sealing effect of fibrin glue in aortic surgery
Authors
Masaaki Naganuma
Masatoshi Akiyama
Hiroki Takaya
Kei Sakuma
Kiichiro Kumagai
Shunsuke Kawamoto
Osamu Adachi
Yoshikatsu Saiki
Publication date
01-01-2020
Publisher
Springer Singapore
Published in
General Thoracic and Cardiovascular Surgery / Issue 1/2020
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-019-01155-x

Other articles of this Issue 1/2020

General Thoracic and Cardiovascular Surgery 1/2020 Go to the issue