01-10-2008 | Laboratory Research

Ablation of High Intensity Focused Ultrasound Combined with SonoVue on Rabbit VX2 Liver Tumors: Assessment with Conventional Gray-Scale US, Conventional Color/Power Doppler US, Contrast-Enhanced Color Doppler US, and Contrast-Enhanced Pulse-Inversion Harmonic US

Authors: Wen Luo, MD, Xiaodong Zhou, MD, Guangbin He, MD, Qiuyang Li, MD, Xiaoying Zheng, MD, Zhiyong Fan, MD, Qing Liu, MD, Ming Yu, MD, Zenghui Han, MD, Jun Zhang, MD, Yunqiu Qian, MD

Published in: Annals of Surgical Oncology | Issue 10/2008

Login to get access

Abstract

Background

We investigated effects of high intensity focused ultrasound (HIFU) combined with contrast agent SonoVue on rabbit VX2 liver tumors by using conventional gray-scale ultrasonography (US), color/power Doppler (CD/PD) US, contrast-enhanced color Doppler (CE CD) US, and contrast-enhanced pulse-inversion harmonic (CE PIH) US.

Methods

Fourteen days after implantation of VX2 tumors in livers of 50 rabbits, animals were randomly separated into two groups. Based on principles of HIFU, the volume of the tumor was divided into several parallel “planes” to be ablated. Before ablation on each “plane,” 0.2 mL SonoVue was injected in bolus via ear veins of rabbits in group II and normal saline solution was administrated in group I. Conventional gray-scale US, CD US, PD US, CE CD US, and CE PIH US were performed before and after ablation.

Results

Twenty-three surviving rabbits in each group underwent HIFU ablation. Conventional gray-scale US showed ablated areas diffusely hyperechoic. On CE PIH US, coagulated areas presented perfusion defect. Both conventional gray-scale US and CE PIH US showed the ablated volume in group II was larger than that in group I. CD US and PD US demonstrated residual vessels in periphery ablated areas in group I, but no residual vessels in group II. CE CD US and CE PIH US depicted less residual vessels in periphery ablated areas in group II than that in group I.

