Skip to main content
Top
Published in:

24-04-2024 | Magnetic Resonance Imaging | Scientific Article

Improved Resolution and Image Quality of Musculoskeletal Magnetic Resonance Imaging using Deep Learning-based Denoising Reconstruction: A Prospective Clinical Study

Authors: Hung P. Do, Carly A. Lockard, Dawn Berkeley, Brian Tymkiw, Nathan Dulude, Scott Tashman, Garry Gold, Jordan Gross, Erin Kelly, Charles P. Ho

Published in: Skeletal Radiology | Issue 12/2024

Login to get access

Abstract

Objective

To prospectively evaluate a deep learning-based denoising reconstruction (DLR) for improved resolution and image quality in musculoskeletal (MSK) magnetic resonance imaging (MRI).

Methods

Images from 137 contrast-weighted sequences in 40 MSK patients were evaluated. Each sequence was performed twice, first with the routine parameters and reconstructed with a routine reconstruction filter (REF), then with higher resolution and reconstructed with DLR, and with three conventional reconstruction filters (NL2, GA43, GA53). The five reconstructions (REF, DLR, NL2, GA43, and GA53) were de-identified, randomized, and blindly reviewed by three MSK radiologists using eight scoring criteria and a forced ranking. Quantitative SNR, CNR, and structure’s full width at half maximum (FWHM) for resolution assessment were measured and compared. To account for repeated measures, Generalized Estimating Equations (GEE) with Bonferroni adjustment was used to compare the reader’s scores, SNR, CNR, and FWHM between DLR vs. NL2, GA43, GA53, and REF.

Results

Compared to the routine REF images, the resolution was improved by 47.61% with DLR from 0.39 ± 0.15 mm2 to 0.20 ± 0.06 mm2 (p < 0.001). Per-sequence average scan time was shortened by 7.93% with DLR from 165.58 ± 21.86 s to 152.45 ± 25.65 s (p < 0.001). Based on the average scores, DLR images were rated significantly higher in all image quality criteria and the forced ranking (p < 0.001).

Conclusion

This prospective clinical evaluation demonstrated that DLR allows approximately two times finer resolution and improved image quality compared to the standard-of-care images.
Appendix
This content is only visible if you are logged in and have the appropriate permissions.
Literature
This content is only visible if you are logged in and have the appropriate permissions.
Metadata
Title
Improved Resolution and Image Quality of Musculoskeletal Magnetic Resonance Imaging using Deep Learning-based Denoising Reconstruction: A Prospective Clinical Study
Authors
Hung P. Do
Carly A. Lockard
Dawn Berkeley
Brian Tymkiw
Nathan Dulude
Scott Tashman
Garry Gold
Jordan Gross
Erin Kelly
Charles P. Ho
Publication date
24-04-2024
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 12/2024
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-024-04679-3

How can your team use biomarkers to improve management of AD? (Link opens in a new window)

Our experts explore using biomarker tests and interpreting results, establishing a shared decision-making approach with patients and caregivers, and applying biomarker testing to guide treatment strategies.

This content is intended for healthcare professionals outside of the UK.

Supported by:
  • Lilly
Developed by: Springer Healthcare IME
Register your interest

How can you integrate PET into your practice? (Link opens in a new window)

1.5 AMA PRA Category 1 Credit(s)™

PET imaging is playing an increasingly critical role in managing AD. Our expert-led program will empower you with practical strategies and real-world case studies to effectively integrate it into clinical practice.

This content is intended for healthcare professionals outside of the UK.

Supported by:
  • Lilly
Developed by: Springer Healthcare IME
Register your interest