Skip to main content
Top
Published in: Annals of Surgical Oncology 2/2005

01-02-2005

Stereotactic Radioguided Surgery by SiteSelect for Subclinical Mammographic Lesions

Authors: Virginie Doridot, MD, Martine Meunier, MD, Carl El Khoury, MD, Claude Nos, MD, Anne Vincent-Salomon, MD, Brigitte Sigal-Zafrani, MD, Krishna B. Clough, MD

Published in: Annals of Surgical Oncology | Issue 2/2005

Login to get access

Abstract

Background

We defined the indications for and evaluated the results of a new technique for radioguided surgery, the SiteSelect system. The procedure allows en-bloc resection of the breast parenchyma under local anesthesia.

Methods

This prospective study was based on 167 patients operated on between December 2000 and October 2003 with 2 phases. The first step was an evaluation of the feasibility of the procedure with the 15-mm cannula, and the second was therapeutic with the 22-mm cannula.

Results

The mean duration of the procedure was 42 minutes. In 96.9% of procedures, the lesion was excised successfully. Only one complication (hematoma) and two failures and were observed. Histological examination revealed benign disease in 65.8% of cases and cancer in 34.2% of cases. In the latter cases, the specimen margins were histologically involved in 86.2% of cases with the 15-mm procedure and in 41% with the 22-mm procedure. During the first evaluation, all patients with a cancer underwent systematic surgical re-excision: residual tumor was present in 18 cases (64.2%). The biopsy was painless for 88 patients, and the cosmetic result was good in all cases.