Conclusion

By enlarging ablated volume of tissue and reducing residual vessels, effects of HIFU ablation on rabbit VX2 liver tumors were enhanced by contrast agent SonoVue.
Literature
1.
go back to reference Haar GT, Coussios C. High intensity focused ultrasound: past, present and future. Int J Hyperthermia 2007; 23:85–7PubMedCrossRef Haar GT, Coussios C. High intensity focused ultrasound: past, present and future. Int J Hyperthermia 2007; 23:85–7PubMedCrossRef
2.
go back to reference Leslie TA, Kennedy JE. High intensity focused ultrasound in the treatment of abdominal and gynaecological diseases. Int J Hyperthermia 2007; 23:173–82PubMedCrossRef Leslie TA, Kennedy JE. High intensity focused ultrasound in the treatment of abdominal and gynaecological diseases. Int J Hyperthermia 2007; 23:173–82PubMedCrossRef
3.
go back to reference Klingler HC, Susani M, Seip R, et al. A novel approach to energy ablative therapy of small renal tumours: laparoscopic high-intensity focused ultrasound. Eur Urol 2008; 53:810–8PubMedCrossRef Klingler HC, Susani M, Seip R, et al. A novel approach to energy ablative therapy of small renal tumours: laparoscopic high-intensity focused ultrasound. Eur Urol 2008; 53:810–8PubMedCrossRef
4.
go back to reference Wu F, ter Haar G, Chen WR. High-intensity focused ultrasound ablation of breast cancer. Expert Rev Anticancer Ther 2007; 7:823–31PubMedCrossRef Wu F, ter Haar G, Chen WR. High-intensity focused ultrasound ablation of breast cancer. Expert Rev Anticancer Ther 2007; 7:823–31PubMedCrossRef
5.
go back to reference Zhou XD, Ren XL, Zhang J, et al. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: utility of contrast-enhanced ultrasonography. Eur J Radiol 2007; 62:289–94PubMedCrossRef Zhou XD, Ren XL, Zhang J, et al. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: utility of contrast-enhanced ultrasonography. Eur J Radiol 2007; 62:289–94PubMedCrossRef
6.
go back to reference Wu F, Wang ZB, Chen WZ, et al. Study of a “biological focal region” of high-intensity focused ultrasound. Ultrasound Med Biol 2003; 29:749–54PubMedCrossRef Wu F, Wang ZB, Chen WZ, et al. Study of a “biological focal region” of high-intensity focused ultrasound. Ultrasound Med Biol 2003; 29:749–54PubMedCrossRef
7.
go back to reference Clement GT. Perspectives in clinical uses of high-intensity focused ultrasound. Ultrasonics 2004; 42:1087–93PubMedCrossRef Clement GT. Perspectives in clinical uses of high-intensity focused ultrasound. Ultrasonics 2004; 42:1087–93PubMedCrossRef
8.
go back to reference Haar GT, Coussios C. High intensity focused ultrasound: physical principles and devices. Int J Hyperthermia 2007; 23:89–104PubMedCrossRef Haar GT, Coussios C. High intensity focused ultrasound: physical principles and devices. Int J Hyperthermia 2007; 23:89–104PubMedCrossRef
9.
go back to reference Kennedy JE, Ter Haar GR, Cranston D. High intensity focused ultrasound: surgery of the future? Br J Radiol 2003; 76:590–9PubMedCrossRef Kennedy JE, Ter Haar GR, Cranston D. High intensity focused ultrasound: surgery of the future? Br J Radiol 2003; 76:590–9PubMedCrossRef
10.
go back to reference Luo W, Zhou X, Tian X, et al. Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation. Adv Ther 2006; 23:861–8PubMedCrossRef Luo W, Zhou X, Tian X, et al. Enhancement of ultrasound contrast agent in high-intensity focused ultrasound ablation. Adv Ther 2006; 23:861–8PubMedCrossRef
11.
go back to reference Hariharan P, Myers MR, Banerjee RK. HIFU procedures at moderate intensities—effect of large blood vessels. Phys Med Biol 2007; 52:3493–513PubMedCrossRef Hariharan P, Myers MR, Banerjee RK. HIFU procedures at moderate intensities—effect of large blood vessels. Phys Med Biol 2007; 52:3493–513PubMedCrossRef
12.
go back to reference Huang J, Holt RG, Cleveland RO, et al. Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms. J Acoust Soc Am 2004; 116:2451–8PubMedCrossRef Huang J, Holt RG, Cleveland RO, et al. Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms. J Acoust Soc Am 2004; 116:2451–8PubMedCrossRef
13.
go back to reference Wu F, Wang ZB, Chen WZ, et al. Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma. Ann Surg Oncol 2004; 11:1061–9PubMedCrossRef Wu F, Wang ZB, Chen WZ, et al. Extracorporeal high intensity focused ultrasound ablation in the treatment of patients with large hepatocellular carcinoma. Ann Surg Oncol 2004; 11:1061–9PubMedCrossRef
