Abstract

Background

Incisor loss constitutes a strong aesthetic and psychologic traumatism for the patient and it remains a challenging situation for the dental practitioner because of the necessity to rapidly replace the lacking tooth. Various therapeutic procedures have been proposed to replace the incisor concerned, for example by using a removable partial denture. However, the manufacturing of such a denture with classical procedures is often subject to processing errors and inaccuracies. The computer-aided design and computer-aided manufacturing (CAD-CAM) technology could represent a good alternative, but it is currently difficult because of the lack of dental softwares able to design easily immediate removable partial dentures.

Case presentation

A 30-year- patient complained about pain caused by a horizontally and vertically mobile maxillary right central incisor. After all options were presented, extraction of the traumatized incisor was decided due to its very poor prognosis, and the patient selected the realization of a removable denture for economic reasons. The present paper proposes an innovative procedure for immediate removable denture, based on the use of an intraoral scanner, CAD with two different softwares used sequentially, and CAM with a 5-axis machine.

Conclusions

We show in this report that associating an intraoral scanner and CAD-CAM technology can be extended to immediate dentures manufacturing, which could be a valuable procedure for dental practitioners and laboratories, and also for patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sun Q, Chen L, Tian L, Xu B. Single tooth replacement in the anterior arch by means of a cantilevered IPS e.Max Press veneer-retained fixed partial denture: case series of 35 patients. Int J Prosthodont. 2013;26:181–7.CrossRefPubMed Sun Q, Chen L, Tian L, Xu B. Single tooth replacement in the anterior arch by means of a cantilevered IPS e.Max Press veneer-retained fixed partial denture: case series of 35 patients. Int J Prosthodont. 2013;26:181–7.CrossRefPubMed
2.
go back to reference Gooya A, Ejlali M, Adli AR. Fabricating an interim immediate partial denture in one appointment (modified jiffy denture). A clinical report. J Prosthodont. 2013;22(4):330–3.CrossRefPubMed Gooya A, Ejlali M, Adli AR. Fabricating an interim immediate partial denture in one appointment (modified jiffy denture). A clinical report. J Prosthodont. 2013;22(4):330–3.CrossRefPubMed
3.
go back to reference Kang HS, Lee SY. Immediate fixed partial denture after tooth extraction in patients with systemic diseases. A clinical report. J Adv Prosthodont. 2016;8(6):511–4.CrossRefPubMedPubMedCentral Kang HS, Lee SY. Immediate fixed partial denture after tooth extraction in patients with systemic diseases. A clinical report. J Adv Prosthodont. 2016;8(6):511–4.CrossRefPubMedPubMedCentral
4.
go back to reference Campbell SD, Cooper L, Craddock H, Hyde TP, Nattress B, Pavitt SH, Seymour DW. Removable partial dentures: the clinical need for innovation. J Prosthet Dent. 2017;118(3):273–80.CrossRefPubMed Campbell SD, Cooper L, Craddock H, Hyde TP, Nattress B, Pavitt SH, Seymour DW. Removable partial dentures: the clinical need for innovation. J Prosthet Dent. 2017;118(3):273–80.CrossRefPubMed
5.
go back to reference Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 2011;30(1):93–6.CrossRefPubMed Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J. 2011;30(1):93–6.CrossRefPubMed
7.
go back to reference Neumeier TT, Neumeier H. Digital immediate dentures treatment: a clinical report of two patients. J Prosthet Dent. 2016;116(3):314–9.CrossRefPubMed Neumeier TT, Neumeier H. Digital immediate dentures treatment: a clinical report of two patients. J Prosthet Dent. 2016;116(3):314–9.CrossRefPubMed
11.
go back to reference Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano C, Mangano FG. Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study. BMC Oral Health. 2017;17(1):92.CrossRefPubMedPubMedCentral Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano C, Mangano FG. Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study. BMC Oral Health. 2017;17(1):92.CrossRefPubMedPubMedCentral
12.
go back to reference Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, Farges JC, Fages M, Ducret M. Intraoral Scanner Technologies: A Review to Make a Successful Impression. J Healthc Eng. 2017;2017:8427595.CrossRefPubMedPubMedCentral Richert R, Goujat A, Venet L, Viguie G, Viennot S, Robinson P, Farges JC, Fages M, Ducret M. Intraoral Scanner Technologies: A Review to Make a Successful Impression. J Healthc Eng. 2017;2017:8427595.CrossRefPubMedPubMedCentral
13.
go back to reference Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2016;116(2):249–56.CrossRefPubMed Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2016;116(2):249–56.CrossRefPubMed
14.
go back to reference Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109:361–6.CrossRefPubMed Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent. 2013;109:361–6.CrossRefPubMed
16.
go back to reference Haidary A, Leider JS, Silbergleit R. Unsuspected swallowing of a partial denture. AJNR Am J Neuroradiol. 2007;28(9):1734–5.CrossRefPubMed Haidary A, Leider JS, Silbergleit R. Unsuspected swallowing of a partial denture. AJNR Am J Neuroradiol. 2007;28(9):1734–5.CrossRefPubMed
17.
go back to reference Saponaro PC, Yilmaz B, Johnston W, Heshmati RH, McGlumphy EA. Evaluation of patient experience and satisfaction with CAD-CAMfabricated completedentures: A retrospective survey study. J Prosthet Dent. 2016;116(4):524–8.CrossRefPubMed Saponaro PC, Yilmaz B, Johnston W, Heshmati RH, McGlumphy EA. Evaluation of patient experience and satisfaction with CAD-CAMfabricated completedentures: A retrospective survey study. J Prosthet Dent. 2016;116(4):524–8.CrossRefPubMed
18.
go back to reference Joda T, Brägger U. Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial. Clin Oral Implants Res. 2016;27(11):1401–6.CrossRefPubMed Joda T, Brägger U. Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial. Clin Oral Implants Res. 2016;27(11):1401–6.CrossRefPubMed
Metadata
Title
Manufacturing of an immediate removable partial denture with an intraoral scanner and CAD-CAM technology: a case report
Authors
Francois Virard
Laurent Venet
Raphaël Richert
Daniel Pfeffer
Gilbert Viguié
Alexandre Bienfait
Jean-Christophe Farges
Maxime Ducret
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2018
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-018-0578-3

Other articles of this Issue 1/2018

BMC Oral Health 1/2018 Go to the issue