Conclusions

This study shows that the SiteSelect procedure allows resection of the lesion in 96.9% of cases. Combined with complementary surgical lumpectomy during the same operation, this procedure achieved a success rate of 98.7%. In the case of cancer, the 15-mm cannula is not wide enough to allow free margins. The use of a new 22-mm cannula, currently under evaluation, might solve this problem.
Appendix
Available only for authorised users
Literature
1.
go back to reference Parker, SH, Lovin, JD, Jobe, WE, et al. 1990Stereotactic breast biopsy with a gunRadiology1767417PubMed Parker, SH, Lovin, JD, Jobe, WE,  et al. 1990Stereotactic breast biopsy with a gunRadiology1767417PubMed
2.
go back to reference Parker, SH, Lovin, JD, Jobe, WE, Burke, BJ, Hopper, KD, Yakes, WF 1991Non palpable breast lesions: stereotactic automated large-core biopsiesRadiology1804037PubMed Parker, SH, Lovin, JD, Jobe, WE, Burke, BJ, Hopper, KD, Yakes, WF 1991Non palpable breast lesions: stereotactic automated large-core biopsiesRadiology1804037PubMed
3.
go back to reference Burbank, F 1997Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsiesRadiology2041536PubMed Burbank, F 1997Mammographic findings after 14-gauge automated needle and 14-gauge directional, vacuum-assisted stereotactic breast biopsiesRadiology2041536PubMed
4.
go back to reference Liberman, L, Dershow, DD, Morris, EA, Abramson, AF, Thornton, CM, Rosen, PP 1997Clip placement after stereotactic vacuum-assisted breast biopsyRadiology20541722PubMed Liberman, L, Dershow, DD, Morris, EA, Abramson, AF, Thornton, CM, Rosen, PP 1997Clip placement after stereotactic vacuum-assisted breast biopsyRadiology20541722PubMed
5.
go back to reference Burbank, F, Parker, SH 1998Methods for evaluating the quality of an image-guided breast biopsy programSemin Breast Dis17183 Burbank, F, Parker, SH 1998Methods for evaluating the quality of an image-guided breast biopsy programSemin Breast Dis17183
6.
go back to reference Jackman, RJ, Burbank, F, Parker, SH, et al. 2001Stereotactic breast biopsy of non palpable lesions: determinants of ductal carcinoma in situ underestimation ratesRadiology218497502PubMed Jackman, RJ, Burbank, F, Parker, SH,  et al. 2001Stereotactic breast biopsy of non palpable lesions: determinants of ductal carcinoma in situ underestimation ratesRadiology218497502PubMed
7.
go back to reference Lifrange, E, Dondelinger, RF, Fridman, V, Colin, C 2001En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?Eur Radiol11796801PubMed Lifrange, E, Dondelinger, RF, Fridman, V, Colin, C 2001En bloc excision of nonpalpable breast lesions using the advanced breast biopsy instrumentation system: an alternative to needle guided surgery?Eur Radiol11796801PubMed
8.
go back to reference Marti, WR, Zuber, M, Oertli, D, et al. 2001Advanced breast biopsy instrumentation for the evaluation of impalpable lesions: a reliable diagnostic tool with little therapeutic potentialEur J Surg167158PubMed Marti, WR, Zuber, M, Oertli, D,  et al. 2001Advanced breast biopsy instrumentation for the evaluation of impalpable lesions: a reliable diagnostic tool with little therapeutic potentialEur J Surg167158PubMed
9.
go back to reference Vargas, HI, Agbunag, RV, Khaikhali, I 2000State of the art of minimally invasive breast biopsy: principles and practiceBreast Cancer73709PubMedCrossRef Vargas, HI, Agbunag, RV, Khaikhali, I 2000State of the art of minimally invasive breast biopsy: principles and practiceBreast Cancer73709PubMedCrossRef
10.
go back to reference Atallah, N, Karam, R, Younane, T, Aftimos, G 2000Stereotaxic excisional biopsy of non-palpable breast lesions by the ABBI (Advanced Breast Biopsy Instrumentation) technique. Advantages. Disadvantages. Indications. Apropos of 67 casesJ Med Liban48706PubMed Atallah, N, Karam, R, Younane, T, Aftimos, G 2000Stereotaxic excisional biopsy of non-palpable breast lesions by the ABBI (Advanced Breast Biopsy Instrumentation) technique. Advantages. Disadvantages. Indications. Apropos of 67 casesJ Med Liban48706PubMed
11.
go back to reference Smathers, RL 2000Advanced breast biopsy instrumentation device: percentages of lesion and surrounding tissue removedAJR Am J Roentgenol1758013PubMed Smathers, RL 2000Advanced breast biopsy instrumentation device: percentages of lesion and surrounding tissue removedAJR Am J Roentgenol1758013PubMed
12.
go back to reference Schwartzberg, BS, Goates, JJ, Keeler, SA, Moore, JA 2000Use of advanced breast biopsy instrumentation while performing stereotactic breast biopsies: review of 150 consecutive biopsiesJ Am Coll Surg191915PubMed Schwartzberg, BS, Goates, JJ, Keeler, SA, Moore, JA 2000Use of advanced breast biopsy instrumentation while performing stereotactic breast biopsies: review of 150 consecutive biopsiesJ Am Coll Surg191915PubMed