14.
go back to reference Li JJ, Xu GL, Gu MF, et al. Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors. World J Gastroenterol. 2007; 21:2747–51 Li JJ, Xu GL, Gu MF, et al. Complications of high intensity focused ultrasound in patients with recurrent and metastatic abdominal tumors. World J Gastroenterol. 2007; 21:2747–51
15.
go back to reference Li YY, Sha WH, Zhou YJ, et al. Short and long term efficacy of high intensity focused ultrasound therapy for advanced hepatocellular carcinoma. J Gastroenterol Hepatol 2007; 22:2148–54PubMedCrossRef Li YY, Sha WH, Zhou YJ, et al. Short and long term efficacy of high intensity focused ultrasound therapy for advanced hepatocellular carcinoma. J Gastroenterol Hepatol 2007; 22:2148–54PubMedCrossRef
16.
go back to reference Wu F, Wang ZB, Chen WZ, et al. Advanced hepatocellular carcinoma: treatment with high intensity focused ultrasound ablation combined with transcatheter arterial embolization. Radiology 2005; 235:659–67PubMedCrossRef Wu F, Wang ZB, Chen WZ, et al. Advanced hepatocellular carcinoma: treatment with high intensity focused ultrasound ablation combined with transcatheter arterial embolization. Radiology 2005; 235:659–67PubMedCrossRef
17.
go back to reference Tung YS, Liu HL, Wu CC, et al. Contrast-agent-enhanced ultrasound thermal ablation. Ultrasound Med Biol 2006; 32:1103–10PubMedCrossRef Tung YS, Liu HL, Wu CC, et al. Contrast-agent-enhanced ultrasound thermal ablation. Ultrasound Med Biol 2006; 32:1103–10PubMedCrossRef
18.
go back to reference Takegami K, Kaneko Y, Watanabe T, et al. Erythrocytes, as well as microbubble contrast agents, are important factors in improving thermal and therapeutic effects of high-intensity focused ultrasound. Ultrasound Med Biol 2005; 31:385–90PubMedCrossRef Takegami K, Kaneko Y, Watanabe T, et al. Erythrocytes, as well as microbubble contrast agents, are important factors in improving thermal and therapeutic effects of high-intensity focused ultrasound. Ultrasound Med Biol 2005; 31:385–90PubMedCrossRef
19.
go back to reference Melodelima D, N’Djin WA, Parmentier H, et al. Toric HIFU transducer for large thermal ablation. Conf Proc IEEE Eng Med Biol Soc 2007; 2007:230–3PubMed Melodelima D, N’Djin WA, Parmentier H, et al. Toric HIFU transducer for large thermal ablation. Conf Proc IEEE Eng Med Biol Soc 2007; 2007:230–3PubMed
20.
21.
go back to reference Dai Y, Chen MH, Yin SS, et al. Focal liver lesions: can SonoVue-enhanced ultrasound be used to differentiate malignant from benign lesions? Invest Radiol 2007; 42:596–603PubMedCrossRef Dai Y, Chen MH, Yin SS, et al. Focal liver lesions: can SonoVue-enhanced ultrasound be used to differentiate malignant from benign lesions? Invest Radiol 2007; 42:596–603PubMedCrossRef
22.
go back to reference Luo W, Zhou X, Gong X, et al. Study of sequential histopathologic changes, apoptosis, and cell proliferation in rabbit livers after high-intensity focused ultrasound ablation. J Ultrasound Med 2007; 26:477–85PubMed Luo W, Zhou X, Gong X, et al. Study of sequential histopathologic changes, apoptosis, and cell proliferation in rabbit livers after high-intensity focused ultrasound ablation. J Ultrasound Med 2007; 26:477–85PubMed
23.
go back to reference Luo W, Zhou X, Zhang J, et al. Analysis of apoptosis and cell proliferation after high intensity-focused ultrasound ablation combined with microbubbles in rabbit livers. Eur J Gastroenterol Hepatol 2007; 19:962–8PubMedCrossRef Luo W, Zhou X, Zhang J, et al. Analysis of apoptosis and cell proliferation after high intensity-focused ultrasound ablation combined with microbubbles in rabbit livers. Eur J Gastroenterol Hepatol 2007; 19:962–8PubMedCrossRef
24.
go back to reference Takegami K, Kaneko Y, Watanabe T, et al. Heating and coagulation volume obtained with high-intensity focused ultrasound therapy: comparison of perflutren protein-type A microspheres and MRX-133 in rabbits. Radiology 2005; 237:132–6PubMedCrossRef Takegami K, Kaneko Y, Watanabe T, et al. Heating and coagulation volume obtained with high-intensity focused ultrasound therapy: comparison of perflutren protein-type A microspheres and MRX-133 in rabbits. Radiology 2005; 237:132–6PubMedCrossRef
25.
