Background

Successful wound healing depends on various factors, including exudate control, prevention of microbial contaminants, and moisture balance. We report two cases of managing burn wounds with SMARTPORE Technology polyurethane foam dressing.

Case presentation

In Case 1, a 2-year-old Asian girl presented with a delayed (11 days) wound on her right leg. She sustained a thermal injury from a hot iron that was left idle on the floor. Clinical inspection revealed an infected wound with overlying eschar that traversed her knee joint. As her parents refused surgical debridement under general anesthesia, hydrotherapy and wound dressing using SMARTPORE Technology Polyurethane foam were used. Despite the delay in presentation of this linear thermal pediatric burn injury that crossed the knee joint, the patient’s response to treatment and its outcome were highly encouraging. She was cooperative and tolerated each dressing change without the need of supplemental analgesia. Her wound was healed by 24 days post-admission. In Case 2, a 25-year-old Asian man presented with a mixed thickness thermal flame burn on his left leg. On examination, the injury was a mix of deep and superficial partial thickness burn, comprising approximately 3 % of his total body surface area. SMARTPORE Technology polyurethane foam was used on his wound; his response to the treatment was very encouraging as the dressing facilitated physiotherapy and mobility. The patient rated the pain during dressing change as 2 on a scale of 10 and his pain score remained the same in every subsequent change. His wound showed evidence of epithelialization by day 7 post-burn. There were no adverse events reported.

Conclusions

Managing burn wounds with SMARTPORE Technology polyurethane foam resulted in reduced pain during dressing changes and the successful healing of partial and mixed thickness wounds. The use of SMARTPORE Technology polyurethane foam dressings showed encouraging results and requires further research as a desirable management option in burn wounds.
Literature
1.
go back to reference Velnar T, Bailey T, Smrkolj V. The wound healing process: an overview of the cellular and molecular mechanisms. J Int Med Res. 2009;37:1528–42.CrossRefPubMed Velnar T, Bailey T, Smrkolj V. The wound healing process: an overview of the cellular and molecular mechanisms. J Int Med Res. 2009;37:1528–42.CrossRefPubMed
3.
go back to reference Thomas HC. Checklist for factors affecting wound healing. Adv Skin Wound Care. 2011;24:192.CrossRef Thomas HC. Checklist for factors affecting wound healing. Adv Skin Wound Care. 2011;24:192.CrossRef
4.
go back to reference Flanagan M. Wound healing and skin integrity: principles and practice. UK: Wiley; 2013. Flanagan M. Wound healing and skin integrity: principles and practice. UK: Wiley; 2013.
5.
go back to reference Brett DW. A review of moisture-control dressings in wound care. J Wound Ostomy Continence Nurs. 2006;33(6 Suppl):S3–8.CrossRefPubMed Brett DW. A review of moisture-control dressings in wound care. J Wound Ostomy Continence Nurs. 2006;33(6 Suppl):S3–8.CrossRefPubMed
6.
go back to reference Upton D, Morgan J, Andrews A, et al. The pain and stress of wound treatment in patients with burns: an international burn specialist perspective. Wounds. 2013;25:199–204.PubMed Upton D, Morgan J, Andrews A, et al. The pain and stress of wound treatment in patients with burns: an international burn specialist perspective. Wounds. 2013;25:199–204.PubMed
7.
go back to reference Medifoam Product Monograph. Seoul: Mundipharma Korea Ltd. Last updated: 2015. Medifoam Product Monograph. Seoul: Mundipharma Korea Ltd. Last updated: 2015.
8.
go back to reference Park YO, Minn KW, Hur JP. The effect of Medifoam (hydrophilic polyurethane foam) dressing in split thickness skin graft donor site. J Korean Soc Plastic Reconstr Surg. 2002;29:297–301. Park YO, Minn KW, Hur JP. The effect of Medifoam (hydrophilic polyurethane foam) dressing in split thickness skin graft donor site. J Korean Soc Plastic Reconstr Surg. 2002;29:297–301.
9.
go back to reference Naude L, Bruwer F. The role of the private nursing practitioner in a multi-disciplinary team. Prof Nurs Today. 2006;10:8–12. Naude L, Bruwer F. The role of the private nursing practitioner in a multi-disciplinary team. Prof Nurs Today. 2006;10:8–12.
Metadata
Title
Managing burn wounds with SMARTPORE Technology polyurethane foam: two case reports
Authors
Farrah-Hani Imran
Rahamah Karim
Noor Hidayah Maat
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Medical Case Reports / Issue 1/2016
Electronic ISSN: 1752-1947
DOI
https://doi.org/10.1186/s13256-016-0918-3

Other articles of this Issue 1/2016

Journal of Medical Case Reports 1/2016 Go to the issue