13.
go back to reference Lifrange, E, Colin, C 2000Supraconservative breast surgeryJ Gynecol Obstet Biol Reprod292857 Lifrange, E, Colin, C 2000Supraconservative breast surgeryJ Gynecol Obstet Biol Reprod292857
14.
go back to reference Ferzli, GS, Puza, T, Vanvorst-Bilotti, S, Waters, R 1999Breast biopsies with ABBI(R): experience with 183 attempted biopsiesBreast J5268PubMed Ferzli, GS, Puza, T, Vanvorst-Bilotti, S, Waters, R 1999Breast biopsies with ABBI(R): experience with 183 attempted biopsiesBreast J5268PubMed
15.
go back to reference Denton, ER, Michell, MJ, Wilson, AR, Britton, P 1999Stereotactic excisional breast biopsy performed by interventional radiologists using the ABBI systemBr J Radiol728289PubMed Denton, ER, Michell, MJ, Wilson, AR, Britton, P 1999Stereotactic excisional breast biopsy performed by interventional radiologists using the ABBI systemBr J Radiol728289PubMed
16.
go back to reference Velanovich, V, Lewis, FR,Jr, Nathanson, SD, et al. 1999Comparison of mammographically guided breast biopsy techniquesAnn Surg22962530PubMed Velanovich, V, Lewis, FR,Jr, Nathanson, SD,  et al. 1999Comparison of mammographically guided breast biopsy techniquesAnn Surg22962530PubMed
17.
go back to reference Leibman, AJ, Frager, D, Choi, P 1999Experience with breast biopsies using the Advanced Breast Biopsy Instrumentation systemAJR Am J Roentgenol172140912PubMed Leibman, AJ, Frager, D, Choi, P 1999Experience with breast biopsies using the Advanced Breast Biopsy Instrumentation systemAJR Am J Roentgenol172140912PubMed
18.
go back to reference Damascelli, B, Frigerio, LF, Lanocita, R, et al. 1998Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation systemBr J Radiol71100311PubMed Damascelli, B, Frigerio, LF, Lanocita, R,  et al. 1998Stereotactic excisional breast biopsy performed by interventional radiologists using the advanced breast biopsy instrumentation systemBr J Radiol71100311PubMed
19.
go back to reference Bloomston, M, D’Angelo, P, Galliano, D, Butler, J,Jr, Dean, R, Rosemurgy, AS 1999One hundred consecutive advanced breast biopsy instrumentation procedures: complications, costs, and outcomeAnn Surg Oncol61959PubMed Bloomston, M, D’Angelo, P, Galliano, D, Butler, J,Jr, Dean, R, Rosemurgy, AS 1999One hundred consecutive advanced breast biopsy instrumentation procedures: complications, costs, and outcomeAnn Surg Oncol61959PubMed
20.
go back to reference Jackman, RJ, Burbank, F, Parker, SH, et al. 1997Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted breast biopsyRadiology2044858PubMed Jackman, RJ, Burbank, F, Parker, SH,  et al. 1997Atypical ductal hyperplasia diagnosed at stereotactic breast biopsy: improved reliability with 14-gauge, directional, vacuum-assisted breast biopsyRadiology2044858PubMed
21.
go back to reference Corn, CC 2003Review of 125 SiteSelect stereotactic large-core breast biopsy proceduresBreast J914752PubMed Corn, CC 2003Review of 125 SiteSelect stereotactic large-core breast biopsy proceduresBreast J914752PubMed
22.
go back to reference Rebner, M, Chesbrough, R, Gregory, N 1999Initial experience with the advanced breast biopsy instrumentation deviceAJR Am J Roentgenol1732216PubMed Rebner, M, Chesbrough, R, Gregory, N 1999Initial experience with the advanced breast biopsy instrumentation deviceAJR Am J Roentgenol1732216PubMed
23.
go back to reference Parker, SH 1998The Advanced Breast Biopsy Instrumentation: another Trojan horse? AJR Am J Roentgenol171513PubMed Parker, SH 1998The Advanced Breast Biopsy Instrumentation: another Trojan horse? AJR Am J Roentgenol171513PubMed
24.
go back to reference Singlebarry, SE, Fornage, BD, Sneige, N, et al. 2002Radiofrequency ablation of early-stage invasive breast tumors: an overviewCancer J817780CrossRef Singlebarry, SE, Fornage, BD, Sneige, N,  et al. 2002Radiofrequency ablation of early-stage invasive breast tumors: an overviewCancer J817780CrossRef
25.
go back to reference Izzo, F, Thomas, R, Delrio, P, et al. 2001Radiofrequency ablation in patients with primary breast carcinoma: a pilot study in 26 patientsCancer92203644CrossRefPubMed Izzo, F, Thomas, R, Delrio, P,  et al. 2001Radiofrequency ablation in patients with primary breast carcinoma: a pilot study in 26 patientsCancer92203644CrossRefPubMed
Metadata
Title
Stereotactic Radioguided Surgery by SiteSelect for Subclinical Mammographic Lesions
Authors
Virginie Doridot, MD
Martine Meunier, MD
Carl El Khoury, MD
Claude Nos, MD
Anne Vincent-Salomon, MD
Brigitte Sigal-Zafrani, MD
Krishna B. Clough, MD
Publication date
01-02-2005
Publisher
Springer-Verlag
Published in
Annals of Surgical Oncology / Issue 2/2005
Print ISSN: 1068-9265
Electronic ISSN: 1534-4681
DOI
https://doi.org/10.1245/ASO.2005.01.004

Other articles of this Issue 2/2005

Annals of Surgical Oncology 2/2005 Go to the issue