go back to reference Hanajiri K, Maruyama T, Kaneko Y, et al. Microbubble-induced increase in ablation of liver tumors by high-intensity focused ultrasound. Hepatol Res 2006; 36:308–14PubMedCrossRef Hanajiri K, Maruyama T, Kaneko Y, et al. Microbubble-induced increase in ablation of liver tumors by high-intensity focused ultrasound. Hepatol Res 2006; 36:308–14PubMedCrossRef
26.
go back to reference Kaneko Y, Maruyama T, Takegami K, et al. Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue. Eur Radiol 2005; 15:1415–20PubMedCrossRef Kaneko Y, Maruyama T, Takegami K, et al. Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue. Eur Radiol 2005; 15:1415–20PubMedCrossRef
27.
go back to reference Yu T, Xiong S, Mason TJ, et al. The use of a micro-bubble agent to enhance rabbit liver destruction using high intensity focused ultrasound. Ultrason Sonochem 2006; 13:143–9PubMedCrossRef Yu T, Xiong S, Mason TJ, et al. The use of a micro-bubble agent to enhance rabbit liver destruction using high intensity focused ultrasound. Ultrason Sonochem 2006; 13:143–9PubMedCrossRef
28.
go back to reference Luo W, Zhou X, Ren X, et al. Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo. J Ultrasound Med 2007; 26:469–76PubMed Luo W, Zhou X, Ren X, et al. Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo. J Ultrasound Med 2007; 26:469–76PubMed
29.
go back to reference Li CX, Xu GL, Jiang ZY, et al. Analysis of clinical effect of high-intensity focused ultrasound on liver cancer. World J Gastroenterol 2004; 10:2201–4PubMed Li CX, Xu GL, Jiang ZY, et al. Analysis of clinical effect of high-intensity focused ultrasound on liver cancer. World J Gastroenterol 2004; 10:2201–4PubMed
30.
go back to reference Rabkin BA, Zderic V, Crum LA, et al. Biological and physical mechanisms of HIFU-induced hyperecho in ultrasound images. Ultrasound Med Biol 2006; 32:1721–9PubMedCrossRef Rabkin BA, Zderic V, Crum LA, et al. Biological and physical mechanisms of HIFU-induced hyperecho in ultrasound images. Ultrasound Med Biol 2006; 32:1721–9PubMedCrossRef
31.
go back to reference Rabkin BA, Zderic V, Vaezy S. Hyperecho in ultrasound images of HIFU therapy: involvement of cavitation. Ultrasound Med Biol 2005; 31:947–56PubMedCrossRef Rabkin BA, Zderic V, Vaezy S. Hyperecho in ultrasound images of HIFU therapy: involvement of cavitation. Ultrasound Med Biol 2005; 31:947–56PubMedCrossRef
32.
go back to reference Kisaka Y, Hirooka M, Kumagi T, et al. Usefulness of contrast-enhanced ultrasonography with abdominal virtual ultrasonography in assessing therapeutic response in hepatocellular carcinoma treated with radiofrequency ablation. Liver Int 2006; 26:1241–7PubMedCrossRef Kisaka Y, Hirooka M, Kumagi T, et al. Usefulness of contrast-enhanced ultrasonography with abdominal virtual ultrasonography in assessing therapeutic response in hepatocellular carcinoma treated with radiofrequency ablation. Liver Int 2006; 26:1241–7PubMedCrossRef
33.
go back to reference Vilana R, Bianchi L, Varela M, et al. Is microbubble-enhanced ultrasonography sufficient for assessment of response to percutaneous treatment in patients with early hepatocellular carcinoma? Eur Radiol 2006; 16:2454–62PubMedCrossRef Vilana R, Bianchi L, Varela M, et al. Is microbubble-enhanced ultrasonography sufficient for assessment of response to percutaneous treatment in patients with early hepatocellular carcinoma? Eur Radiol 2006; 16:2454–62PubMedCrossRef
34.
go back to reference Holt RG, Roy RA. Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. Ultrasound Med Biol 2001; 7:1399–412CrossRef Holt RG, Roy RA. Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. Ultrasound Med Biol 2001; 7:1399–412CrossRef
Metadata
Title
Ablation of High Intensity Focused Ultrasound Combined with SonoVue on Rabbit VX2 Liver Tumors: Assessment with Conventional Gray-Scale US, Conventional Color/Power Doppler US, Contrast-Enhanced Color Doppler US, and Contrast-Enhanced Pulse-Inversion Harmonic US
Authors
Wen Luo, MD
Xiaodong Zhou, MD
Guangbin He, MD
Qiuyang Li, MD
Xiaoying Zheng, MD
Zhiyong Fan, MD
Qing Liu, MD
Ming Yu, MD
Zenghui Han, MD
Jun Zhang, MD
Yunqiu Qian, MD
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
Annals of Surgical Oncology / Issue 10/2008
Print ISSN: 1068-9265
Electronic ISSN: 1534-4681
DOI
https://doi.org/10.1245/s10434-008-0032-x

Other articles of this Issue 10/2008

Annals of Surgical Oncology 10/2008 Go to the issue